Development And Testing Of A Low-Cost Condensation Detection System, Michael D. Montross, George A. Duncan, Richard S. Gates Jul 2006

Development And Testing Of A Low-Cost Condensation Detection System, Michael D. Montross, George A. Duncan, Richard S. Gates

Biosystems and Agricultural Engineering Faculty Publications

A condensation sensing and control system was designed to detect condensation using a commercially available leaf wetness sensor (LWS). The leaf wetness sensor was a variable resistance grid-type that responded to moisture on the surface. A circuit was developed to compare the LWS voltage output to a user specified reference voltage, and operate a relay for possible switching of a humidity control device (for example a fan and/or heater). The condensation detection system operation was validated in an environmental chamber in the laboratory using a heat exchanger and water bath. Condensate was immediately detected when the plate was cooled below …


Dynamic Modeling Of Microclimate And Environmental Control Strategies In A Greenhouse Coupled With A Heat Pump System, Ilhami Yildiz, D. P. Stombaugh Jan 2006

Dynamic Modeling Of Microclimate And Environmental Control Strategies In A Greenhouse Coupled With A Heat Pump System, Ilhami Yildiz, D. P. Stombaugh

BioResource and Agricultural Engineering

The purpose of this study was to develop and validate a dynamic simulation model to be employed in accurate prediction of microclimate in a greenhouse as a function of dynamic environmental factors. The model has options to evaluate the effects of location, time of the year, orientation, single and double polyethylene glazings, conventional and heat pump heating and cooling systems, open and confined greenhouse systems, CO2 enrichment, variable shading, and the use of night curtains. Conventional gas furnace and evaporative cooling, respectively, provided heating and cooling in the conventional system. In the heat pump systems, gas-fired heat pump units …


Simulated Performances Of A Heat Pump System For Energy And Water Conservation In Open And Confined Greenhouse Systems, Ilhami Yildiz, D. P. Stombaugh Jan 2006

Simulated Performances Of A Heat Pump System For Energy And Water Conservation In Open And Confined Greenhouse Systems, Ilhami Yildiz, D. P. Stombaugh

BioResource and Agricultural Engineering

The purpose of this study was to determine and compare the performances of conventional and heat pump systems for energy and water conservation in open and confined greenhouse systems. Conventional gas furnaces and evaporative cooling, respectively, provided heating and cooling in the conventional system. In the heat pump systems, gas-fired heat pump units provided both heating and cooling. The greenhouse with heat pump units also had an option to be operated as a completely confined system, using one of the heat pump units as a dehumidifier. Average energy consumption in winter was 56.9, 23.5, and 11.3 MJ/day.m² in the conventional, …


Air Exchange Rate In A Horse Trailer During Road Transport, Joseph L. Purswell, Richard S. Gates, Laurie M. Lawrence, Jamey D. Jacob, Timothy S. Stombaugh, Robert J. Coleman Jan 2006

Air Exchange Rate In A Horse Trailer During Road Transport, Joseph L. Purswell, Richard S. Gates, Laurie M. Lawrence, Jamey D. Jacob, Timothy S. Stombaugh, Robert J. Coleman

Biosystems and Agricultural Engineering Faculty Publications

Horses traveling by road commonly experience heat stress conditions and poor air quality, which may be caused by insufficient ventilation; however, there are few estimates of air exchange in a horse trailer during transport. Air exchange rate was measured at ten locations within a four-horse trailer (internal volume 18.5 m3) using tracer gas decay measurement to assess the adequacy of ventilation. Three vehicle speeds (13, 48, and 97 km h-1) and three window configurations (all windows and roof vents closed, all windows open, all windows open and roof vents open forward) were tested with and without …