Articles 1 - 14 of 14

Full-Text Articles in Other Engineering

Design Fire Robert E. Kennedy Library, California Polytechnic State, San Luis Obispo, Jennifer Ocampo Jun 2023

Design Fire Robert E. Kennedy Library, California Polytechnic State, San Luis Obispo, Jennifer Ocampo

Fire Protection Engineering: Culminating Experience Project Reports

This report evaluates the fire protection system of the Kennedy Building using a prescriptive approach and a performance-based design. The prescriptive approach evaluates code compliance of the structural design, fire suppression system, alarm and detection and smoke control. The performance-based design evaluates egress and life safety protection and three design fires that could potentially compromise the goals and objectives of the design.

The Kennedy Building is on the Campus of Cal Poly, San Luis Obispo and serves as the primary library of the university. This building has five stories of mixed occupancies. It is partially sprinklered, has limited automatic detection …


Fire Protection Engineering For Building A, Ai Choong Loh Jun 2023

Fire Protection Engineering For Building A, Ai Choong Loh

Fire Protection Engineering: Culminating Experience Project Reports

Building A is a 9-storey mixed used development in Singapore to be completed in 2028. Fire safety provisions of Building A shall be in accordance with Singapore Fire Code 2018.

The report has analyzed the fire safety provisions in the area of structural fire protection provision, means of escape provision, automatic water suppression system provision, automatic fire detection and alarm system provision, engineering smoke control system provision, flammability assessment as well as performance based assessment.

Generally, building A complied to the prescriptive requirements of automatic water suppression system provision, automatic fire detection and alarm system, structural fire provision and means …


Office Building In Moffett Park District, Cody Williams Jun 2023

Office Building In Moffett Park District, Cody Williams

Fire Protection Engineering: Culminating Experience Project Reports

The objective of this review is to analyze and evaluate the fire safety of a 5-story office building located in the Moffett Park District in Sunnyvale, California. The building is constructed largely of mass timber and classified as a Type IIIA building used primarily as office space. The first section of the report focuses on the building’s defining characteristics and use cases. The second portion of the report presents a comprehensive review of egress design, fire alarm systems, fire suppression systems, structural design, implementation of mass timber elements, and flammability requirements. The results of the analysis show that the building …


Fire Protection Analysis Of A K-12 Classroom Building, Raymond Yip Jun 2023

Fire Protection Analysis Of A K-12 Classroom Building, Raymond Yip

Fire Protection Engineering: Culminating Experience Project Reports

The report evaluates the fire protection features of a K-12 classroom building (Bldg. B) in San Bernardino County, California. Bldg. B is a two-story Type V-A light timber frame construction. At the time of this report’s composition, Bldg. B is undergoing modernization construction. The fire protection analysis of this building consists of prescriptive and performance portions.

The prescriptive analysis verifies the compliance of building egress, passive, and active protection features with the 2019 edition of California Codes of Regulations Title 24 (Title 24) and Title 24-adopted National Fire Protection Association (NFPA) standards. The analysis comprises of four sections: egress, structural …


Food Processing And Campus Market (Building 24), Ian De Vries Jun 2023

Food Processing And Campus Market (Building 24), Ian De Vries

Fire Protection Engineering: Culminating Experience Project Reports

This report provides a prescriptive and performance-based analysis of the Food Processing Building located on Cal Poly’s campus in San Luis Obispo, California. Food science and nutrition classes take place at the facility where faculty and students manufacture food products such as chocolates, jams, and barbecue sauces. The finished products are offered for sale in the building’s mercantile area, known as the Campus Market, in addition to other retail locations around the city. The Food Processing Building is considered mixed use with portions of the building classified as moderate-hazard factory (F-1), moderate-hazard storage (S-1), business (B), mercantile (M), and assembly …


Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger Jun 2023

Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger

Fire Protection Engineering: Culminating Experience Project Reports

Enclosed in this report is a comprehensive analysis of the fire protection and life safety components of the Illinois Department of Transportation (IDOT) District Six Headquarters building. The original building was constructed in 1972 and renovation operations were recently completed in 2022. The building is four stories in height with an aggregate floor area of approximately 69,300 square feet. The building functions as an office space for IDOT staff, therefore the majority of floor space is used as open office and private office space. The business spaces are supported by assembly spaces such as conference and break rooms on each …


University Of Washington Bill & Melinda Gates Center For Computer Science & Engineering, Devin Ide Jun 2023

University Of Washington Bill & Melinda Gates Center For Computer Science & Engineering, Devin Ide

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze and evaluate the prescriptive and performance-based criteria used to design the fire protection systems installed in the Gates Center for Computer Science and Engineering at the University of Washington, Seattle Campus. The Gates Center is a five-story building housing business and assembly spaces such as classrooms, workrooms, offices, a lecture hall, event center, and a café. The main architectural feature is a central atrium, which connects the ground, first, second, and third floors of the building.

Aspects of the prescriptive-based fire protection design include egress, automatic sprinkler systems, detection and notification devices, …


Fire And Life Safety Evaluation Of An Assisted Living And Memory Care Center, Sarah Chandonait Jun 2023

Fire And Life Safety Evaluation Of An Assisted Living And Memory Care Center, Sarah Chandonait

Fire Protection Engineering: Culminating Experience Project Reports

This culminating project has been submitted as part of the graduate program in Fire Protection Engineering at Cal Poly. It documents an Assisted Living and Memory Care Center’s compliance with applicable fire safety prescriptions contained in the 2019 California Building and Fire Codes (CBC and CFC). Performance-based methods incorporating deterministic design fires were then used to verify that the final building design and operating procedures met the life safety needs of its unique occupants.

The building under analysis was a 45,000 sq. ft, two-story, 58-bed residential care facility for the elderly. Occupants were all 60 years or older without acute …


Analysis Of Scramento State University Union, Zachary Schuler Jun 2023

Analysis Of Scramento State University Union, Zachary Schuler

Fire Protection Engineering: Culminating Experience Project Reports

Sacramento State Union is a centrally located building with a large occupant load during the school year. This building is a 239,000-square-foot three-story structure built originally back in 1975. This original building was constructed using waffle slab construction. Additions in 1996 and 2016 were built using steel beam and girder construction to meet the total square footage we have today. This mixed-use occupancy is not only a congregation point, but many events are held in this building as well.

In this analysis of the building, fire life safety systems are reviewed and determined if they not only meet the minimum …


Building San Francisco, Ca, Kevin Nguyen Jun 2023

Building San Francisco, Ca, Kevin Nguyen

Fire Protection Engineering: Culminating Experience Project Reports

The objective of this report is to conduct a thorough analysis and evaluation of the existing fire life safety and fire protection systems in place at the Building located in San Francisco, California. The building is classified as a Type II-A building and serves predominantly as office space. The building is six stories tall with a total gross area of approximately 97,170 SF.

The initial portion of this report concentrates on a thorough prescriptive-based analysis, which provides an evaluation of the egress design, fire alarm system, communication systems, fire suppression system, structural and construction design, smoke control, and flammability requirements. …


Fire Protection And Life Safety Analysis Of The 2704-Hv Hanford Building, Guillermo Rodriguez Jun 2023

Fire Protection And Life Safety Analysis Of The 2704-Hv Hanford Building, Guillermo Rodriguez

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes multiple aspects of fire protection and life safety design for the 2704-HV Building located at the Hanford Nuclear Reservation Site in Washington State. The analysis contained within focuses on both prescriptive and performance-based designs for the fire systems within the structure. The 2704-HV building is a two-story office building containing approximately 90 individual full-office spaces on each floor along with approximately 60 individual cubicle office spaces on each floor. There are various other types of gathering spaces within the 2704-HV layout including: conference rooms, showers, kitchen and dining areas, training rooms, and lobbies.

The 2704-HV building was …


A Fire Protection And Life Safety Analysis Of An Oupatient Healthcare System Building, Conrad Chandler Jun 2023

A Fire Protection And Life Safety Analysis Of An Oupatient Healthcare System Building, Conrad Chandler

Fire Protection Engineering: Culminating Experience Project Reports

The subject building of the report is an outpatient healthcare system building that is a two stories in height and 184,670 SF building. This building offers primary, specialty, and mental health outpatient care to patients throughout its state of location.

The facility is a mixed occupancy building with business as the primary occupancy, a surgery suite that classifies as an ambulatory health care occupancy, and assembly uses in the conference rooms, kitchen, and canteen. The Authority Having Jurisdiction (AHJ) has adopted the National Fire Codes (NFC) published by the National Fire Protection Association (NFPA), and throughout this report, the life …


The Acme Building Fire Hazards Analysis, Russ Livesay Jun 2023

The Acme Building Fire Hazards Analysis, Russ Livesay

Fire Protection Engineering: Culminating Experience Project Reports

This Fire Hazards Analysis (FHA) was written using modern fire protection engineering principles to characterize the Applied Chemistry Management and Enrichment (ACME) Building at the Pacific Northwest National Research Area (PNNRA) using both a prescriptive-based and performance-based analysis to ensure the building and occupants can be safe in fire conditions. Recommendations are made as part of this analysis to improve the survivability of this structure if a fire were to occur.

This building was found to be compliant with the prescriptive code requirements from the 2018 International Building Code except for a few minor issues that are currently being repaired. …


Fire Life Safety Design Of Technology Office, Jared Ellis Mar 2023

Fire Life Safety Design Of Technology Office, Jared Ellis

Fire Protection Engineering: Culminating Experience Project Reports

The subject building is an approximately 180,000 SF technology office; the location and some details are omitted for privacy of the project and client. It is a 3-story heavy timber frame (Type IIIA) over 1 level of concrete basement stepped into a hillside.

The building is compliant with the prescriptive building code for egress, fire alarm, and fire sprinkler systems. A NFPA 72 compliant fire detection, notification and communication system is provided. The building is fully sprinklered with a system that is hydraulically designed per NFPA 13, 2016 Section 11.2.3 Water Demand Requirements – Hydraulic Calculation Methods. Water supply is …