Fire Protection Engineering: Culminating Experience Project Reports

Sprinkler

Publication Year

Articles 1 - 4 of 4

Full-Text Articles in Other Engineering

Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger Jun 2023

Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger

Fire Protection Engineering: Culminating Experience Project Reports

Enclosed in this report is a comprehensive analysis of the fire protection and life safety components of the Illinois Department of Transportation (IDOT) District Six Headquarters building. The original building was constructed in 1972 and renovation operations were recently completed in 2022. The building is four stories in height with an aggregate floor area of approximately 69,300 square feet. The building functions as an office space for IDOT staff, therefore the majority of floor space is used as open office and private office space. The business spaces are supported by assembly spaces such as conference and break rooms on each …


An Analysis Of The Life Safety And Fire Protection Features Of A New Hotel On California’S Central Coast, James Henahan Jun 2018

An Analysis Of The Life Safety And Fire Protection Features Of A New Hotel On California’S Central Coast, James Henahan

Fire Protection Engineering: Culminating Experience Project Reports

This report examines the fire protection and life safety features of a new, 3-story plus basement, hotel on California’s Central Coast. These features are examined from both a prescriptive, code-driven perspective, as well as from a performance-based design point of view.

The prescriptive analysis includes exit configuration and capacity, the NFPA 13 sprinkler system, the NFPA 72 fire alarm system, and the building construction types. All were found to be acceptable when compared against the applicable codes the building is subject to, with the exception of some of the load- bearing exterior walls.

The performance-based component examines the affect two …


Culminating Project- U.S. Federal Courthouse, Joshua W. Elvove Jun 2013

Culminating Project- U.S. Federal Courthouse, Joshua W. Elvove

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to select and evaluate a building for compliance with prescriptive and performance based requirements, that apply the concepts learned from previous courses taken as part of the master’s fire protection engineering degree curriculum at Cal Poly, San Luis Obisbo. The report discusses applicable code requirements for building construction, egress, fire alarm initiation and notification, and fire suppression and evaluates the building’s performance, including occupant movement, when subjected to two assumed fires. Fire Dynamics Simulator (FDS) was used to generate data used during the performance analysis. The performance analysis reveals that meeting prescriptive requirements doesn’t …


Life Safety Report Xyz Office Building Denver Colorado, Keith Dix Jun 2013

Life Safety Report Xyz Office Building Denver Colorado, Keith Dix

Fire Protection Engineering: Culminating Experience Project Reports

This report is a Life Safety Analysis of the XYZ building in Colorado. It is a government contract facility and as such prefers that its real name and location not be utilized for this report. The building was assessed prescriptively using the 2009 International Building Code (IBC) and was found to be predominantly compliant with the code and the relevant referenced standards. The building was then assessed using a Performance Based Design in accordance with methodologies found and addressed in common fire protection literature. The Design Criteria chosen to determine tenability for the Required Safe Egress Time (RSET) were Carbon …