Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Publication
- Publication Type
- File Type
Articles 1 - 4 of 4
Full-Text Articles in Engineering
Noncontact Diffuse Correlation Tomography Of Human Breast Tumor, Lian He, Yu Lin, Chong Huang, Daniel Irwin, Margaret M. Szabunio, Guoqiang Yu
Noncontact Diffuse Correlation Tomography Of Human Breast Tumor, Lian He, Yu Lin, Chong Huang, Daniel Irwin, Margaret M. Szabunio, Guoqiang Yu
Biomedical Engineering Faculty Publications
Our first step to adapt our recently developed noncontact diffuse correlation tomography (ncDCT) system for three-dimensional (3-D) imaging of blood flow distribution in human breast tumors is reported. A commercial 3-D camera was used to obtain breast surface geometry, which was then converted to a solid volume mesh. An ncDCT probe scanned over a region of interest on the mesh surface and the measured boundary data were combined with a finite element framework for 3-D image reconstruction of blood flow distribution. This technique was tested in computer simulations and in vivo human breasts with low-grade carcinoma. Results from computer simulations …
3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner
3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner
Richard A. Malthaner
The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …
3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner
3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner
Richard A. Malthaner
The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …
In Vivo Mri Signatures Of Hippocampal Subfield Pathology In Intractable Epilepsy., Maged Goubran, Boris C Bernhardt, Diego Cantor-Rivera, Jonathan C Lau, Charlotte Blinston, Robert R Hammond, Sandrine De Ribaupierre, Jorge G Burneo, Seyed M Mirsattari, David A Steven, Andrew G Parrent, Andrea Bernasconi, Neda Bernasconi, Terry M Peters, Ali R Khan
In Vivo Mri Signatures Of Hippocampal Subfield Pathology In Intractable Epilepsy., Maged Goubran, Boris C Bernhardt, Diego Cantor-Rivera, Jonathan C Lau, Charlotte Blinston, Robert R Hammond, Sandrine De Ribaupierre, Jorge G Burneo, Seyed M Mirsattari, David A Steven, Andrew G Parrent, Andrea Bernasconi, Neda Bernasconi, Terry M Peters, Ali R Khan
Robarts Imaging Publications
OBJECTIVES: Our aim is to assess the subfield-specific histopathological correlates of hippocampal volume and intensity changes (T1, T2) as well as diff!usion MRI markers in TLE, and investigate the efficacy of quantitative MRI measures in predicting histopathology in vivo.
EXPERIMENTAL DESIGN: We correlated in vivo volumetry, T2 signal, quantitative T1 mapping, as well as diffusion MRI parameters with histological features of hippocampal sclerosis in a subfield-specific manner. We made use of on an advanced co-registration pipeline that provided a seamless integration of preoperative 3 T MRI with postoperative histopathological data, on which metrics of cell loss and gliosis were quantitatively …