Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Engineering

Objective Estimation Of Tracheoesophageal Speech Quality, Yousef S Ettomi Ali Dec 2019

Objective Estimation Of Tracheoesophageal Speech Quality, Yousef S Ettomi Ali

Electronic Thesis and Dissertation Repository

Speech quality estimation for pathological voices is becoming an increasingly important research topic. The assessment of the quality and the degree of severity of a disordered speech is important to the clinical treatment and rehabilitation of patients. In particular, patients who have undergone total laryngectomy (larynx removal) produce Tracheoesophageal (TE) speech. In this thesis, we study the problem of TE speech quality estimation using advanced signal processing approaches. Since it is not possible to have a reference (clean) signal corresponding to a given TE speech (disordered) signal, we investigate in particular the non-intrusive techniques (also called single-ended or blind approaches) …


Investigation Of Visual Perceptions In Parkinson's Disease And The Development Of Disease Monitoring Software, Matthew Bernardinis Aug 2019

Investigation Of Visual Perceptions In Parkinson's Disease And The Development Of Disease Monitoring Software, Matthew Bernardinis

Electronic Thesis and Dissertation Repository

Non-motor Parkinson’s Disease (PD) symptoms are substantial factors of PD arising throughout disease stages, yet their diagnosis and monitoring remain a challenge. Sensory abnormalities in PD occur across sensory systems and disease stages, contributing to disease-related impairments. However, the extent of symptoms is unknown, with inadequate monitoring and treatment options furthering disease management difficulties. The current work studies movement-independent visual perceptions of time, displacement and velocity in PD patients across disease stages using levodopa, deep brain stimulation (DBS), or no PD therapy. Perceptual tasks were conducted using a computer-generated graphical device designed with a focus on simplicity and flexibility. Perception …


Parkinsonian Speech And Voice Quality: Assessment And Improvement, Amr Gaballah Aug 2019

Parkinsonian Speech And Voice Quality: Assessment And Improvement, Amr Gaballah

Electronic Thesis and Dissertation Repository

Parkinson’s disease (PD) is the second most common neurodegenerative disease. Statistics show that nearly 90% of people impaired with PD develop voice and speech disorders. Speech production impairments in PD subjects typically result in hypophonia and consequently, poor speech signal-to-noise ratio (SNR) in noisy environments and inferior speech intelligibility and quality. Assessment, monitoring, and improvement of the perceived quality and intelligibility of Parkinsonian voice and speech are, therefore, paramount. In the first study of this thesis, the perceived quality of sustained vowels produced by PD patients was assessed through objective predictors. Subjective quality ratings of sustained vowels were collected from …


Quantifying The Outcomes Of A Virtual Reality (Vr)-Based Gamified Neck Rehabilitation, Shahan Salim Aug 2019

Quantifying The Outcomes Of A Virtual Reality (Vr)-Based Gamified Neck Rehabilitation, Shahan Salim

Electronic Thesis and Dissertation Repository

Neck pain is a major global public health concern and adds a significant financial burden to both the healthcare system as well as people suffering from it. Additionally, it presents measurement and evaluation challenges for clinicians as well as adherence challenges and treatment barriers for the patients. We have developed a virtual reality (VR)-based video game that can be used to capture outcomes that may aid in the assessment and treatment of neck pain. We investigated: (i) performance metrics of overall accuracy, accuracy based on movement difficulty, duration, and total envelope of movement; (ii) stability across sessions; (iii) accuracy across …


Application Of Electrostatic Dry Powder Coating Technology On Hard Capsules, Zhehao Jing Jul 2019

Application Of Electrostatic Dry Powder Coating Technology On Hard Capsules, Zhehao Jing

Electronic Thesis and Dissertation Repository

This project applied electrostatic dry powder coating technology on hard gelatin and HPMC capsules using Eudragit® RS/RL and Eudragit® L 100-55 to achieve sustained release and enteric release respectively. Dry powder coating eliminated the difficulties associated with conventional liquid coating processes such as poor adhesion and stickiness for capsules. Additionally, through optimizing sprayed plasticizer volume, the coating powders deposited on the capsules could be efficiently maximized. The weight gain of coating and the formulation of coating materials were important parameters which controlled the release profiles of coated capsules. The release mechanism of coated capsules was quite different from …


Improving Material Mapping In Glenohumeral Finite Element Models: A Multi-Level Evaluation, Nikolas K. Knowles Apr 2019

Improving Material Mapping In Glenohumeral Finite Element Models: A Multi-Level Evaluation, Nikolas K. Knowles

Electronic Thesis and Dissertation Repository

An improved understanding of glenohumeral bone mechanics can be elucidated using computational models derived from computed tomography data. Although computational tools, such as finite element analysis, provide a powerful quantitative technique to evaluate and answer a variety of biomechanical and clinical questions, glenohumeral finite element models (FEMs) have not kept pace with improvements in modeling techniques or model validation methods seen in other anatomic locations. The present work describes the use of multi-level computational modeling to compare, develop and validate FEMs of the glenohumeral joint.

Common density-modulus relationships within the literature were evaluated using a multi-level comparative testing methodology to …


Hard, Soft And Off-The-Shelf Foot Orthoses And Their Effect On The Angle Of The Medial Longitudinal Arch: A Biplane Fluoroscopy Study, Megan E.R. Balsdon, Colin E. Dombroski, Kristen Bushey, Thomas Jenkyn Feb 2019

Hard, Soft And Off-The-Shelf Foot Orthoses And Their Effect On The Angle Of The Medial Longitudinal Arch: A Biplane Fluoroscopy Study, Megan E.R. Balsdon, Colin E. Dombroski, Kristen Bushey, Thomas Jenkyn

Mechanical and Materials Engineering Publications

Background: Foot orthoses have proven to be effective for conservative management of various pathologies. Pathologies of the lower limb can be caused by abnormal biomechanics such as abnormal foot structure and alignment, leading to inadequate support. Objectives: To compare biomechanical effects of different foot orthoses on the medial longitudinal arch (MLA) during dynamic gait using skeletal kinematics. Study Design: Prospective, cross-sectional study design. Methods: The MLA angle was measured for 12 participants among three groups: pes planus, pes cavus and normal arch. Five conditions were compared: three orthotic devices (hard custom foot orthosis (CFO), soft CFO, and off-the-shelf Barefoot Science©), …


Development Of In Situ Forming Hydrogels For Intra-Articular Drug Delivery, Andy Prince Feb 2019

Development Of In Situ Forming Hydrogels For Intra-Articular Drug Delivery, Andy Prince

Electronic Thesis and Dissertation Repository

Hydrogels are 3-dimensional crosslinked polymer networks that can absorb significant amounts of water. The physical properties associated with hydrogels affords them resemblance to biological tissues making them good candidates for biomedical applications. Many pharmaceuticals, specifically non-steroidal anti-inflammatory drugs (NSAIDs), have poor aqueous solubility, which limits their bioavailability and efficacy. People suffering from chronic osteoarthritis (OA) are required to frequently take large doses to mitigate pain, which can lead to serious side effects. Hydrogels are good strategies to deliver NSAIDs via articular injection because they can form solid gels in situ. This thesis describes the synthesis, formulation, mechanical testing, in …


Dynamic Light Scattering Optical Coherence Tomography To Probe Motion Of Subcellular Scatterers., Nico J J Arezza, Marjan Razani, Michael C Kolios Feb 2019

Dynamic Light Scattering Optical Coherence Tomography To Probe Motion Of Subcellular Scatterers., Nico J J Arezza, Marjan Razani, Michael C Kolios

Medical Biophysics Publications

Optical coherence tomography (OCT) is used to provide anatomical information of biological systems but can also provide functional information by characterizing the motion of intracellular structures. Dynamic light scattering OCT was performed on intact, control MCF-7 breast cancer cells and cells either treated with paclitaxel to induce apoptosis or deprived of nutrients to induce oncosis. Autocorrelations (ACs) of the temporal fluctuations of OCT intensity signals demonstrate a significant decrease in decorrelation time after 24 h in both the paclitaxel-treated and nutrient-deprived cell groups but no significant differences between the two groups. The acquired ACs were then used as input for …