Chemical And Polymer Characterization Of The Potential Modes Of Degradation Of An Injectable Nucleus Pulposus Replacement Device, Antonio G. Abbondandolo
Chemical And Polymer Characterization Of The Potential Modes Of Degradation Of An Injectable Nucleus Pulposus Replacement Device, Antonio G. Abbondandolo
Theses and Dissertations
HYDRAFIL™ is a poly(vinyl alcohol)/poly(ethylene glycol)-based hydrogel nucleus pulposus replacement device that is injected in situ and has demonstrated efficacy in lowering the prevalence and pain associated with back. In this work, we developed a method to analyze HYDRAFIL™ polymer composition using (TGA) and characterized intermolecular bonding interactions within the hydrogel through (FTIR). To function as a permanent implant for nucleus pulposus replacement, HYDRAFIL™ must be stable when exposed to a multitude of degradation pathways, namely, thermal, chemical, and mechanical. We subjected HYDRAFIL™ to accelerated thermal and chemical degradation pathways and described compositional, physical and chemical property changes using a …