Elementary, Pressure Dependent Model For Combustion Of C1, C2 And Nitrogen Containing Hydrocarbons : Operation Of A Pilot Scale Incinerator And Model Comparison, Chad Sheng
Dissertations
A 140000 BTU/hr pilot scale incinerator has been constructed, tested and run; and an online sampling train capable of taking in situ data has been established. The continuous on-line analytical instruments include a CO analyzer, an NO/NOx analyzer and an 02 analyzer. In addition, two gas chromatographs with flame ionization detector are used to determine CH4, C2H2 + C2H4 and total hydrocarbon concentrations. Typical operating conditions are at an average 02 concentration of 6 - 8 %. The NO concentration ranged from 100 - 200 ppm. Approximately I ppm of CH.4 is also present at steady state operations.
The kinetic …