Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Surgery

Aged

2007

Articles 1 - 3 of 3

Full-Text Articles in Medicine and Health Sciences

Comparison Of Eight Prosthetic Aortic Valves In A Cadaver Model., Benjamin A. Youdelman, Hitoshi Hirose, Harsh Jain, J Yasha Kresh, John W.C. Entwistle, Andrew S. Wechsler Dec 2007

Comparison Of Eight Prosthetic Aortic Valves In A Cadaver Model., Benjamin A. Youdelman, Hitoshi Hirose, Harsh Jain, J Yasha Kresh, John W.C. Entwistle, Andrew S. Wechsler

Department of Surgery Faculty Papers

OBJECTIVES: Proper valve selection is critical to ensure appropriate valve replacement for patients, because implantation of a small valve might place the patient at risk for persistent gradients. Labeled valve size is not the same as millimeter measure of prosthetic valve diameters or the annulus into which it will fit. Studies that use the labeled valve size in lieu of actual measured diameter in millimeters to compare different valves might be misleading. Using human cadaver hearts, we sized the aortic annulus with 8 commonly used prosthetic aortic valve sizers and compared the valves using geometric orifice area. This novel method …


Comparison Of Eight Prosthetic Aortic Valves In A Cadaver Model, Benjamin A. Youdelman, Hitoshi Hirose, Harsh Jain, J. Yasha Kresh, John W.C. Entwhistle Iii, Andrew S. Wechsler Jul 2007

Comparison Of Eight Prosthetic Aortic Valves In A Cadaver Model, Benjamin A. Youdelman, Hitoshi Hirose, Harsh Jain, J. Yasha Kresh, John W.C. Entwhistle Iii, Andrew S. Wechsler

Department of Surgery Faculty Papers

OBJECTIVES: Proper valve selection is critical to ensure appropriate valve replacement for patients, because implantation of a small valve might place the patient at risk for persistent gradients. Labeled valve size is not the same as millimeter measure of prosthetic valve diameters or the annulus into which it will fit. Studies that use the labeled valve size in lieu of actual measured diameter in millimeters to compare different valves might be misleading. Using human cadaver hearts, we sized the aortic annulus with 8 commonly used prosthetic aortic valve sizers and compared the valves using geometric orifice area. This novel method …


Role Of Immediate Reconstruction For Elderly Breast Cancer Patients, Anne L. Rosenburg, Kristin L. Brill, R. A. Flynn, Steven E. Copit Jun 2007

Role Of Immediate Reconstruction For Elderly Breast Cancer Patients, Anne L. Rosenburg, Kristin L. Brill, R. A. Flynn, Steven E. Copit

Department of Surgery Faculty Papers

With rising numbers of elderly women developing breast cancer, treatment options must evolve which take into consideration quality of life and functional status. Although fewer women at all ages are undergoing mastectomy, for those elderly women who undergo mastectomy, reconstruction options should be offered. Over the past 5 years, increasing numbers of elderly women are electing immediate reconstruction (IM).