Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Physics

Articles

Partial Least Squares Regression

Publication Year

Articles 1 - 2 of 2

Full-Text Articles in Medicine and Health Sciences

Ultra-Filtration Of Human Serum For Improved Quantitative Analysis Of Low Molecular Weight Biomarkers Using Atr-Ir Spectroscopy, Franck Bonnier, Luis Felipe Cs. Carvalho, Matthew J. Baker, Hugh Byrne, Igor Chourpa Jun 2017

Ultra-Filtration Of Human Serum For Improved Quantitative Analysis Of Low Molecular Weight Biomarkers Using Atr-Ir Spectroscopy, Franck Bonnier, Luis Felipe Cs. Carvalho, Matthew J. Baker, Hugh Byrne, Igor Chourpa

Articles

Infrared spectroscopy is a reliable, rapid and cost effective characterisation technique, delivering a molecular finger print of the sample. It is expected that its sensitivity would enable detection of small chemical variations in biological samples associated with disease. ATR-IR is particularly suitable for liquid sample analysis and, although air drying is commonly performed before data collection, just a drop of human serum is enough for screening and early diagnosis. However, the dynamic range of constituent biochemical concentrations in the serum composition remains a limiting factor to the reliability of the technique. Using glucose as a model spike in human serum, …


Quantitative Reagent-Free Detection Of Fibrinogen Levels In Human Blood Plasma Using Raman Spectroscopy, Kelvin Poon, Fiona Lyng, Peter Knief, Orla L. Howe, Aidan Meade, James Curtin, Hugh Byrne, Joseph Vaughan Jan 2012

Quantitative Reagent-Free Detection Of Fibrinogen Levels In Human Blood Plasma Using Raman Spectroscopy, Kelvin Poon, Fiona Lyng, Peter Knief, Orla L. Howe, Aidan Meade, James Curtin, Hugh Byrne, Joseph Vaughan

Articles

Fibrinogen assays are commonly used as part of clinical screening tests to investigate haemorrhagic states, for detection of disseminated intravascular coagulation and as a predictor of a variety of cardiovascular events. The Clauss assay, which measures thrombin clotting time, is the most commonly used method for measuring fibrinogen levels. Nevertheless, inconsistencies are present in inter-manufacturer reagent sources, calibration standards and methodologies. Automated coagulation analysers, which measure changes in optical density during the prothrombin time (PT-Fg), have found use in many hospitals. However, the PT-Fg method is found to give falsely elevated values due to varying choices of calibrants, reagents and …