Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 3 of 3
Full-Text Articles in Medicine and Health Sciences
Stride Length-Speed Relationship During Body Weight Supported Running, Carmen Chona
Stride Length-Speed Relationship During Body Weight Supported Running, Carmen Chona
UNLV Theses, Dissertations, Professional Papers, and Capstones
The purpose of this study was to determine if body weight support influences the stride length-speed relationship. Additionally, the purpose was to determine if impact characteristics of running are influenced by body weight support and speed. Subjects (n=10; 6 female, 4 male) volunteered to participate in this study. All subjects were injury free and were comfortable running on a treadmill for 30 minutes. Subjects ran on a lower body positive (LBPP, Alter-G, G-Trainer) treadmill for 4 conditions of body weight (100, 40, 30 and 20% of body weight) and 4 running speeds (100, 110, 120 and 130% of the preferred …
An Evaluation Of Kinematic Variables During Stance Phase Of A Training Endurance Run, Joshua Paul Bailey
An Evaluation Of Kinematic Variables During Stance Phase Of A Training Endurance Run, Joshua Paul Bailey
UNLV Theses, Dissertations, Professional Papers, and Capstones
The purpose of the study was to evaluate kinematics of the lower extremity during the stance phase of an endurance training run. Fifteen participants (8 male, 7 female; 30.5 ± 8.4 years; 71.8 ± 11 kg; 1.73 ± 0.07 m) reported that they were currently signed up for, or planned on signing up for, an endurance race within the next six months of participation in the study (9 half marathon, 3 marathon, 1 triathlon, 2 21k trail run). All had a weekly running mileage greater than 20 miles (23.8 ±4.6 miles). Participants were required to complete the 15–kilometer training run …
Biomechanical Analysis Of Gait Kinetics Resulting From Use Of A Vacuum Socket On A Transtibial Prosthesis, Maria De Lourdes Ramos Gonzalez
Biomechanical Analysis Of Gait Kinetics Resulting From Use Of A Vacuum Socket On A Transtibial Prosthesis, Maria De Lourdes Ramos Gonzalez
Honors College Theses
The technology and design of lower limb prosthetics have evolved greatly since their introduction. The current study proposed to compare the effects of a conventional pin socket attachment and a vacuum socket attachment for a transtibial amputee. Whereas traditional measurements of gait utilize force plates and camera systems, this study made use of a small tri-axial load cell located at the base of the socket to measure the forces and moments exerted during a regular gait cycle. The hypothesis tested stated that a vacuum pump socket attachment, when compared to a non-vacuum (pin) socket, will have a significant effect on …