Performance Based Analysis

Articles 1 - 8 of 8

Full-Text Articles in Other Engineering

Elewexe – Building 172b, California Polytechnic State University – San Luis Obispo, Anna M. Santoro Jun 2020

Elewexe – Building 172b, California Polytechnic State University – San Luis Obispo, Anna M. Santoro

Fire Protection Engineering: Culminating Experience Project Reports

California Polytechnic State University at San Luis Obispo recently finished constructing a new multimillion student housing project on campus. One of the six buildings, elewexe or 172B, from this housing complex was selected for a full evaluation of the fire and life safety systems using both prescriptive and performance based approaches. The building is a Type II-B four story dormitory with an R-2 occupancy classification.

For the prescriptive approach, the building was evaluated against the most current editions of the IBC and relevant NFPA code editions for building requirements, sprinkler design and fire alarm and detection. When looking at the …


Fire And Life Safety Analysis: San Francisco Museum Of Modern Art, Jason Woo Jun 2020

Fire And Life Safety Analysis: San Francisco Museum Of Modern Art, Jason Woo

Fire Protection Engineering: Culminating Experience Project Reports

A fire and life safety analysis was conducted to fulfill a requirement for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University. A prescriptive and performance-based analysis was conducted on the San Francisco Museum of Modern Art. The SFMOMA is a 10-story, 460,000 𝑓𝑡2 , Type 1A mixed occupancy building. Located in the northwest corner of San Francisco, SFMOMA houses a collection of over 33,000 works of painting, sculpture, design and media making it one of the largest museums in the world for modern and contemporary art.

Four features of the prescriptive based analysis include: …


Fire Protection And Life Safety Analysis- Building 192 – Engineering Iv, Donald Joseph Wood Jun 2018

Fire Protection And Life Safety Analysis- Building 192 – Engineering Iv, Donald Joseph Wood

Fire Protection Engineering: Culminating Experience Project Reports

A Fire Protection and Life Safety Analysis has been performed on California Polytechnic State University Building 192 – Engineering IV as part of a culminating project in the Masters of Science in Fire Protection Engineering program at California Polytechnic State University. This analysis consists of a prescriptive analysis based on current codes and standards as well as a performance-based analysis.

A prescriptive analysis evaluates compliance with modern codes and standards and consists of the following five parts: 1)Egress Design and Analysis, 2)Structural Fire Protection, 3)Water-based Fire Suppression, 4)Fire Detection and Alarm Systems, and 5)Smoke Control Systems

The purpose of the …


Woodward Willis Building- Fire And Life Safety Evaluation, Jordan Nerat Jun 2017

Woodward Willis Building- Fire And Life Safety Evaluation, Jordan Nerat

Fire Protection Engineering: Culminating Experience Project Reports

This project report is an academic exercise, completed as part of the MS Fire Protection Engineering program at California Polytechnic State University. This project is a culminating report with regards to life safety analysis of the Woodward Willis Building located in Detroit Michigan, which utilizes the fundamental and applied courses of the fire protection engineering program.

The analysis is based on a prescriptive analysis of the building and its features, and also a performance analysis which entails the life safety aspect of the building. The analysis of the building is performed in accordance with NFPA 101 Life Safety Code 2015 …


Fire And Life Safety Evaluation Of The Christopher Cohan Center, Joakim Midtun Larsen Mar 2017

Fire And Life Safety Evaluation Of The Christopher Cohan Center, Joakim Midtun Larsen

Fire Protection Engineering: Culminating Experience Project Reports

This project is an academic exercise, as part of the MS Fire Protection Engineering program of California Polytechnic State University. The project is a culminating report with regards to life safety analysis of the Christopher Cohan Center of Cal Poly, which builds on the fundamental and applied courses of the program. The analysis is twofold, where the first part is a Prescriptive Analysis of the building and its features, followed by a Performance Based Life Safety Analysis. Both parts are performed in accordance with NFPA 101 Life Safety Code 2015 edition, Codes/Standards references within NFPA 101, and supplemented by methods …


Eric W. Rood Administration Center- Fire Protection And Life Safety Analysis, Clinton M. Carman Jun 2016

Eric W. Rood Administration Center- Fire Protection And Life Safety Analysis, Clinton M. Carman

Fire Protection Engineering: Culminating Experience Project Reports

A Fire Protection & Life Safety Analysis was conducted in order to fulfill the requirements for the degree of Master of Science in Fire Protection Engineering. The Fire Protection & Life Safety Analysis consisted of a prescriptive and performance-based analysis of the Eric Rood Administration Center (Rood Center).

The prescriptive based analysis was conducted to determine if the Rood Center adhered to the applicable codes and standards. It utilized the 2013 California Building and Fire Codes and the 2012 Life Safety Code (NFPA 101). Other NFPA codes that were referenced included the 2013 edition of NFPA 13, Standard for the …


Fire And Life Safety Analysis Bonderson Engineering Projets Center, Gary Dominguez Jun 2015

Fire And Life Safety Analysis Bonderson Engineering Projets Center, Gary Dominguez

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety Analysis was performed as one of the requirements for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University San Luis Obispo. The Fire and Life Safety Analysis consists of a prescriptive analysis as well as a performance based analysis. These analyses were performed on the Bonderson Engineering Projects Center which is part of Cal Poly San Luis Obispo. The prescriptive analysis consisted of the four following parts: Egress Analysis and Design, Fire Detection and Alarm Systems, Water-based Fire Suppression, and Structural Fire Protection. The purpose of the prescriptive analysis was …


Fire Protection Analysis Of Campus Building, Mackenzie Hill Jun 2013

Fire Protection Analysis Of Campus Building, Mackenzie Hill

Fire Protection Engineering: Culminating Experience Project Reports

A prescriptive and performance based analysis has been conducted on a College Campus Building in Southern California. This building is still in the approvals process and has been designed to meet the design standards in the 2010 California Building Code (CBC) and relevant NFPA codes. The building is proposed to be the center of operations as well as having administration facilities for the College. It will house an administrative office, production and support facilities. The project is three stories and includes a balcony that does not qualify as a story. The top floor is greater than 30 feet from grade …