Open Access. Powered by Scholars. Published by Universities.®

Other Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

California Polytechnic State University, San Luis Obispo

Performance Based Design

Articles 1 - 30 of 87

Full-Text Articles in Other Engineering

Office Building In Moffett Park District, Cody Williams Jun 2023

Office Building In Moffett Park District, Cody Williams

Fire Protection Engineering: Culminating Experience Project Reports

The objective of this review is to analyze and evaluate the fire safety of a 5-story office building located in the Moffett Park District in Sunnyvale, California. The building is constructed largely of mass timber and classified as a Type IIIA building used primarily as office space. The first section of the report focuses on the building’s defining characteristics and use cases. The second portion of the report presents a comprehensive review of egress design, fire alarm systems, fire suppression systems, structural design, implementation of mass timber elements, and flammability requirements. The results of the analysis show that the building …


Fire Protection Analysis Of A K-12 Classroom Building, Raymond Yip Jun 2023

Fire Protection Analysis Of A K-12 Classroom Building, Raymond Yip

Fire Protection Engineering: Culminating Experience Project Reports

The report evaluates the fire protection features of a K-12 classroom building (Bldg. B) in San Bernardino County, California. Bldg. B is a two-story Type V-A light timber frame construction. At the time of this report’s composition, Bldg. B is undergoing modernization construction. The fire protection analysis of this building consists of prescriptive and performance portions.

The prescriptive analysis verifies the compliance of building egress, passive, and active protection features with the 2019 edition of California Codes of Regulations Title 24 (Title 24) and Title 24-adopted National Fire Protection Association (NFPA) standards. The analysis comprises of four sections: egress, structural …


Food Processing And Campus Market (Building 24), Ian De Vries Jun 2023

Food Processing And Campus Market (Building 24), Ian De Vries

Fire Protection Engineering: Culminating Experience Project Reports

This report provides a prescriptive and performance-based analysis of the Food Processing Building located on Cal Poly’s campus in San Luis Obispo, California. Food science and nutrition classes take place at the facility where faculty and students manufacture food products such as chocolates, jams, and barbecue sauces. The finished products are offered for sale in the building’s mercantile area, known as the Campus Market, in addition to other retail locations around the city. The Food Processing Building is considered mixed use with portions of the building classified as moderate-hazard factory (F-1), moderate-hazard storage (S-1), business (B), mercantile (M), and assembly …


University Of Washington Bill & Melinda Gates Center For Computer Science & Engineering, Devin Ide Jun 2023

University Of Washington Bill & Melinda Gates Center For Computer Science & Engineering, Devin Ide

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze and evaluate the prescriptive and performance-based criteria used to design the fire protection systems installed in the Gates Center for Computer Science and Engineering at the University of Washington, Seattle Campus. The Gates Center is a five-story building housing business and assembly spaces such as classrooms, workrooms, offices, a lecture hall, event center, and a café. The main architectural feature is a central atrium, which connects the ground, first, second, and third floors of the building.

Aspects of the prescriptive-based fire protection design include egress, automatic sprinkler systems, detection and notification devices, …


Grange Insurance Audubon Center-Fire Protection Life Safety Report, Gabriel Levy Jun 2022

Grange Insurance Audubon Center-Fire Protection Life Safety Report, Gabriel Levy

Fire Protection Engineering: Culminating Experience Project Reports

This technical approach narrative presents the intent and methodology of the Fire Protection and Life Safety systems for the Grange Insurance Audubon Center located at 505 W Whittier St. Columbus OH 43215. The primary goal of the structure is to provide life and property protection in a fire scenario while taking into account the costs of implementing the criterion and risks associated with the facility. This will be achieved through the appropriate application of requirements listed in the 2015 International Building Code (IBC) and the International Fire Code (IFC) as adopted by the City of Columbus, Ohio, and any reference …


Warren Baker Center For Science And Mathematics- Fire Protection And Life Safety Analysis, Logan Honeycutt Jun 2022

Warren Baker Center For Science And Mathematics- Fire Protection And Life Safety Analysis, Logan Honeycutt

Fire Protection Engineering: Culminating Experience Project Reports

This report covers an analysis of the fire protection features within the Warren Baker Center for Science and Mathematics Building. This document first discusses the prescriptive requirements for the building as determined by applicable code. The items to be discussed, as they relate to prescriptive requirements, include the means of egress and relatable components, fire resistive construction, fire alarm system, fire sprinkler system, and smoke control system. All components were analyzed and compared to each applicable code to assess whether these specific fire protection systems were designed correctly.

In addition to an analysis of the prescriptive measures in this facility, …


Mount Sac Gym & Aquatics Center: Fire & Life Safety Report, Alex Hoeft Jun 2022

Mount Sac Gym & Aquatics Center: Fire & Life Safety Report, Alex Hoeft

Fire Protection Engineering: Culminating Experience Project Reports

This report has been prepared to review and analyze the Fire and Life Safety status of the proposed Gym & Aquatics building at Mt. San Antonio College. This was done using two methods: prescriptive and performance based. The prescriptive section examines the explicitly code-mandated requirements for the building and the performance-based section examines implicit requirements for the building based on the goals presented in the Life Safety Code, NFPA 101.

The subject building is a 147,000 square foot, two-story, steel-framed athletics complex occupied primarily for assembly and business uses. The structure has an indoor and outdoor component with two gymnasiums …


Fire Safety Management Plan For South Texas Project Turbine Generator Building, Brett Long Jun 2022

Fire Safety Management Plan For South Texas Project Turbine Generator Building, Brett Long

Fire Protection Engineering: Culminating Experience Project Reports

This report includes a fire protection and life safety analysis of the South Texas Project Turbine Generator Building (TGB). This analysis was done to fulfill the requirement for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University. The Turbine Generator Building consists of three elevations and is Type II-B construction. The TGB’s primary use is a special-purpose industrial building housing the turbine generator, main feed pumps, condensate pumps, condenser, feed water re-heaters, secondary cold chemistry lab, Balance-of-Plant (BOP) diesel, batteries, and switchgear, 13.8 kVA switchgear, and various other systems and components. This analysis consists of …


Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal Jun 2022

Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal

Fire Protection Engineering: Culminating Experience Project Reports

This report contains an analysis of the life safety and fire protection features of a four-story apartment building in Maple Grove, Minnesota. The report is a part of the final project intended to meet the requirements for the Culminating Experience of the California Polytechnic Master of Science Fire Protection Engineering Program.

The apartment building chosen for the analysis is a mixed-use four-story wood-framed structure. The first floor of this structure includes office space for building management, a meeting space, and various electrical and mechanical spaces as well as apartments. There are exit stairways on each end of the structure extending …


Jack E Brown Chemical Engineering Building At Texas A&M University, Daniel Higdon Jun 2022

Jack E Brown Chemical Engineering Building At Texas A&M University, Daniel Higdon

Fire Protection Engineering: Culminating Experience Project Reports

The Jack E Brown Chemical Engineering building at Texas A&M is located in College Station, TX. While this building is dedicated to chemical engineering, it serves many different departments as they use the lecture halls on the first floor. It was built and opened in 2004 and has 206,500 square feet with 7 stories. The building consists of multiple labs as well as study hall rooms, computer labs, offices, and the normal MEP/storage rooms. Jack E Brown building is one of the foremost buildings of the Texas A&M engineering quadrant and is further proof that Texas A&M desires to keep …


Fire Protection And Life Safety Analysis Of Christopher Cohan Center, Kristen Dentici Jun 2022

Fire Protection And Life Safety Analysis Of Christopher Cohan Center, Kristen Dentici

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes the fire protection and life safety systems of the Christopher Cohan Center. The building was assessed from both a prescriptive and performance-based approach.

The prescriptive design analyzed the code requirements for the building based on the 2018 IBC, with some consideration for the codes in place at the time of construction. The prescriptive analysis main focus was on egress systems, fire alarm and detection, fire suppression, and structural fire protection. The egress analysis found that the exits and exit configuration were sufficient for the occupant loads that were calculated for the building. The fire alarm and detection …


La Universal, Jose Emilio Salgado Florencia Jun 2022

La Universal, Jose Emilio Salgado Florencia

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this project was to analyze and compare the existing fire protection systems in “LA UNIVERSAL” building to current applicable codes and standards. Both prescriptive based analysis and performance-based analyses were performed.

The prescriptive based analyses included analyzing the structural fire protection, fire suppression, fire alarm, and egress systems. There are many fire protection features that do not meet the requirements established by the NFPA standards. The fire alarm panel does not provide enough address for the required number of devices required in the building. Emergency lights do not provide the minimum illumination established in NFPA 101. The …


Two-Storey Office Building, Colin Mallett Jun 2022

Two-Storey Office Building, Colin Mallett

Fire Protection Engineering: Culminating Experience Project Reports

This FPE 596 culminating project report was developed to meet the requirements for completion of the Fire Protection Master’s Program at Cal Poly. The report is intended to provide a detailed understanding of fire and building code requirements as well as describe both prescriptive and performance based approaches to human behavior in fire scenarios, building evacuation strategies, egress design and tenability analysis. An overall determination will be made to evaluate if the building provides the expected levels of safety for building occupants from fire.

The office building #211 was designed and constructed to be compliant with the International Building Code …


Construction Innovation Center At California Polytechnic State University, James Hunter Gildart Jun 2021

Construction Innovation Center At California Polytechnic State University, James Hunter Gildart

Fire Protection Engineering: Culminating Experience Project Reports

The building of interest for this project is the Construction Innovation Center (CIC) at California Polytechnic State University, San Luis Obispo. The CIC consists of 3 structures (buildings A, B, and C) equipped throughout with a wet pipe automatic sprinkler system and a fire alarm system with smoke detection. This report reviews the prescriptive and performance-based requirements along with providing a fire safety management plan. The prescriptive based portion of this report covers egress, fire alarm, automatic fire sprinklers, flammability, and structural fire protection requirements. Upon completion of the prescriptive code analysis comparing the CIC to the 2015 International Building …


College Sports Center Fire Protection Analysis, Elijah Kimmig Jun 2021

College Sports Center Fire Protection Analysis, Elijah Kimmig

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this project was to analyze and compare the existing fire protection systems in the college sports center to current applicable codes and standards. Both prescriptive based analysis and performance based analyses were performed.

The prescriptive based analyses included analyzing the structural fire protection, fire suppression, fire alarm, and egress systems. Overall, the majority of the fire protection systems appeared to meet the requirements of the current codes but there are a few items that were found that appear to not meet current code. These items are listed below along with recommendations to mitigate: (1) Placement of certain …


California Polytechnic State University – San Luis Obispo Building 180: Baker, Kelly Kessloff Jun 2021

California Polytechnic State University – San Luis Obispo Building 180: Baker, Kelly Kessloff

Fire Protection Engineering: Culminating Experience Project Reports

This project was performed as part of the requirements for completion of the Fire Protection Engineering Master’s Program at Cal Poly. This project covers a full prescriptive and performance based analysis on the Warren J. Baker Center for Science and Mathematics. This building was constructed on Cal Poly’s campus in 2013 and serves occupancies such as classrooms, laboratories, and office space for students and professors.

The prescriptive based analysis of this report will analyze the applicable building codes and determine if this building is compliant. Relevant codes include the 2016 California Building and the 2016 California Fire Code. In addition …


B-91 Fire Protection Analysis, Evan Phillips Jun 2021

B-91 Fire Protection Analysis, Evan Phillips

Fire Protection Engineering: Culminating Experience Project Reports

B-91 is a multiuse building on a Department of Defense installation rented out to a defense contractor consisting of laboratory, office, storage, and utility spaces. To determine the adequacy of the building’s fire protection systems as determined by the state-adopted 2015 International Building Code, a prescriptive analysis was performed with specific areas of focus on the building construction and occupancy, emergency egress capacity, fire suppression systems, and fire alarm systems. The building is compliant with code requirements in its construction and the fire alarm systems are adequately designed to provide notice, but the egress from the building’s main conference room …


Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag Jun 2021

Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag

Fire Protection Engineering: Culminating Experience Project Reports

The Canyon Vista Dining project is a renovation of an existing two-story dining facility located in the Warren College area of the University of California San Diego campus for the owners, Housing, Dining and Hospitality. The renovation scope of work comprised a new dining experience with a better diversity of food options and indoor and outdoor seating, which upgraded the first floor, second floor, and mechanical penthouse. In the course of the design and construction, the prescriptive, performance, wildfire, and due diligence design results were utilized during discussions with design team and building permit approval. The project construction was completed …


Fire Protection Analysis Of Johnson Controls Office Building, Derek Driscoll Jun 2021

Fire Protection Analysis Of Johnson Controls Office Building, Derek Driscoll

Fire Protection Engineering: Culminating Experience Project Reports

This project report contains a fire and life safety analysis of the Johnson Controls Office Building. The building is located in Los Angeles, California. The building is a mixed use occupancy with office spaces, meeting rooms, training rooms, and a warehouse for storing fire sprinkler and fire alarm materials. The building is one level with a mezzanine. It is attached to another building and separated by fire barrier so that they are considered separate buildings. This report contains a prescriptive analysis and a performance-based design analysis of the building.

The prescriptive code requirements were determined based on the 2019 edition …


Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton Jun 2020

Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton

Fire Protection Engineering: Culminating Experience Project Reports

The following report contains an analysis of the life safety and fire protection features of a Chicago Hotel. The report is intended to meet the requirements for the Culminating Experience of the Cal Poly Master of Science Fire Protection Engineering Program.

The Chicago Hotel building chosen for the analysis is a mixed-use 7-story hotel. On the 1st, 2nd, and 7th floors of the building are spaces for mercantile and restaurant tenants as well as other spaces necessary for the operation of the building such as back of house space for the hotel, storage, employee locker rooms, hotel and retail lobbies, …


Building B: Fire And Life Safety Analysis, Joseph Radford Sellers Jun 2020

Building B: Fire And Life Safety Analysis, Joseph Radford Sellers

Fire Protection Engineering: Culminating Experience Project Reports

A fire and life safety analysis was performed on Building B at the Y-12 National Security Complex in Oak Ridge, TN. This report was completed as a fulfillment of one of the requirements for the Masters of Science in Fire Protection Engineering Program from the California Polytechnic State University (Cal Poly) in San Luis Obispo, CA. The analysis consisted of a prescriptive, or code-based analysis, and a performance-based analysis.

The prescriptive analysis composed of four main areas: Life Safety, Fire Alarm and Detection, Structural Fire Protection, and Fire Suppression. The prescriptive analysis was performed to determine if Building B is …


Military Maintenance Hangar, Eliot Jordan Jun 2020

Military Maintenance Hangar, Eliot Jordan

Fire Protection Engineering: Culminating Experience Project Reports

This report describes the building code compliance of a military aircraft hangar. The facility is evaluated for both prescriptive code compliance and for a performance-based compliance via the use of design fires analyzed with computer programs Fire Dynamics Simulator (FDS) and occupant egress analyzed with Pathfinder software as well as hand calculations utilizing Excel.

The prescriptive code analysis is done based upon a combination of Unified Facilities Criteria, International Building Code, and NFPA 101 codes and standards. Prescriptive compliance was checked against the building non separated occupancies of S-1 and B. The building was evaluated for building construction type IIB. …


Cal Poly Engineering Iv Building, Kai Liu Jun 2020

Cal Poly Engineering Iv Building, Kai Liu

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes the fire protection systems of Engineering IV building at California Polytechnic State University, San Luis Obispo. It is a cumulative project of the Fire Protection Engineering Program at Cal Poly. The report consists of a prescriptive analysis and a performance-based design analysis. The building contains dry laboratories, classrooms, offices, and administrative spaces. The building is a three-story structure. There is an atrium that connects the first floor to the third floor. However, the building has a horizontal enclosure to separate the connection between the second floor and the third floor.

The prescriptive analysis is based on the …


New Stanford Hospital, Fpe 2020 Student Mar 2020

New Stanford Hospital, Fpe 2020 Student

Fire Protection Engineering: Culminating Experience Project Reports

This report is the compiled culminating project for the Fire Protection Engineering Master’s Program at Cal Poly, SLO. Addressed herein is the fire protection and life safety approach for the New Stanford Hospital in Palo Alto, California in accordance with the 2012 NFPA 101 – Life Safety Code and the 2016 California Building and Fire Codes. This includes review of building occupancies, construction type, fire-resistive ratings, means of egress, and fire protection systems. The objective of this report is to review the impact of major fire scenarios on life, property, and operations.

The New Stanford Hospital is a Type IA …


Building V: Fire And Life Safety Analysis, Andrew Ko Jun 2019

Building V: Fire And Life Safety Analysis, Andrew Ko

Fire Protection Engineering: Culminating Experience Project Reports

A fire and life safety analysis was completed for Building V as part of a culminating project in the California Polytechnic State University at San Luis Obispo Fire Protection Engineering Master’s Degree Program. This report will detail both a prescriptive design based on the 2013 California Building Code and applicable standards as well as a performance based analysis based on a design fire scenario.

The prescriptive design will discuss four main components of compliance: 1) Structural Fire Protection, 2) Fire Alarm, 3) Fire Sprinkler, and 4) Means of Egress. Structural fire protection analysis is separated into four parts: type of …


Atx Storage: Fire And Life Safety Analysis, Perla Salcedo Jun 2019

Atx Storage: Fire And Life Safety Analysis, Perla Salcedo

Fire Protection Engineering: Culminating Experience Project Reports

The following report is a fire and hazard protection analysis of a new building. This new building is a self-storage building called ATX Storage locate in Austin, TX. The prescriptive requirements set by the codes and standards used at time of construction of the building have been met. The building has been properly classified with respect to occupancy as S1, Group B and R-3 and construction type II A Sprinklered. Appropriate design for interior partitions and exterior wall have been identified. Interior finish requirements have been analyzed for a better understanding of aesthetics guidelines. Based on the sprinkler drawing calculations, …


Fire Protection System Analysis Of Warren J. Baker Center Of Science And Mathematics, Jacob Dentici Jun 2019

Fire Protection System Analysis Of Warren J. Baker Center Of Science And Mathematics, Jacob Dentici

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes the different fire protection systems and features of the Warren J. Baker Center for Science and Mathematics at the California Polytechnic State University, San Luis Obispo campus. This building is used for lectures, laboratories, study spaces, faculty spaces, and storage spaces for the students and faculty at the Cal Poly campus. Typically, there are science and math courses taught within this building. The building is a 6-story structure, that is not classified as a high-rise due to the location of fire department access and has a five-story atrium located on levels 2 through 6. There are two …


Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen Jun 2018

Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen

Fire Protection Engineering: Culminating Experience Project Reports

Analyzing the fire protection features of the Warren J. Baker Center for Science and Mathematics Building 180, located on Cal Poly Campus in San Luis Obispo California was done using two methods. The prescriptive based analysis of the building focused on the building design, egress, structural fire protection, fire suppression, fire alarm and detection systems to determine if current codes and standards were meet. The performance based analysis discusses certain methods and design fire scenarios that are present within the building and the building’s ability to protect occupants until they can exit safely. The performance based analysis was done using …


Life Safety And Fire Analysis - Aircraft Hangar, Frederick J. Tanis Jr. Jun 2018

Life Safety And Fire Analysis - Aircraft Hangar, Frederick J. Tanis Jr.

Fire Protection Engineering: Culminating Experience Project Reports

A hangar originally built in 1958 then modified and expanded over the years was evaluated using both the prescriptive requirements and a performance analysis. For the prescriptive analysis the building was evaluated against the 2015 International Building Code and the current NFPA codes and in a few cases the Department of Defense (DoD) Unified Facilities Criteria (UFC). During the prescriptive analysis a few areas were identified that do not meet the current codes due to areas being broken up into separate rooms and hallways and rooms being separated by security doors that only allow unobstructed travel in one direction. These …


Shyh Wang Hall- Lbnl Building 59, Mike Torkelson Jun 2018

Shyh Wang Hall- Lbnl Building 59, Mike Torkelson

Fire Protection Engineering: Culminating Experience Project Reports

This report details the fire and life safety analysis of Shyh Wang Hall, a new building at the Lawrence Berkeley National Laboratory. Wang Hall houses offices, high performance computers, and associated mechanical space. The building is constructed as a Type IIB structure and includes four stories. Both prescriptive-based and performance-based design is considered.

The prescriptive analysis considers the fire and life safety features as required by applicable codes, including the Department of Energy requirements. The building is protected by fire detection and alarm system as well as automatic sprinklers. The prescriptive design meets the code requirements with the possible exception …