Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 1 of 1
Full-Text Articles in Medicine and Health Sciences
Isolated Polyethylene Exchange Versus Acetabular Revision For Polyethylene Wear, Camilo Restrepo, Elie Ghanem, Carrie Houssock, Mathew Austin, Javad Parvizi, William J. Hozack
Isolated Polyethylene Exchange Versus Acetabular Revision For Polyethylene Wear, Camilo Restrepo, Elie Ghanem, Carrie Houssock, Mathew Austin, Javad Parvizi, William J. Hozack
Department of Orthopaedic Surgery Faculty Papers
Polyethylene wear and osteolysis are not uncommon in THA mid- and long-term. In asymptomatic patients the dilemma faced by the orthopaedic surgeon is whether to revise the cup and risk damage to the supporting columns and even pelvic discontinuity or to perform isolated polyethylene exchange and risk a high rate of postoperative recurrent instability and dislocation that will necessitate further surgery. We retrospectively reviewed 62 patients (67 hips) who underwent revision arthroplasty for polywear and osteolysis. Thirty-six hips had isolated polyethylene exchange, while 31 had full acetabular revision. The minimum followup was 2 years (mean, 2.8 years; range, 2-5 years). …