Biomechanical Analysis Of Ligament Modelling Techniques And Femoral Component Malrotation Following Tka, Liam A. Montgomery Dec 2021

Biomechanical Analysis Of Ligament Modelling Techniques And Femoral Component Malrotation Following Tka, Liam A. Montgomery

Electronic Thesis and Dissertation Repository

Previous studies have demonstrated that satisfaction and revision rates following total knee arthroplasty (TKA) are lower than those of comparable surgeries such as total hip replacements. A leading cause for these revisions is joint instability which may be due to improper ligament balancing or poorly aligned surgical implants. One of the methods used to investigate biomechanical forces and kinematics is computational modelling of the post-operative TKA knee.

A unique knee model was used to investigate the biomechanical and kinematic effects of ligament model complexity, as well as the effects of simulating ligament wrapping versus ignoring ligament wrapping. We then used …


Effect Of Levodopa On Eeg Connectivity In Parkinson's Patients, Sepehr Torab Parhiz Dec 2021

Effect Of Levodopa On Eeg Connectivity In Parkinson's Patients, Sepehr Torab Parhiz

Electronic Thesis and Dissertation Repository

Levodopa is a dopamine replacement medication administered to patients with Parkinson’s disease (PD) to alleviate their motor symptoms. However, its long-term use can cause adverse side effects, including involuntary motor movements. We studied 16 PD patients before and after taking Levodopa based on resting-state electroencephalography (EEG) recordings to determine how Levodopa affects the functional connectivity of their brain networks. We used several metrics from graph theory, in particular the minimum spanning tree (MST) metric, and analyzed how they change after subjects take Levodopa. We observed significant changes in the lower alpha band toward a more path-like and less globally efficient …


4dct Analysis Of In-Vivo Carpal Kinematics During Fem, Manisha R. Mistry Sep 2021

4dct Analysis Of In-Vivo Carpal Kinematics During Fem, Manisha R. Mistry

Electronic Thesis and Dissertation Repository

A consensus, detailed understanding of carpal kinematics remains elusive. 4-dimensional CT (4DCT) is a validated modality capable of accurately studying in-vivokinematic motion. The objective of this work is to quantify normal, in-vivo kinematic motion of the carpus through a flexion-extension arc of motion using 4DCT. Ten healthy, un-injured volunteers underwent a 4DCT scanning protocol through a complete arc of flexion-extension motion. Kinematic changes in motion were quantified using helical axis motion data for each carpal bone. Helical axes were compared between bones and statistical analysis performed using repeated-measures ANOVA to identify difference in kinematic motion between bones (p<0.05). The carpus can be divided into four main kinematic blocks: the distal carpal block, the proximal carpal block and individual scaphoid and trapezial blocks. This work supports an additional segmentation of the trapezium from the distal carpal row, which suggests some modulation between the scaphoid and distal carpal row.


Frequency Dependent Diffusion Kurtosis Measurement In The Human Brain With Oscillating Gradients, Kevin B. Borsos Aug 2021

Frequency Dependent Diffusion Kurtosis Measurement In The Human Brain With Oscillating Gradients, Kevin B. Borsos

Electronic Thesis and Dissertation Repository

Oscillating gradient spin-echo (OGSE) is an implementation of diffusion MRI that enables shorter effective diffusion times than the conventional pulse gradient spin-echo (PGSE) by periodically modulating the diffusion gradient. Measurements of the diffusion kurtosis, which reflects the degree of restricted diffusion, have previously been prohibited with OGSE due to technical limitations of clinical gradient systems. This thesis presents a novel oscillating gradient waveform that enables the measurement of kurtosis using OGSE without requiring advanced gradient hardware. Decreases of kurtosis are observed in OGSE acquisitions of healthy human subjects relative to PGSE, demonstrating the dependence of the kurtosis on oscillation frequency. …


Catechol-Containing Copolymers As An Active Ingredient For Denture Adhesives, Vincent Ying Wun Kong Apr 2021

Catechol-Containing Copolymers As An Active Ingredient For Denture Adhesives, Vincent Ying Wun Kong

Electronic Thesis and Dissertation Repository

Moisture inside the mouth adds challenge to making denture adhesives formulations. Some formulations have zinc to enhance adhesion on wet skin despite knowing the health hazards. Inspired by mussel foot proteins’ catechol unit’s strong underwater adhesion, nine catechol-containing copolymers (P1A-P3C) were synthesized by free radical polymerization of 3,4-dimethoxystyrene (3,4- DMS) with different styrene derivatives followed by deprotection. P1A-P3C were used to make Fn(P)-C-PBS denture adhesive formulations which had suitable shear stresses around ≥ 5 kPa satisfying ISO 10873. In-situ NMR studies of free radical polymerization of 3,4 - DMS and styrene derivatives allowed computation of their reactivity ratios showing all …


In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly Jan 2021

In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly

Electronic Thesis and Dissertation Repository

Optimal management of the hip capsule during arthroscopic surgery has not been established. The impact of incisions made to the capsule during minimally invasive procedures on joint biomechanics, and whether repair provides any benefit, continue to be debated. The effectiveness of capsular repair to restore native kinematics may be insufficient. Therefore, a better understanding of joint behavior during various capsule conditions is needed. A new robotic system was used to analyze the effect of progressive capsulotomy incision and repairs on the behavior of a normal hip within range of motion (ROM) limits with respect to the intact joint. Complete repairs …