Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Medicine and Health Sciences

The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk Oct 2009

The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk

Oncology Publications

Cone-beam computed tomography (CBCT) is used for patient alignment before treatment and is ideal for use in adaptive radiotherapy to account for tumor shrinkage, organ deformation and weight loss. However, CBCT images are prone to artifacts such as streaking and cupping effects, reducing image quality and CT number accuracy. Our goal was to determine the optimum combination of cone-beam imaging options to increase the accuracy of image CT numbers. Several phantoms with and without inserts of known relative electron densities were imaged using the Varian on-board imaging system. It was found that CT numbers are most influenced by the selection …


Dosimetric Evaluation Of Heterogeneity Corrections For Rtog 0236: Stereotactic Body Radiotherapy Of Inoperable Stage I-Ii Non-Small-Cell Lung Cancer., Ying Xiao, Lech Papiez, Rebecca Paulus, Robert Timmerman, William L. Straube, Walter R. Bosch, Jeff Michalski, James M. Galvin Mar 2009

Dosimetric Evaluation Of Heterogeneity Corrections For Rtog 0236: Stereotactic Body Radiotherapy Of Inoperable Stage I-Ii Non-Small-Cell Lung Cancer., Ying Xiao, Lech Papiez, Rebecca Paulus, Robert Timmerman, William L. Straube, Walter R. Bosch, Jeff Michalski, James M. Galvin

Department of Radiation Oncology Faculty Papers

PURPOSE: Using a retrospective analysis of treatment plans submitted from multiple institutions accruing patients to the Radiation Therapy Oncology Group (RTOG) 0236 non-small-cell stereotactic body radiotherapy protocol, the present study determined the dose prescription and critical structure constraints for future stereotactic body radiotherapy lung protocols that mandate density-corrected dose calculations.

METHOD AND MATERIALS: A subset of 20 patients from four institutions participating in the RTOG 0236 protocol and using superposition/convolution algorithms were compared. The RTOG 0236 protocol required a prescription dose of 60 Gy delivered in three fractions to cover 95% of the planning target volume. Additional requirements were specified …


The Use Of Ct Density Changes At Internal Tissue Interfaces To Correlate Internal Organ Motion With An External Surrogate, Stewart Gaede, Gregory Carnes, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee Jan 2009

The Use Of Ct Density Changes At Internal Tissue Interfaces To Correlate Internal Organ Motion With An External Surrogate, Stewart Gaede, Gregory Carnes, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee

Edward Yu

The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing …


Adaptive Radiation Therapy For Localized Mesothelioma With Mediastinal Metastasis Using Helical Tomotherapy., James Renaud, Slav Yartsev, A Rashid Dar, Jacob Van Dyk Jan 2009

Adaptive Radiation Therapy For Localized Mesothelioma With Mediastinal Metastasis Using Helical Tomotherapy., James Renaud, Slav Yartsev, A Rashid Dar, Jacob Van Dyk

Oncology Publications

The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The …