Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

2010

Architectural Engineering

Institution
Keyword
Publication
Publication Type

Articles 1 - 19 of 19

Full-Text Articles in Engineering

Interpretations Of Sustainability In Higher Education, Omidreza Saadatian Nov 2010

Interpretations Of Sustainability In Higher Education, Omidreza Saadatian


No abstract provided.


Culvert Material Cost Comparison, New England Environmental Finance Center Nov 2010

Culvert Material Cost Comparison, New England Environmental Finance Center

Water

The following tables provide a detailed look at the role that culvert material and culvert diameter play in the overall cost of a culvert replacement project.


An Investigation Of The Influence Of Diaphragm Flexibility On Building Design Through A Comparison Of Forced Vibration Testing And Computational Analysis, Blake Alan Roskelley Nov 2010

An Investigation Of The Influence Of Diaphragm Flexibility On Building Design Through A Comparison Of Forced Vibration Testing And Computational Analysis, Blake Alan Roskelley

Master's Theses

An assessment of the validity of idealizing a concrete diaphragm as rigid was performed through the modal analysis of three existing buildings. Modal analysis was performed both by physical experimentation and computational analysis. Experimental determination of the mode shapes shows that two of the three buildings’ diaphragms exhibited flexible behavior. The experimental results were compared to computational analysis results and were shown to be similar, confirming that that the two building diaphragms are not rigid. As a standard, diaphragms with aspect ratios less than three are permitted to be idealized as rigid per ASCE 7-05. To determine the effect of …


Culvert Material Cost Comparison, New England Environmental Finance Center Nov 2010

Culvert Material Cost Comparison, New England Environmental Finance Center

Economics and Finance

The following tables provide a detailed look at the role that culvert material and culvert diameter play in the overall cost of a culvert replacement project. Table 1 displays the cost per foot purchase price arranged by diameter size for the various culvert materials that are currently available. Table 2 displays the average additional culvert pipe material cost (increased cost to upsize minus original in-kind replacement cost) that would be incurred when upsizing a given diameter of culvert with a 50 foot length by factors of: 200%, 250% and 300%.


Performance Comparison Of Control Methods For Tankless Water Heaters, David P. Yuill, Andrew H. Coward, Gregor P. Henze Aug 2010

Performance Comparison Of Control Methods For Tankless Water Heaters, David P. Yuill, Andrew H. Coward, Gregor P. Henze

David Yuill

Tankless water heaters (TWH) have several advantages and disadvantages when compared with storage water heaters. One disadvantage is that the outlet temperature of the water is difficult to control. To address this problem, the authors apply seven different control approaches and con- duct experiments to test the effectiveness of each approach. The experiments are carried out on a commercially available electric TWH, using a test method and apparatus developed by the authors. The seven approaches include various configurations of feedback or feed-forward con- trol, or both. One fairly simple approach devised in this project combines feedback and feed-forward control. This …


Intricacies Of Professional Certifications For Quality Management (Qm), Edmund R. Martelli Aug 2010

Intricacies Of Professional Certifications For Quality Management (Qm), Edmund R. Martelli

Masters Theses & Specialist Projects

The modern manufacturing marketplace is extremely complex and constantly changing. Career professionals often seek job placement, career advancement, and continuing education through professional certifications. Professional certifications in the United States (U.S.) have been evolving since 1911. In the 1950s, engineering groups established professional certifications and licenses. In the 1980s, administration of accreditation of certification programs proliferated, and by the 1990s, many government and professional organizations sought to standardize procedures for the industry. Currently, professional certifications are available for virtually every profession and issued by multitudes of organizations.

Quality management (QM) encompasses an extensive combination ofprofessional abilities. Providers of professional certifications …


Cyber-Physical Codesign Of Distributed Structural Health Monitoring With Wireless Sensor Networks, Gregory Hackmann, Weijun Guo, Guirong Yan, Chenyang Lu, Shirley Dyke Jul 2010

Cyber-Physical Codesign Of Distributed Structural Health Monitoring With Wireless Sensor Networks, Gregory Hackmann, Weijun Guo, Guirong Yan, Chenyang Lu, Shirley Dyke

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Our Deteriorating Civil Infrastructure Faces the Critical Challenge of Long-Term Structural Health Monitoring for Damage Detection and Localization. in Contrast to Existing Research that Often Separates the Designs of Wireless Sensor Networks and Structural Engineering Algorithms, This Paper Proposes a Cyber-Physical Co-Design Approach to Structural Health Monitoring based on Wireless Sensor Networks. Our Approach Closely Integrates (1) Flexibility-Based Damage Localization Methods that Allow a Tradeoff between the Number of Sensors and the Resolution of Damage Localization, and (2) an Energy-Efficient, Multi-Level Computing Architecture Specifically Designed to Leverage the Multi-Resolution Feature of the Flexibility-Based Approach. the Proposed Approach Has Been Implemented …


Structural Damage Detection Robust Against Time Synchronization Errors, Guirong Yan, Shirley J. Dyke May 2010

Structural Damage Detection Robust Against Time Synchronization Errors, Guirong Yan, Shirley J. Dyke

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Structural Damage Detection based on Wireless Sensor Networks Can Be Affected Significantly by Time Synchronization Errors among Sensors. Precise Time Synchronization of Sensor Nodes Has Been Viewed as Crucial for Addressing This Issue. However, Precise Time Synchronization over a Long Period of Time is Often Impractical in Large Wireless Sensor Networks Due to Two Inherent Challenges. First, Time Synchronization Needs to Be Performed Periodically, Requiring Frequent Wireless Communication among Sensors at Significant Energy Cost. Second, Significant Time Synchronization Errors May Result from Node Failures Which Are Likely to Occur during Long-Term Deployment over Civil Infrastructures. in This Paper, a Damage …


Determination Of Material Emission Signatures By Ptr-Ms And Their Correlations With Odor Assessments By Human Subjects, Kwanghoon Han Apr 2010

Determination Of Material Emission Signatures By Ptr-Ms And Their Correlations With Odor Assessments By Human Subjects, Kwanghoon Han

Kwanghoon Han

The objectives of this study were to determine volatile organic compound (VOC) emission signatures of nine typical building materials by using proton transfer reaction-mass spectrometry (PTR-MS) and to explore the correlation between the PTR-MS measurements and the measurements of acceptability by human subjects. VOC emissions from each material were measured in a 50-l small-scale chamber. Chamber air was sampled by PTR-MS to determine emission signatures. Sorbent tube sampling and TD-GC/MS analysis were also performed to identify the major VOCs emitted and to compare the resulting data with the PTR-MS emission signatures. The data on the acceptability of air quality assessed …


Identification Of Physical Changes To A Steel Frame, Daniel Eric Means Feb 2010

Identification Of Physical Changes To A Steel Frame, Daniel Eric Means

Master's Theses

The thesis utilized physical testing and computer modeling to determine the feasibility of identifying a change to the mass or stiffness of a steel frame. Physical testing was performed using an accelerometer, linear shaker, and arbitrary function generator. Two methods of laboratory testing were developed: ambient vibration testing (AVT) and forced vibration testing (FVT). AVT was able to preliminarily identify the natural frequencies and mode shapes of the frame. FVT was able to precisely identify four distinct natural frequencies, mode shapes, and damping ratios. The baseline frame then underwent two physical changes: the addition of mass to its roof, and …


Evaluation Of A Web-Based Learning Tool For Teaching Gis Within The Context Of Transportation Engineering, Ashley Banaszek, Hong Sheng, Richard H. Hall, Ronaldo Luna, Ghulam Bham Jan 2010

Evaluation Of A Web-Based Learning Tool For Teaching Gis Within The Context Of Transportation Engineering, Ashley Banaszek, Hong Sheng, Richard H. Hall, Ronaldo Luna, Ghulam Bham

Business and Information Technology Faculty Research & Creative Works

An Exploratory Study Was Conducted to Evaluate a Web-Based Learning Module for Teaching Geographic Information Systems to Civil Engineering Students within the Context of a Problem Related to Crash Data Analysis. This Module is One Part of a National Science Foundation Course, Curricula, and Laboratory Improvement Project in Which GIS Modules Are Being Developed for Several Areas of Civil Engineering. the Module Was Used as a Laboratory Assignment in a Transportation Engineering Course. Two Days Later Students Completed Both an Objective Multiple-Choice Quiz over the Material Covered in the Lab and a Subjective Questionnaire. Quantitative Analysis Was Carried Out on …


A Study Of The Economical Feasibility Of Installing Heating, Ventilation, And Air-Conditioning Condensate Recovery System, Rafid M. Kully Jan 2010

A Study Of The Economical Feasibility Of Installing Heating, Ventilation, And Air-Conditioning Condensate Recovery System, Rafid M. Kully

Theses

The objective of this study is to establish a guide line or an analytical frame work to predetermine the economic benefits associated with the installation of Heating, Ventilation, and Air-Conditioning (HVAC) condensate recovery systems to capture the air-handler’s condensate water and use it as makeup water for the cooling tower. Some factors should be considered such as; the location, building operation, amount of outside air required, type of energy recovery system, and indoor conditions setup. Experimental data was used from Emory University in Georgia, where a condensate recovery system was installed and the condensate water from four air-handler units at …


Ab-10-018: The Effects Of Noise From Building Mechanical Systems With Tonal Components On Human Performance And Perception (1322-Rp), Erica E. Ryherd, Lily M. Wang Jan 2010

Ab-10-018: The Effects Of Noise From Building Mechanical Systems With Tonal Components On Human Performance And Perception (1322-Rp), Erica E. Ryherd, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

This study investigated the effects of noise from building mechanical systems with tonal components on human task performance and perception. Six different noise conditions based on in-situ measurements were reproduced in an office-like setting; all were set to approximately the same sound level (47 dBA) but could have one particular tonal frequency (120 Hz, 235 Hz, or 595 Hz) at one of two tonal prominence ratios (5 or 9). Thirty participants were asked to complete typing, grammatical reasoning, and math tasks plus subjective questionnaires, while being exposed for approximately 1 hour to each noise condition. Results show that the noise …


Ab-10-017: Combined Effects Of Noise And Temperature On Human Comfort And Performance (1128-Rp), Dale Tiller, Lily M. Wang, Amy Musser, Matthew Radik Jan 2010

Ab-10-017: Combined Effects Of Noise And Temperature On Human Comfort And Performance (1128-Rp), Dale Tiller, Lily M. Wang, Amy Musser, Matthew Radik

Durham School of Architectural Engineering and Construction: Faculty Publications

This paper summarizes results from an experiment designed to investigate the combined effects of noise and temperature on human thermal comfort and task performance. Thirty subjects (16 females, 14 males) were exposed to all combinations of five thermal conditions (PMV +1 [79.6°F:26.4°C], PMV +0.5 [75.8°F:24.3°C], PMV 0 [72.1°F:22.3°C], PMV -0.5 [68.3°F:20.2°C], and PMV -1 [64.6°F:18.1°C]), three RC noise levels (RC-30, RC-40, and RC-50), and two sound qualities (neutral and rumbly): all sounds mimicked noise from building ventilation systems. After a one-hour adaptation period at each condition, subjects rated their thermal comfort using the ASHRAE Thermal Comfort Scale and the Tenant …


Ab-10-019: Human Performance And Perception-Based Evaluations Of Indoor Noise Criteria For Rating Mechanical System Noise With Time-Varying Fluctuations (1322-Rp), Lily M. Wang, Cathleen C. Novak Jan 2010

Ab-10-019: Human Performance And Perception-Based Evaluations Of Indoor Noise Criteria For Rating Mechanical System Noise With Time-Varying Fluctuations (1322-Rp), Lily M. Wang, Cathleen C. Novak

Durham School of Architectural Engineering and Construction: Faculty Publications

The goal of this study was to investigate the effects of noise from building mechanical systems with time-varying fluctuations on human task performance and perception, and to determine how well current indoor noise rating methods account for this performance and perception. Six different noise conditions with varying degrees of time-varying fluctuations, many focused in the low frequency rumble region, were reproduced in an office-like setting. Thirty participants were asked to complete typing, grammatical reasoning, and math tasks plus subjective questionnaires, while being exposed for approximately one hour to each noise condition. Results show that the noise conditions with higher sound …


Ab-10-C037: Effects Of Noise From Building Mechanical Systems On Elementary School Student Achievement, Lauren M. Ronsse, Lily M. Wang Jan 2010

Ab-10-C037: Effects Of Noise From Building Mechanical Systems On Elementary School Student Achievement, Lauren M. Ronsse, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

This project seeks to determine what relationship, if any, exists betweenbackground noise levels in elementary classrooms due to the building mechanicalsystems and student performance on achievement tests. Previous research inclassroom acoustics has clearly identified that lower background noise levelsresult in higher speech intelligibility which is crucial for the learning process;however, there is a lack of data correlating lower noise levels to improved studentachievement scores. For this study, background noise level measurements were madein 14 elementary schools in a public school system in Council Bluffs, Iowa, USA.The measurements were made in unoccupied classrooms with the central buildingmechanical systems activated. Second and …


Active Noise Barrier Minimizing Pressure Gradient, Carl Hart, Siu-Kit Lau Jan 2010

Active Noise Barrier Minimizing Pressure Gradient, Carl Hart, Siu-Kit Lau

Durham School of Architectural Engineering and Construction: Faculty Publications

Minimization of the sound pressure field within the shadow zone of a noise barrier is achieved by reducing the pressure gradient along a line, at the top of a barrier, via active noise control. The noise control effectiveness of a barrier is increased by this strategy, especially for specific system configurations. The proposed method was evaluated by numerical simulation. Results indicate that system orientation has little effect on minimizing the pressure gradient at the top of the barrier when the error sensors are invisible to the primary noise disturbance. Highly effective control within the shadow zone and close to the …


Noise Propagation Through Open Windows Of Finite Depth Into An Enclosure, Caleb Sieck, Siu-Kit Lau Jan 2010

Noise Propagation Through Open Windows Of Finite Depth Into An Enclosure, Caleb Sieck, Siu-Kit Lau

Durham School of Architectural Engineering and Construction: Faculty Publications

Predicting the insertion loss of an opening backed with an enclosed space is important for building noise control. Recent research in sound transmission through apertures of finite depth in infinite rigid baffles has included the effects of propagating and evanescent modes within the aperture in order to extend models to higher frequencies. The present study extends the model to the case of the aperture backed by a cavity as opposed to sound radiating into half-space. The role of coupling between the aperture modes, radiation modes, and cavity modes in the transmission was investigated. The results were compared to those of …


Feasibility Study Of Solar Driven Underground Cooling System, Michel E. Shafik Jan 2010

Feasibility Study Of Solar Driven Underground Cooling System, Michel E. Shafik

Durham School of Architectural Engineering and Construction: Dissertations, Thesis, and Student Research

In the United States the peak electrical use occurs during the summer. In addition, the building sector consumes a major portion of the annual electrical energy consumption. One of the main energy consuming components in the building sector is the Heating, Ventilation, and Air-Conditioning (HVAC) systems. This research studies the feasibility of implementing a solar driven underground cooling system that could contribute to reducing building cooling loads. The developed system consists of an Earth-to-Air Heat Exchanger (EAHE) coupled with a solar chimney that provides a natural cool draft to the test facility building at the Solar Energy Research Test Facility …