Validation Of A Respiratory Gating System For Automated Delivery Of The Deep Inspiration Breath-Hold Technique, Michael G. Stock May 2021

Validation Of A Respiratory Gating System For Automated Delivery Of The Deep Inspiration Breath-Hold Technique, Michael G. Stock

LSU Master's Theses

Purpose: To validate the performance of a respiratory gating system for the automated delivery of the deep inspiration breath-hold (DIBH) technique.

Methods: The gating system utilized an automatic gating interface (Elekta Response) which connected a marker-based respiratory motion monitoring system to the linear accelerator control system. The gating system was characterized dosimetrically and temporally using two distinct approaches. Central-axis output and energy constancy were evaluated across 8 beam-matched linear accelerators. Additionally, a representative set of 5 treatment plans were delivered both non-gated and gated to a 2D diode array (MapCHECK). The respiratory motion monitoring system optically tracked a reflective marker …


Infection Potential Of Rickettsia Felis Via Ingestion, Matthew M. Schexnayder Jul 2019

Infection Potential Of Rickettsia Felis Via Ingestion, Matthew M. Schexnayder

LSU Master's Theses

Rickettsia felis is the etiologic agent of flea-borne spotted fever (FBSF) in humans and a poorly described cause of fever in animals. It is transmitted by its primary arthropod vector and reservoir host, the cat flea Ctenocephalides felis. Known routes of Rickettsia felis transmission between Rickettsia felis-infected cat fleas and vertebrate hosts include cutaneous bites and contamination of cutaneous wounds with infective flea feces. The bulk of FBSF infections occur in young children in Africa, though infections of people at all ages all over the world have been confirmed. As mammals and young children frequently come into contact …


Scintillation Event Localization In Novel Hemi-Ellipsoid Detector For Spect, Hanif R. Soysal May 2019

Scintillation Event Localization In Novel Hemi-Ellipsoid Detector For Spect, Hanif R. Soysal

LSU Master's Theses

A high sensitivity Cardiac SPECT system using hemi-ellipsoid crystals with pinhole collimation was previously proposed by Dey et al. To investigate detector resolution for this design, the scintillation light spread on a monolithic hemi-ellipsoidal CsI crystal was simulated using Geant4 Monte Carlo. The expected distribution of scintillation light on the outer surface of the crystal from photoelectric absorption events was obtained from the simulations for selected points inside the crystal. Two sets of simulations were performed. For the first set, a look-up table (LUT) of 12 points was created and each point mapped to its expected light distribution—four points at …


Evaluation Of Ventilation Assistance For Improving Respiratory Reproducibility In Radiation Therapy, Cameron J. Sprowls Apr 2019

Evaluation Of Ventilation Assistance For Improving Respiratory Reproducibility In Radiation Therapy, Cameron J. Sprowls

LSU Master's Theses

Background: Respiratory motion affects all tumor sites in the thorax and abdomen. Variations of the respiratory pattern cause variations of the tumor motion which can result in differences between the planned and delivered dose distributions. Previous breathing guidance techniques have been investigated to improve respiratory reproducibility; however, ventilation assistance has not been investigated. We evaluated using bi-level positive airway pressure (BIPAP) ventilation assistance for improving respiratory reproducibility in patients with tumor sites impacted by respiratory motion.

Methods: Written informed consent was obtained for 10 patients currently undergoing radiation therapy treatment. Patients participated in sessions over their course of treatment, which …


Investigation Of Stereotactic Body Radiation Therapy Delivery Accuracy On An Elekta Linear Accelerator, Addie Barron Jul 2018

Investigation Of Stereotactic Body Radiation Therapy Delivery Accuracy On An Elekta Linear Accelerator, Addie Barron

LSU Master's Theses

Purpose: This work investigated the delivery accuracy of high-dose lung and spine stereotactic treatments delivered with the Elekta Infinity and Versa HD platforms. The accuracy of these platforms will be used for consideration in implementing a spine stereotactic radiosurgery (SSRS) program at Mary Bird Perkins Cancer Center.

Methods: A geometric phantom was used to perform Winston-Lutz type tests that assessed the relevant degrees of freedom (gantry, collimator, and couch) of the delivery system. A lung stereotactic body radiation therapy (SBRT) and spine SRS treatment plan were generated for use in end-to-end testing. Delivery accuracy was tested using a novel diode …


Benefit Of Intensity Modulated Bolus Electron Conformal Therapy For Post Mastectomy Chest Wall Irradiation, John Doiron Jan 2018

Benefit Of Intensity Modulated Bolus Electron Conformal Therapy For Post Mastectomy Chest Wall Irradiation, John Doiron

LSU Master's Theses

Purpose: The delivery of post-mastectomy radiotherapy (PMRT) with bolus electron conformal therapy (BECT) for patients with left-sided breast cancer can reduce second cancer complication probability (SCCP) compared to modern rotational intensity modulated x-ray (IMXT) techniques such as volumetric modulated arc therapy (VMAT) or Tomotherapy. However, rotational IMXT yields superior levels of dose homogeneity compared to BECT. This study investigates the use of intensity modulated (IM) BECT (IM-BECT) to improve dose homogeneity in the chest wall (CW) region of the PMRT planning target volume (PTV) abutted to parallel opposed IMXT tangents for the remaining PTV for a clinically-representative set of patients, …