Full-Text Articles in Engineering

Development Of A Rigid Body Computational Model For Investigation Of Wrist Biomechanics, Benjamin Majors Dec 2010

Development Of A Rigid Body Computational Model For Investigation Of Wrist Biomechanics, Benjamin Majors

Theses and Dissertations

The wrist is one of the most complex joints in the human body. As such, the wrist joint is difficult to model due to the number of bones involved and its intricate soft tissue interactions. Many studies have attempted modeling the wrist previously; however, the majority of these studies simplify the joint into two-dimensions or idealized mechanical joints to reduce the complexity of the simulation. While these approaches still yield valuable information, the omission of a third-dimension or geometry defined movements limits the models’ usefulness in predicting joint function under non-idealized conditions. Therefore, the goal of this study was to …


Modeling Of Aortic Valve Anatomic Geometry From Clinical Multi Detector-Row Computed Tomography Images, Gregory A. Book Dec 2010

Modeling Of Aortic Valve Anatomic Geometry From Clinical Multi Detector-Row Computed Tomography Images, Gregory A. Book

Master's Theses

Transcatheter aortic valve implantation (TAVI) is an emerging and viable alternative to surgical valve replacement. A TAVI procedure involves insertion of a catheter into the heart through an artery or transapically, and expanding valve stent in place. This procedure dramatically reduces the recovery time by eliminating the need for open heart surgery. Understanding the biomechanics of the stent-valve interaction is crucial for proper device deployment and function. In this study, we examine the extraction of valve geometries and creation of valve models from multi-detector row computed tomography (MDCT) images that may eventually be used to model stent expansion on a …


Incorporating Feedback From Multiple Sensory Modalities Enhances Brain–Machine Interface Control, Aaron J. Suminski, Dennis C. Tkach, Andrew H. Fagg, Nicholas G. Hatsopoulos Dec 2010

Incorporating Feedback From Multiple Sensory Modalities Enhances Brain–Machine Interface Control, Aaron J. Suminski, Dennis C. Tkach, Andrew H. Fagg, Nicholas G. Hatsopoulos

Biomedical Engineering Faculty Research and Publications

The brain typically uses a rich supply of feedback from multiple sensory modalities to control movement in healthy individuals. In many individuals, these afferent pathways, as well as their efferent counterparts, are compromised by disease or injury resulting in significant impairments and reduced quality of life. Brain–machine interfaces (BMIs) offer the promise of recovered functionality to these individuals by allowing them to control a device using their thoughts. Most current BMI implementations use visual feedback for closed-loop control; however, it has been suggested that the inclusion of additional feedback modalities may lead to improvements in control. We demonstrate for the …


Mapping The Flip Angle In Magnetic Resonance Imaging Using The Accelerated 3d Look-Locker Sequence, Trevor P. Wade Dec 2010

Mapping The Flip Angle In Magnetic Resonance Imaging Using The Accelerated 3d Look-Locker Sequence, Trevor P. Wade

Electronic Thesis and Dissertation Repository

In the ongoing quest to extract more information from MRI images, there has arisen a need to rapidly map the flip angle. This has been primarily driven by the shift to stronger main field strengths, which bring with them improved SNR, but also new difficulties. In particular, the radio frequency field used to excite the magnetization can no longer be assumed uniform at field strengths of 3 Tesla and above. New rapid quantitative imaging techniques, such as DESPOT1 and DESPOT2, rely on accurate knowledge of the flip angle, and while this could safely be assumed to be the prescribed value …


4-D Modeling Of Displacement Vector Fields For Improved Radiation Therapy, Elizabeth Zachariah Dec 2010

4-D Modeling Of Displacement Vector Fields For Improved Radiation Therapy, Elizabeth Zachariah

Theses and Dissertations

In radiation therapy, it is imperative to deliver high doses of radiation to the tumor while reducing radiation to the healthy tissue. Respiratory motion is the most significant source of errors during treatment. Therefore, it is essential to accurately model respiratory motion for precise and effective radiation delivery. Many approaches exist to account for respiratory motion, such as controlled breath hold and respiratory gating, and they have been relatively successful. They still present many drawbacks. Thus, research has been expanded to tumor tracking. This paper presents a spatio-temporal model for four dimensional CT reconstruction. The method begins with a set …


Modeling Heat Transfer During Cooling Of Ready-To-Eat Meat And Poultry Products Using Three-Dimensional Finite Element Analysis And Web-Based Simulation, Jihan F. Cepeda Jimenez Dec 2010

Modeling Heat Transfer During Cooling Of Ready-To-Eat Meat And Poultry Products Using Three-Dimensional Finite Element Analysis And Web-Based Simulation, Jihan F. Cepeda Jimenez

Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research

The meat industry is required to comply with processing performance standards for preventing the growth of foodborne pathogens in products. These performance standards, established by the United States Department of Agriculture - Food Safety and Inspection Service (USDA-FSIS) require a reduction of Salmonella spp (lethality standard) and limit the growth of sporeforming bacteria (stabilization standard) in certain processed meat products. In general, strategies used to comply with these standards are associated with thermal processing. Meat processors have difficulties complying with these performance standards. Moreover, thermal processing deviations are an issue in the meat industry that generate uncertainty regarding the safety …


Synthesis And Characterization Of Electrospun Gelatin/Dendrimer Scaffold Encapsulated With A Silver As A Potential Antimicrobial Wound Dressing, Alpana Dongargaonkar Dec 2010

Synthesis And Characterization Of Electrospun Gelatin/Dendrimer Scaffold Encapsulated With A Silver As A Potential Antimicrobial Wound Dressing, Alpana Dongargaonkar

Theses and Dissertations

A novel nanofiber scaffold was fabricated and characterized as a potential antimicrobial wound dressing. Half generation polyamidoamine (PAMAM) dendrimer G3.5 was covalently conjugated to gelatin. Gelatin alone or with gelatin-dendrimer conjugates was electrospun into nanofiber scaffolds. Gelatin is a derivative of natural collagen, and it is biocompatible, non-toxic and inexpensive, making it a desirable component in a wound dressing. Dendrimers are synthetic polymers comprising of a central core, internal branches and reactive surface groups. They provide a structurally controlled architecture for drug release. Silver was incorporated into the scaffold in situ due to its broad spectrum of antimicrobial properties. The …


Development Of Electroencephalography Based Brain Controlled Switch And Nerve Conduction Study Simulator Software, Kai Qian Dec 2010

Development Of Electroencephalography Based Brain Controlled Switch And Nerve Conduction Study Simulator Software, Kai Qian

Theses and Dissertations

This thesis investigated the development of an EEG-based brain controlled switch and the design of a software for nerve conduction study. For EEG-based brain controlled switch, we proposed a novel paradigm for an online brain-controlled switch based on Event-Related Synchronizations (ERDs) following external sync signals. Furthermore, the ERD feature was enhanced by 3 event-related moving averages and the performance was tested online. Subjects were instructed to perform an intended motor task following an external sync signal in order to turn on a virtual switch. Meanwhile, the beta-band (16-20Hz) relative ERD power (ERD in reverse value order) of a single EEG …


Development Of An Integrated Soil Properties Mapping System, Rajveer S. Dhillon Dec 2010

Development Of An Integrated Soil Properties Mapping System, Rajveer S. Dhillon

Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research

One of the main goals of precision agriculture (PA) is to define spatial variability in soil properties within an agricultural field to make decisions that can maximize profitability and reduce negative environmental impact. Various soil sensor systems have been developed over the years to map soil properties on-the-go. In this study, an Integrated Soil Mapping System (ISMS) was developed to predict soil water content, soil organic matter, and soil mechanical resistance on-the-go using a capacitance moisture sensor, an optical sensor, and a load cell sensor respectively. These sensors were mounted on the ISMS for acquiring three different data layers at …


A Microfluidic Device To Establish Concentration Gradients Using Reagent Density Differences, Qingjun Kong, Richard A. Able, Jr., Veronica Dudu, Maribel Vazquez Dec 2010

A Microfluidic Device To Establish Concentration Gradients Using Reagent Density Differences, Qingjun Kong, Richard A. Able, Jr., Veronica Dudu, Maribel Vazquez

Publications and Research

Microfabrication has become widely utilized to generate controlled microenvironments that establish chemical concentration gradients for a variety of engineering and life science applications. To establish microfluidic flow, the majority of existing devices rely upon additional facilities, equipment, and excessive reagent supplies, which together limit device portability as well as constrain device usage to individuals trained in technological disciplines. The current work presents our laboratory-developed bridged microLane system, which is a stand-alone device that runs via conventional pipette loading and can operate for several days without need of external machinery or additional reagent volumes. The bridged microLane is a two-layer polydimethylsiloxane …


Characterization And Analysis Techniques Of A Dynamic In Vitro Blood-Brain Barrier Model, Ryan Everett Woodhouse Dec 2010

Characterization And Analysis Techniques Of A Dynamic In Vitro Blood-Brain Barrier Model, Ryan Everett Woodhouse

Biomedical Engineering

The blood-brain barrier (BBB) is responsible for maintaining the sensitive environment required by the brain. Although the BBB is necessary for proper functioning of the brain, it acts as an obstacle for doctors attempting to treat neurological disease. For a drug to act upon the brain, it must first pass through the discriminating BBB. For this reason, much research has been performed in recent years in order to create an in vitro model of the BBB on which drugs targeted for the central nervous system may be tested. The main goal of this project is to create an in vitro …


Singular Value Decomposition Metrics Show Limitations Of Detector Design In Diffuse Fluorescence Tomography, Frederic Leblond, Kenneth M. Tichauer, Brian W. Pogue Dec 2010

Singular Value Decomposition Metrics Show Limitations Of Detector Design In Diffuse Fluorescence Tomography, Frederic Leblond, Kenneth M. Tichauer, Brian W. Pogue

Dartmouth Scholarship

The spatial resolution and recovered contrast of images reconstructed from diffuse fluorescence tomography data are limited by the high scattering properties of light propagation in biological tissue. As a result, the image reconstruction process can be exceedingly vulnerable to inaccurate prior knowledge of tissue optical properties and stochastic noise. In light of these limitations, the optimal source-detector geometry for a fluorescence tomography system is non-trivial, requiring analytical methods to guide design. Analysis of the singular value decomposition of the matrix to be inverted for image reconstruction is one potential approach, providing key quantitative metrics, such as singular image mode spatial …


Identification Of Holocarboxylase Synthetase Chromatin Binding Sites In Human Mammary Cell Lines Using The Damid Technology, Dipika Singh Dec 2010

Identification Of Holocarboxylase Synthetase Chromatin Binding Sites In Human Mammary Cell Lines Using The Damid Technology, Dipika Singh

Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research

Holocarboxylase synthetase (HCS) is a chromatin protein that is essential for mediating the covalent binding of biotin to histones. Biotinylation of histones plays crucial roles in the repression of genes and repeats in the human genome. The objective of this project was to determine genomic binding sites of holocarboxylase synthetase (HCS) in the human chromatin of breast cell lines using an antibody independent technology. We tested the feasibility of DNA adenine methyltransferase identification (DamID) technology to map HCS binding sites in human mammary cell lines. Full-length HCS was fused to Dam for subsequent transfection into breast cancer (MCF-7) and normal …


Novel Vascular Grafts Based On Polyphenol-Stabilized Acellular Tissue Scaffolds, Ting-Hsien Chuang Dec 2010

Novel Vascular Grafts Based On Polyphenol-Stabilized Acellular Tissue Scaffolds, Ting-Hsien Chuang

All Dissertations

The Cardiovascular diseases (CVDs) continue to be the leading cause of morbidity and mortality worldwide. The most common form of CVDs is occlusion of blood flow thus limiting blood supply to specific tissues or organs. Atherosclerosis is a leading cause of coronary heart disease and stroke, which were responsible for more than 25% of deaths in 2004.
The demand for vascular graft is huge. In United States alone, approximately 500,000 coronary artery bypass graft surgeries are performed annually. Synthetic polymers such as Dacron and ePTFE have been successfully applied in large diameter blood vessel prosthesis; however, for small diameter (inner …


Modulated Properties Of Fully Absorbable Bicomponent Meshes, Shawn Peniston Dec 2010

Modulated Properties Of Fully Absorbable Bicomponent Meshes, Shawn Peniston

All Dissertations

Current meshes used for soft-tissue repair are mostly composed of single component, nonabsorbable yarn constructions, limiting the ability to modulate their properties. This situation has left the majority of soft tissue repair load-bearing applications to suffer distinctly from undesirable features associated, in part, with mesh inability to (1) possess short-term stiffness to facilitate tissue stability during the development of wound strength; (2) gradually transfer the perceived mechanical load as the wound builds mechanical integrity; and (3) provide compliance with load transfer to the remodeling and maturing mesh/tissue complex. The likelihood of long-term complications is reduced for fully absorbable systems with …


Evaluation Of Factors That Modulate Cellular Adipogenesis For Breast Tissue Engineering Strategies, Cheryl Gomillion Dec 2010

Evaluation Of Factors That Modulate Cellular Adipogenesis For Breast Tissue Engineering Strategies, Cheryl Gomillion

All Dissertations

It is estimated that this year more than 200,000 women in the United States will be diagnosed with breast cancer. Treatment for most occurrences of breast cancer will often include surgical removal of the tumorigenic tissue, resulting in a soft tissue defect within the subcutaneous tissue of the skin. Post-surgical reconstruction methods are often sought by patients to restore the aesthetic function of the breast via cellular or non-cellular methods; however, because of complications associated with currently used methods for breast reconstruction, researchers are investigating tissue engineering methods to produce viable autologous adipose tissue for breast reconstruction.
Previous research in …


An Investigation Of Process Parameters To Optimize The Fiber Diameter Of Electrospun Vascular Scaffolds Through Experimental Design, Steffi Wong Dec 2010

An Investigation Of Process Parameters To Optimize The Fiber Diameter Of Electrospun Vascular Scaffolds Through Experimental Design, Steffi Wong

Biomedical Engineering

No abstract provided.


Vena Cava As An Alternative To Pericardium In Bioprosthetic Percutaneous Heart Valves, Amy Munnelly Dec 2010

Vena Cava As An Alternative To Pericardium In Bioprosthetic Percutaneous Heart Valves, Amy Munnelly

All Theses

Valve disease is a specialized form of cardiovascular disease that specifically affects the heart valves. Heart valves serve the vital function of maintaining unidirectional blood flow through the chambers of the heart during the cardiac cycle; however, as valve disease progresses, this function can become severely compromised [1]. Currently, the only cure for valve disease is to replace the defective valve with an engineered substitute. Each year, over 300,000 heart valve replacement surgeries are performed worldwide [2], and this number is expected to continue growing as life expectancies increase [3].
In the United States, the most common form of valve …


Correction To Mitochondrial Free [Ca2+] Increases During Atp/Adp Antiport And Adp Phosphorylation: Exploration Of Mechanisms, Johan Haumann, Ranjan K. Dash, David F. Stowe, Age D. Boelens, Daniel A. Beard, Amadou K.S. Camara Dec 2010

Correction To Mitochondrial Free [Ca2+] Increases During Atp/Adp Antiport And Adp Phosphorylation: Exploration Of Mechanisms, Johan Haumann, Ranjan K. Dash, David F. Stowe, Age D. Boelens, Daniel A. Beard, Amadou K.S. Camara

Biomedical Engineering Faculty Research and Publications

No abstract provided.


Aortic Coarctation: Recent Developments In Experimental And Computational Methods To Assess Treatments For This Simple Condition, John F. Ladisa, Charles A. Taylor, Jeffrey A. Feinstein Dec 2010

Aortic Coarctation: Recent Developments In Experimental And Computational Methods To Assess Treatments For This Simple Condition, John F. Ladisa, Charles A. Taylor, Jeffrey A. Feinstein

Biomedical Engineering Faculty Research and Publications

Coarctation of the aorta (CoA) is often considered a relatively simple disease, but long-term outcomes suggest otherwise as life expectancies are decades less than in the average population and substantial morbidity often exists. What follows is an expanded version of collective work conducted by the authors' and numerous collaborators that was presented at the 1st International Conference on Computational Simulation in Congenital Heart Disease pertaining to recent advances for CoA. The work begins by focusing on what is known about blood flow, pressure and indices of wall shear stress (WSS) in patients with normal vascular anatomy from both clinical imaging …


Influence Of Topography Of Endovascular Stent Material On Smooth Muscle Cell Response, Vipul Taneja Dec 2010

Influence Of Topography Of Endovascular Stent Material On Smooth Muscle Cell Response, Vipul Taneja

All Theses

Although implantation of endovascular stents for the treatment of coronary and peripheral artery diseases has been one of the most rapidly used medical interventions, significant limitations in terms of a restenosis rate of 10-30% still persists. Neointimal hyperplasia characterized by a phenotypic shift of smooth muscle cells from contractile to synthetic type, has been deemed to be the predominant cause of restenosis. A number of stent surface parameters, including topography, have been attributed to play an important role in stent performance. Although endothelial cell and thrombotic response to surface roughness have been well evaluated, the effect of topography of the …


Neomycin-Enhanced Carbodiimide Cross-Linking For Glycosaminoglycan Stability In Bioprosthetic Heart Valves, Joshua Leong Dec 2010

Neomycin-Enhanced Carbodiimide Cross-Linking For Glycosaminoglycan Stability In Bioprosthetic Heart Valves, Joshua Leong

All Theses

Valvular heart diseases lead to over 290,000 heart valve replacements worldwide each year, and approximately half of these involve replacement with a bioprosthetic heart valve (BHV) [1]. BHVs exhibit excellent hemocompatibility, but suffer from inadequate long-term durability with most adult implanted valves failing within 12 to 15 years after implantation [2]. Although this may be adequate for some individuals, BHV implantation may be contraindicated in younger individuals to avoid reoperation. Even in elder recipients, valve dysfunction can still cause death or reoperation that could be avoided with increased BHV durability. Therefore, investigation into methods of increasing BHV durability can not …


Experimental And Computational Analysis Of An Energy Storage Composite Ankle Foot Orthosis, Michelle C. Hawkins Dec 2010

Experimental And Computational Analysis Of An Energy Storage Composite Ankle Foot Orthosis, Michelle C. Hawkins

UNLV Theses, Dissertations, Professional Papers, and Capstones

Ankle Foot Orthotics (AFOs) are used by individuals presenting with Charcot-Marie-Tooth (CMT) to assist with improving gait. Mitch Warner, CPO, has developed a composite AFO made from woven carbon-Kevlar and carbon fiber lamina. The overall goals of the research are to characterize the HELIOS brace and to determine its effect on the gait of CMT subjects. Human motion analysis, experimental mechanical testing, and Finite Element Analysis (FEA) are used to gain a better understanding of how the materials and geometric design of the HELIOS AFO contribute to gait.


Human motion experiments are performed to determine the relationship between ground reaction …


Development Of Software To Estimate Pressures On The Residual Limbs Of Amputees By Means Of A Pylon Mounted Transducer, Malli K. Yalamanchili Dec 2010

Development Of Software To Estimate Pressures On The Residual Limbs Of Amputees By Means Of A Pylon Mounted Transducer, Malli K. Yalamanchili

UNLV Theses, Dissertations, Professional Papers, and Capstones

The alignment of prosthesis has been recognized as one of the main factors that determine successful prosthetic outcomes for trans-tibial amputees. Alignment is defined as the relative position and orientation of the prosthetic components. Misalignment can result in changes in the position and orientation of the joints of the leg and moments experienced by them during gait, increases in energy use, and discomfort or even tissue breakdown at the socket/stump interface. Hence it is very important to align the prosthesis in correct manner. Gait analysis can be used to examine the effects of incorrect alignment of the prosthesis during gait. …


Characterization Of Anti-Proteolytic And Anti-Proliferative Activities Of Pentagalloylglucose; Its Potential Application As A Therapeutic Agent In Vascular Diseases, Chaitra Cheluvaraju Dec 2010

Characterization Of Anti-Proteolytic And Anti-Proliferative Activities Of Pentagalloylglucose; Its Potential Application As A Therapeutic Agent In Vascular Diseases, Chaitra Cheluvaraju

All Dissertations

Cardiovascular diseases are the leading causes of mortality in the United States and will cost around $500 billion this year alone. Elevated proteolytic activity, increased proliferation and migration of vascular smooth muscle cells are hallmarks of atherosclerosis, stenosis and aortic aneurysms. These diseases often manifest the transdifferentiation of vascular smooth muscle cells into osteoblast-like cells followed by deposition of hydroxyapatite–like mineral in the arterial walls.
Currently, there are no standard treatments available for vascular calcification or aneurysms. Atherosclerosis treatment options are limited to statins while balloon angioplasty and stenting – surgical procedures for stenosis, often end in restenosis. Therefore, we …


New Tools For Monitoring Gamma Camera Uniformity, Brad K. Lofton Dec 2010

New Tools For Monitoring Gamma Camera Uniformity, Brad K. Lofton

Dissertations & Theses (Open Access)

Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any …


The Development And Validation Of A Finite Element Model Of A Canine Rib For Use With A Bone Remodeling Algorithm., Scott J. Sylliaasen Dec 2010

The Development And Validation Of A Finite Element Model Of A Canine Rib For Use With A Bone Remodeling Algorithm., Scott J. Sylliaasen

Master's Theses

Studies are currently being performed to determine the effects of bisphosphonate treatments on the structure and density of bone tissue. One of the pathways for gaining a better understanding of the effects of this and other treatments involves creating a computer simulation. Theory suggests that bone tissue structure and density are directly related to the manner in which the tissue is loaded. Remodeling is the process in which bone tissue is resorbed in areas of low stress distributions, and generated in areas of high stress distributions. Previous studies have utilized numerical methods and finite element methods to predict bone structure …


Assessment Of Morphology And Hemodynamics In Normal And Remodeled Microvasculature With Parameter Sensitivity Analysis, Shilpi Ghosh Dec 2010

Assessment Of Morphology And Hemodynamics In Normal And Remodeled Microvasculature With Parameter Sensitivity Analysis, Shilpi Ghosh

Master's Theses

The goal of this study was to compare the morphological and hemodynamic characteristics of normal and remodeled vascular networks in the mouse gracilis muscle. To this end, previously developed models to assess flows and vascular branching were used to assess the normal and remodeled microcirculatory networks. The analysis revealed that the average individual vessel flow rates for vessels of similar caliber and total volumetric flow rates in the networks do not change for vessels of the same caliber after remodeling. Connectivity changes and average diameters primarily change in the larger arterioles after remodeling. A few correlations could be made between …


Hydraulic Conductivity, Infiltration, And Runoff From No-Till And Tilled Cropland, Jessica H. Deck Dec 2010

Hydraulic Conductivity, Infiltration, And Runoff From No-Till And Tilled Cropland, Jessica H. Deck

Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research

Infiltration and runoff are important processes that affect the efficiency of center pivot irrigation systems. No-till planting systems potentially influence the hydraulic properties of soils and the soil surface conditions. The result of long-term use of no-till could be higher infiltration and lower runoff from rainfall and irrigation.

This potential was investigated in Nebraska on two center pivot irrigated sites; Fillmore County and Phelps County, one furrow irrigated site; South Central Agriculture Laboratory (SCAL), and one dryland site; Rogers Farm. Paired treatments were used at each location, one that was no-till planted and one that used two to three operations …


Characterization And Evaluation Of A Novel Tissue Engineered Aortic Heart Valve Construct, Mary Tedder Dec 2010

Characterization And Evaluation Of A Novel Tissue Engineered Aortic Heart Valve Construct, Mary Tedder

All Dissertations

Tissue engineering holds great promise for treatment of valvular diseases. Scaffolds for engineered heart valves must function immediately after implantation, but must also permit repopulation with autologous host cells and facilitate gradual remodeling.
Native aortic heart valves are composed of three layers, i.e. two strong external fibrous layers (ventricularis and fibrosa) separated by a central, highly hydrated spongiosa. The fibrous layers provide strength and resilience while the spongiosa layer facilitates shearing of the external layers. Our working hypothesis is that partially cross-linked collagen scaffolds that closely mimic the layered histo-architecture of the native valve would fulfill these requirements. To test …