Rate Response Assessment From Various Granular Vrt Applicators, John P. Fulton, Scott A. Shearer, Stephen F. Higgins, Matthew J. Darr, Timothy S. Stombaugh Nov 2005

Rate Response Assessment From Various Granular Vrt Applicators, John P. Fulton, Scott A. Shearer, Stephen F. Higgins, Matthew J. Darr, Timothy S. Stombaugh

Biosystems and Agricultural Engineering Faculty Publications

Variable-rate technology (VRT) adds complexity to application equipment, thereby confounding the assessment of applicator performance. The intent of this investigation was to assess the rate response of various VRT granular applicators: two spinner spreaders (A and B), and two pneumatic applicators (C and D). Variable-rate (VR) tests were conducted to quantify the rate response characteristics (delay and transition times) for the applicators. A sigmoidal function was used to model the rate response for five of the six tests. Applicator A exhibited a linear response during decreasing rate changes. Results indicated that only applicator B demonstrated consistent delay and transition times, …