Open Access. Powered by Scholars. Published by Universities.®

Life Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Utah State University

1985

Scanning Electron Microscopy

Colloidal Gold

Articles 1 - 2 of 2

Full-Text Articles in Life Sciences

Observation Of Colloidal Gold Labelled Platelet Surface Receptors And The Underlying Cytoskeleton Using High Voltage Electron Microscopy And Scanning Electron Microscopy, R. M. Albrecht, J. A. Oliver, J. C. Loftus Jan 1985

Observation Of Colloidal Gold Labelled Platelet Surface Receptors And The Underlying Cytoskeleton Using High Voltage Electron Microscopy And Scanning Electron Microscopy, R. M. Albrecht, J. A. Oliver, J. C. Loftus

Scanning Electron Microscopy

Fibrinogen conjugated to colloidal gold or colloidal gold-monoclonal anti-glycoprotein IIb/IIIa (fibrinogen receptor) was used to label the receptor on platelets. Whole mount preparations were examined by stereo pair high voltage electron microscopy and then by scanning electron microscopy to determine the feasibility of this approach in detecting the number of receptors and their location relative to the cytoskeletal and surface structure. Both the ligand-gold and antibody-gold labels were effective. The relative numbers of receptors could be seen and their relationship to cytoskeletal structure could be determined. Marked differences in receptor number and distribution were observed when platelets in different stages …


Colloidal Gold Particles Detected On Highly Structured Surfaces Of Large Samples By Backscattered Electrons In The Scanning Electron Microscope, D. Studer, R. Hermann Jan 1985

Colloidal Gold Particles Detected On Highly Structured Surfaces Of Large Samples By Backscattered Electrons In The Scanning Electron Microscope, D. Studer, R. Hermann

Scanning Electron Microscopy

Colloidal gold labelled surface antigens on large, highly structured samples were unambiguously visualized at high magnification with backscattered electrons at 25 kV in a field emission scanning electron microscope (SEM). Secondary electron (SE) and backscattered electron (BSE) images of large and highly structured specimens are frequently disturbed by charging effects. By optimizing the thickness of the conducting carbon layer and the intensity of the incident electron beam, this problem can be overcome. The midgut of the lepidopteran larvae of Spodoptera litoralis was used as specimen. The activated 𝛿-endotoxin of Bacillus thuringiensis coupled to colloidal gold binds to the microvilli exposed …