Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 10 of 10

Full-Text Articles in Medicine and Health Sciences

Managing Intracranial Hemorrhage In Patients With A Durable Continuous Flow Left Ventricular Assist Device, Godly Jack, Phil Barker, Ryan Searcy, Jason N. Katz Jul 2019

Managing Intracranial Hemorrhage In Patients With A Durable Continuous Flow Left Ventricular Assist Device, Godly Jack, Phil Barker, Ryan Searcy, Jason N. Katz

The VAD Journal

Background: While intracranial hemorrhage (ICH) is a known complication of left ventricular assist device (LVAD) support, and is associated with high morbidity and mortality, optimal care pathways have neither been elucidated nor reported. We describe management of LVAD patients following ICH, with a focus on anticoagulation, operative interventions, care team designation, complications, and outcomes.

Methods: We retrospectively reviewed all durable continuous-flow LVAD implantations at our academic medical center from January 2007 to July 2018. Patients who experienced ICH after LVAD were identified. We defined baseline and ICH characteristics, medical and surgical interventions, care teams, and outcomes including death, device thrombosis, …


Successful Extracorporeal Membrane Oxygenation In The Management Of Acute Respiratory Distress Syndrome And Cardiopulmonary Collapse Secondary To Amniotic Fluid Embolism, Sumon Roy, Nishit A. Biniwale, Venkata S. Pendela, Patricia Oates, Katrina Wojciechowski, Scott C. Feitell Mar 2019

Successful Extracorporeal Membrane Oxygenation In The Management Of Acute Respiratory Distress Syndrome And Cardiopulmonary Collapse Secondary To Amniotic Fluid Embolism, Sumon Roy, Nishit A. Biniwale, Venkata S. Pendela, Patricia Oates, Katrina Wojciechowski, Scott C. Feitell

The VAD Journal

Amniotic fluid embolism (AFE) is one of the most devastating complications of pregnancy that typically manifests as acute cardiopulmonary collapse during delivery or in the postpartum period. The potential role of extracorporeal membrane oxygenation (ECMO) as a management technique in severe cases of AFE remains largely unknown given the limited literature available. In this report, we present the first case, to our knowledge, of successful implementation of ECMO as a life-saving measure in a case of hemorrhagic shock due to postpartum bleeding complicated by severe AFE leading to acute respiratory distress syndrome (ARDS) ultimately requiring tracheostomy. Hemodynamic decompensation is often …


De-Airing Method Of An Axial Flow Left Ventricular Assist Device Influences Post-Operative Lactate Dehydrogenase Levels: A Possible Explanation For Some Episodes Of Pump Thrombosis, Daizo Tanaka, Saif Rizvi, Andrew Boyle, Md, John W..C. Entwistle Sep 2018

De-Airing Method Of An Axial Flow Left Ventricular Assist Device Influences Post-Operative Lactate Dehydrogenase Levels: A Possible Explanation For Some Episodes Of Pump Thrombosis, Daizo Tanaka, Saif Rizvi, Andrew Boyle, Md, John W..C. Entwistle

The VAD Journal

Background

Pump thrombosis (PT) is a relatively uncommon but serious complication of a left ventricular assist device (LVAD). We believe that de-airing of the HeartMate II (HMII) with the pump turned on and a clamp across the outflow graft may lead to early thrombus formation due to heat generation on the bearings.

Methods

Patients who underwent HMII implantation from November 2012 to February 2016 were retrospectively reviewed. Patients were separated into two groups depending on the timing of removing the clamp from the outflow graft. Patients in Group 1 underwent de-airing by turning on the pump with the vascular clamp …


Safety And Efficacy Of Routine Bridging Anticoagulation For Subtherapeutic Anticoagulation In Outpatients With A Left Ventricular Assist Device, David C. Shisler, Gaurang N. Vaidya, Lori Muncy, Rajakrishnan Vijayakrishnan, Mark S. Slaughter, Emma J. Birks, Dmitry Abramov Aug 2018

Safety And Efficacy Of Routine Bridging Anticoagulation For Subtherapeutic Anticoagulation In Outpatients With A Left Ventricular Assist Device, David C. Shisler, Gaurang N. Vaidya, Lori Muncy, Rajakrishnan Vijayakrishnan, Mark S. Slaughter, Emma J. Birks, Dmitry Abramov

The VAD Journal

Background

Anticoagulation with vitamin K antagonists is vital to prevent pump thrombosis in patients with left ventricular assist devices (LVADs). However, the safety and efficacy of bridging anticoagulation for the routine management of subtherapeutic international normalized ratio (INR) in stable outpatients remains poorly characterized.

Methods

In this retrospective study, a total of 60 LVAD outpatients had 110 episodes of subtherapeutic INR noted on routine testing. 34 of these episodes were managed with parenteral bridging anticoagulation and 76 were managed with only an adjusted dose of warfarin. The rates of bleeding and thromboembolic adverse events following these episodes of subtherapeutic INR …


Venoarterial Extracorporeal Membrane Oxygenation For Cardiogenic Shock: A Retrospective Analysis Based On The Etiology Of Shock, Andrew Burchett, Thomas Tribble, Richard Charnigo, Susan Smyth, Maya Guglin Mar 2017

Venoarterial Extracorporeal Membrane Oxygenation For Cardiogenic Shock: A Retrospective Analysis Based On The Etiology Of Shock, Andrew Burchett, Thomas Tribble, Richard Charnigo, Susan Smyth, Maya Guglin

The VAD Journal

Abstract:

Background: We performed a retrospective analysis to evaluate the efficacy of VA-ECMO support in cardiogenic shock based on various etiologies.

Methods: We retrospectively analyzed 99 patients supported with VA-ECMO from January 1, 2012 to January 1, 2015. Outcomes included survival to discontinuation of VA-ECMO support and survival to hospital discharge. The etiologies of cardiogenic shock included cardiac arrest (CPR), acute myocardial infarction (AMI), decompensated congestive heart failure (CHF), pulmonary embolism (PE), right ventricular failure (RVF) not secondary to an acute pulmonary embolism, and post-cardiotomy syndrome (PCS). The PCS group was used as a reference group; odds ratios were estimated …


Acute Appendicitis: A Potential Complication Of Continuous-Flow Left Ventricular Assist Device Support, Joshua S. Roark, Akinniran A. Abisogun, Jason N. Katz Aug 2016

Acute Appendicitis: A Potential Complication Of Continuous-Flow Left Ventricular Assist Device Support, Joshua S. Roark, Akinniran A. Abisogun, Jason N. Katz

The VAD Journal

Acute appendicitis, while common in younger patients, is an unusual cause for hospitalization among older adults. We report a case series of 3 individuals who had been previously implanted with a continuous-flow left ventricular assist device (CF-LVAD) for end-stage heart failure, and who subsequently developed acute appendicitis. Both axial-flow technology and nonpulsatile systemic blood flow have been implicated as potential causes for bleeding and thrombosis in contemporary LVAD populations(1-3). This case series represents the first report of acute appendicitis as an adverse event following LVAD implantation and represents a patient demographic that would historically be at very low-risk for this …


The Utility Of Remote Hemodynamic Monitoring Devices In Patients With A Ventricular Assist Device, Bennet George, Amanda Hart, Sarah Branam, Maya Guglin May 2016

The Utility Of Remote Hemodynamic Monitoring Devices In Patients With A Ventricular Assist Device, Bennet George, Amanda Hart, Sarah Branam, Maya Guglin

The VAD Journal

Remote intracardiac hemodynamic monitoring is a growing area of interest to help aid in the management of patients with chronic congestive heart failure. The utility of remote hemodynamic monitoring has not previously been investigated with a ventricular assist device population. We present two cases of patients with ventricular assist devices in which we employed remote hemodynamic monitoring data to aid in patient management.


Commentary On "Systemic Candidiasis And Cytomegalovirus Infection In The Setting Of Artificial Cardiac Device Deployment", Moises A. Huaman Aug 2015

Commentary On "Systemic Candidiasis And Cytomegalovirus Infection In The Setting Of Artificial Cardiac Device Deployment", Moises A. Huaman

The VAD Journal

No abstract provided.


Chronic Ldh Elevation After Left Ventricular Assist Device Implantation, Hesham R. Omar, Navin Rajagopalan, Maya Guglin Aug 2015

Chronic Ldh Elevation After Left Ventricular Assist Device Implantation, Hesham R. Omar, Navin Rajagopalan, Maya Guglin

The VAD Journal

A 61-year-old woman who underwent HeartMate II left ventricular assist device placement for non-ischemic cardiomyopathy developed elevated lactate dehydrogenase within two weeks after implantation. After eight months of observation and several hospital admissions during which there was no evidence of pump thrombosis, she presented with clinically manifest hemolysis. During pump exchange there was notable pannus formation on the inflow cannula of the left ventricular assist device. The pannus around the inflow likely existed for several months, limiting the flow and creating a low-grade hemolysis and this low flow state stimulated thrombus formation triggering gross hemolysis. Thoratec analysis of the pump …


Old Dog, New Tricks - Usefulness Of The Ecg In Monitoring Acute Rejection Post Cardiac Transplantation, Paul Anaya, Samy-Claude Elayi Feb 2015

Old Dog, New Tricks - Usefulness Of The Ecg In Monitoring Acute Rejection Post Cardiac Transplantation, Paul Anaya, Samy-Claude Elayi

The VAD Journal

Electrocardiographic abnormalities have been described in the setting of acute rejection following orthotopic cardiac transplantation. The following is a brief commentary related to an interesting case report by Goldraich et al. which was recently published in the VAD Journal.