Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 14 of 14

Full-Text Articles in Engineering

Identifying And Predicting Rat Behavior Using Neural Networks, Jonathan A. Gettner Dec 2015

Identifying And Predicting Rat Behavior Using Neural Networks, Jonathan A. Gettner

Master's Theses

The hippocampus is known to play a critical role in episodic memory function. Understanding the relation between electrophysiological activity in a rat hippocampus and rat behavior may be helpful in studying pathological diseases that corrupt electrical signaling in the hippocampus, such as Parkinson’s and Alzheimer’s. Additionally, having a method to interpret rat behaviors from neural activity may help in understanding the dynamics of rat neural activity that are associated with certain identified behaviors.

In this thesis, neural networks are used as a black-box model to map electrophysiological data, representative of an ensemble of neurons in the hippocampus, to a T-maze, …


The Effects Of Transcutaneous Electrical Neurostimulation On Analgesia And Peripheral Perfusion, Leah I. Schafer Dec 2015

The Effects Of Transcutaneous Electrical Neurostimulation On Analgesia And Peripheral Perfusion, Leah I. Schafer

Master's Theses

Peripheral arterial occlusive disease (PAOD) affects 8 to 12 million Americans over the age of 50. As the disease progresses, arterial occlusions arising from atherosclerotic lesions inhibit normal metabolic vasodilation in the peripheries, resulting in limb ischemia and claudication. Pharmacological and surgical treatments currently used to treat both the hemodynamic and pain symptoms associated with PAOD can involve adverse and potentially life-threatening side effects. Thus, there is a need for additional innovative therapies for PAOD.

Neurostimulation has a known analgesic effect on both acute and chronic pain. Although the exact mechanisms remain under investigation, local vascular tone may be modulated …


Modeling Viscoelastic Behavior In Compact Bone Through A Distribution Of Collagen D-Spacing: A Finite Element Analysis, Christopher Ha Nov 2015

Modeling Viscoelastic Behavior In Compact Bone Through A Distribution Of Collagen D-Spacing: A Finite Element Analysis, Christopher Ha

Master's Theses

Osteoporosis affects nearly 54 million people in the United States. The cost associated with treatment is estimated to be $19 billion per year and is expected to grow yearly. D-spacing is the staggering of collagen molecules found at the nanoscopic level. Previously thought to have a constant value, recent studies have found that D-spacing has a distribution of values throughout the tissue. As part of an ongoing effort in understanding the mechanisms that are affected by osteoporosis, a finite element model was developed to explore the effects of D-spacing distribution on the viscoelastic material properties of bone tissue. The goal …


Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani Oct 2015

Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani

Master's Theses

Blood flow velocity is an important parameter that can give information on several pathologies including atherosclerosis, glaucoma, Raynaud’s phenomenon, and ischemic stroke [2,5,6,10]. Present techniques of measuring blood flow velocity involve expensive procedures such as Doppler echocardiography, Doppler ultrasound, and magnetic resonance imaging [11,12]. They cost from $8500-$20000. It is desired to find a low-cost yet equally effective solution for measuring blood flow velocity. This thesis has a goal of creating a proof of concept device for measuring blood flow velocity.

Finger blood flow velocity is investigated in this project. The close proximity to the skin of the finger’s arteries …


Characterization Of Electrophorectic Separations On A Cellulose Paper-Microfluidic Chip, Kyle Robert Fast Sep 2015

Characterization Of Electrophorectic Separations On A Cellulose Paper-Microfluidic Chip, Kyle Robert Fast

Master's Theses

The purpose of this thesis project is to demonstrate the ability to utilize electrophoresis in a cellulose paper microfluidic chip to manipulate charged particles. Materials were selected and a manufacturing protocol was created to successfully apply the electric field onto the paper chip. Experiments were performed to characterize the separation rates for charged, colorimetric dye, Orange G in the membrane as a function of an applied electric field, dye concentration, and distance traveled. The experiments confirmed that the electric field can be applied to the chip and particle separation rates were characterized. Next, the determined rates results were used to …


Design Of A Non-Contact Home Monitoring System For Audio Detection Of Infant Apnea, Daniel T. White Aug 2015

Design Of A Non-Contact Home Monitoring System For Audio Detection Of Infant Apnea, Daniel T. White

Master's Theses

Infant apnea is a widespread condition in which infants fail to effectively breathe, and can lead to death. Clinical solutions exist for continuous monitoring of respirations in a hospital setting and requiring constant skin contact. This thesis investigates the construction of a proof of concept device that performs in-home monitoring without skin contact and with commonly available off-the-shelf components.

The device constructed used a directional microphone to detect breathing sounds, an omnidirectional microphone to detect ambient noise as a baseline to help isolate the breathing sounds, and LabVIEW software deployed on an inexpensive laptop computer to quantify incidents of apparent …


Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon Jun 2015

Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon

Master's Theses

This thesis designed and fabricated various devices that were interfaced to an IC for an active contact lens that notifies the user of an event by detection of an external wireless signal. The contact lens consisted of an embedded antenna providing communication with a 2.4GHz system, as well as inductive charging at an operating frequency of 13.56 MHz. The lens utilized a CBC005 5µAh thin film battery by Cymbet and a manufactured graphene super capacitor as a power source. The custom integrated circuit (IC) was designed using the On Semiconductor CMOS C5 0.6 µm process to manage …


Micro Electrostatic Actuation Of A Silicon Diaphragm, Matthew W. Samples Jun 2015

Micro Electrostatic Actuation Of A Silicon Diaphragm, Matthew W. Samples

Master's Theses

There are a number of applications, from hearing aids to microfluidic pumps, which utilize micro-scale actuating diaphragms. These MEMS (micro-electromechanical system) devices can be actuated by electrostatic forces, which utilize an induced electric field to pull two charged plates towards one another. Such devices were fabricated and electrostatic actuation of the diaphragms was performed to analyze its viability as a micro-speaker. The long-term performance of such products requires adequate diaphragm deflection to create audible pressure waves with relatively low maximum stresses to ensure a high cycle fatigue life. With these requirements, initial calculations and FEA (finite element analysis) were performed …


A Finite Element Analysis On The Viscoelasticity Of Postmenopausal Compact Bone Utilizing A Complex Collagen D-Spacing Model, Austin C. Cummings Jun 2015

A Finite Element Analysis On The Viscoelasticity Of Postmenopausal Compact Bone Utilizing A Complex Collagen D-Spacing Model, Austin C. Cummings

Master's Theses

The nanoscale dimension known as D-spacing describes the staggering of collagen molecules, which are fundamental to the biphasic makeup of bone tissue. This dimension was long assumed to be constant, but recent studies have shown that the periodicity of collagen is variable. Given that the arrangement of collagen molecules is closely related to the degree of bone mineralization, recent studies have begun to look at D-spacing as a potential factor in the ongoing effort to battle postmenopausal osteoporosis. The theoretical models presented by previous studies have only opted to model a single collagen-hydroxyapatite period, so the creation of an intricate …


Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals, Nicholas Czapla Jun 2015

Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals, Nicholas Czapla

Master's Theses

Osteoarthritis (OA) is a degenerative condition of articular cartilage that affects more than 25 million people in the US. Joint injuries, like anterior cruciate ligament (ACL) tears, can lead to OA due to a change in articular cartilage loading. Gait analysis combined with knee joint finite element modeling (FEM) has been used to predict the articular cartilage loading. To predict the change of articular cartilage loading during gait due to various ACL injuries, a tibiofemoral FEM was developed from magnetic resonance images (MRIs) of a 33 year male, with no prior history of knee injuries. The FEM was validated for …


Analysis Of Particles Thorough The Aortic Arch During Transcatheter Aortic Valve Replacement, Andrew Joseph Janicki Jun 2015

Analysis Of Particles Thorough The Aortic Arch During Transcatheter Aortic Valve Replacement, Andrew Joseph Janicki

Master's Theses

Ischemia caused by particles becoming dislodged during transcatheter aortic valve replacement (TAVR) is a possible complication of TAVR. The particles that become dislodged can travel out of the aortic valve, into the aortic arch, and then into either the brachiocephalic artery, the left common carotid artery, the left subclavian artery or continue into the descending aorta. If the particles continue into the descending aorta it poses no risk of causing ischemia however if it travels into the other arteries then it increases the possibility of the particle causing an ischemic event. The goal of this study is to determine what …


Characterization Of Two Vernier-Tuned Distributed Bragg Reflector (Vt-Dbr) Lasers Used In Swept Source Optical Coherence Tomography (Ss-Oct), Greg M. Bergdoll Jun 2015

Characterization Of Two Vernier-Tuned Distributed Bragg Reflector (Vt-Dbr) Lasers Used In Swept Source Optical Coherence Tomography (Ss-Oct), Greg M. Bergdoll

Master's Theses

Insight Photonic Solutions Inc. has continued to develop their patented VT-DBR laser design; these wavelength tunable lasers promise marked image-quality and acquisition time improvements in SS-OCT applications.

To be well suited for SS-OCT, tunable lasers must be capable of producing a highly linear wavelength sweep across a tuning range well-matched to the medium being imaged; many different tunable lasers used in SS-OCT are compared to identify the optimal solution.

This work electrically and spectrally characterizes two completely new all-semiconductor VT-DBR designs to compare, as well. The Neptune VT-DBR, an O-band laser, operates around the 1310 nm range and is a …


Evaluating The Effectiveness Of Cranial Molding For Treatment Of Positional Plagiocephaly Using Finite Element Analysis, Maziyar Keshtgar May 2015

Evaluating The Effectiveness Of Cranial Molding For Treatment Of Positional Plagiocephaly Using Finite Element Analysis, Maziyar Keshtgar

Master's Theses

Since the advent of recommendations for placing infants in the supine position during sleep to reduce the incidence of sudden infant death syndrome, clinicians have noted an increase in the frequency of cranial asymmetry due to deformation of suture sections of the infants’ skulls as a result of constant concentrated stress in one area at the back of their head. This specific form of cranial deformation is known as positional plagiocephaly and its rate of occurrence has increased from 0.3% in 8.2% within the past 30 years.

Current treatments and methodologies for preventing and correcting positional plagiocephaly such as stretching …


Comparison Of Regular Ringer's Solution And Glucose Ringer's Solution On The Longevity Of The Hirudo Medicinalis' Retzius Cell, Nicole Arielle Peretti Mar 2015

Comparison Of Regular Ringer's Solution And Glucose Ringer's Solution On The Longevity Of The Hirudo Medicinalis' Retzius Cell, Nicole Arielle Peretti

Master's Theses

In 1882, Sydney Ringer, a professor of medicine at University College in London, experimented with the frog ventricle to better understand how each constituent of blood influences contraction. The ultimate goal was to create an artificial circulating fluid to use for the perfusion of isolated organs, in this case, a frog heart. Today, Ringer’s solution is still used in research for physiological studies requiring the survival and maintenance of specimens outside of their host bodies. One such example is the use of medicinal leech ganglia for electrophysiological measurements. In this thesis, I am comparing two Ringer’s solutions, original versus added …