Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Medicine and Health Sciences

White Matter Hyperintensity Associations With Cerebral Blood Flow In Elderly Subjects Stratified By Cerebrovascular Risk, Ahmed A. Bahrani, David K. Powell, Guoqiang Yu, Eleanor S. Johnson, Gregory A. Jicha, Charles D. Smith Apr 2017

White Matter Hyperintensity Associations With Cerebral Blood Flow In Elderly Subjects Stratified By Cerebrovascular Risk, Ahmed A. Bahrani, David K. Powell, Guoqiang Yu, Eleanor S. Johnson, Gregory A. Jicha, Charles D. Smith

Biomedical Engineering Faculty Publications

Objective: This study aims to add clarity to the relationship between deep and periventricular brain white matter hyperintensities (WMHs), cerebral blood flow (CBF), and cerebrovascular risk in older persons. Methods: Deep white matter hyperintensity (dWMH) and periventricular white matter hyperintensity (pWMH) and regional gray matter (GM) and white matter (WM) blood flow from arterial spin labeling were quantified from magnetic resonance imaging scans of 26 cognitively normal elderly subjects stratified by cerebrovascular disease (CVD) risk. Fluidattenuated inversion recovery images were acquired using a high-resolution 3-dimensional (3-D) sequence that reduced partial volume effects seen with slicebased techniques. Results: dWMHs but not …


Design Of Radio-Frequency Arrays For Ultra-High Field Mri, Ian R O Connell Jan 2017

Design Of Radio-Frequency Arrays For Ultra-High Field Mri, Ian R O Connell

Electronic Thesis and Dissertation Repository

Magnetic Resonance Imaging (MRI) is an indispensable, non-invasive diagnostic tool for the assessment of disease and function. As an investigational device, MRI has found routine use in both basic science research and medicine for both human and non-human subjects.

Due to the potential increase in spatial resolution, signal-to-noise ratio (SNR), and the ability to exploit novel tissue contrasts, the main magnetic field strength of human MRI scanners has steadily increased since inception. Beginning in the early 1980’s, 0.15 T human MRI scanners have steadily risen in main magnetic field strength with ultra-high field (UHF) 8 T MRI systems deemed to …


Validation, Optimization, And Image Processing Of Spiral Cine Dense Magnetic Resonance Imaging For The Quantification Of Left And Right Ventricular Mechanics, Gregory J. Wehner Jan 2017

Validation, Optimization, And Image Processing Of Spiral Cine Dense Magnetic Resonance Imaging For The Quantification Of Left And Right Ventricular Mechanics, Gregory J. Wehner

Theses and Dissertations--Biomedical Engineering

Recent evidence suggests that cardiac mechanics (e.g. cardiac strains) are better measures of heart function compared to common clinical metrics like ejection fraction. However, commonly-used parameters of cardiac mechanics remain limited to just a few measurements averaged over the whole left ventricle. We hypothesized that recent advances in cardiac magnetic resonance imaging (MRI) could be extended to provide measures of cardiac mechanics throughout the left and right ventricles (LV and RV, respectively).

Displacement Encoding with Stimulated Echoes (DENSE) is a cardiac MRI technique that has been validated for measuring LV mechanics at a magnetic field strength of 1.5 T but …