Analysis Of The Bony Interface With Various Types Of Hydroxyapatite In Vitro, J. D. De Bruijn, J. S. Flach, K. De Groot, C. A. Van Blitterswijk, J. E. Davies Jan 1993

Analysis Of The Bony Interface With Various Types Of Hydroxyapatite In Vitro, J. D. De Bruijn, J. S. Flach, K. De Groot, C. A. Van Blitterswijk, J. E. Davies

Cells and Materials

Rat bone marrow cells, capable of forming bonelike tissue, were cultured on three types of plasma sprayed hydroxyapatite that differed in degree of crystallinity from 15%, 43% to 69%. The interface between the mineralized extracellular matrix and the hydroxyapatite was studied with scanning and transmission electron microscopy. At the onset of bone formation, calcium and phosphorous-rich afibrillar globules, with a diameter varying from 0.2 to 0.8 μm, were produced and deposited onto the different substrata. These globules subsequently fused to form a homogeneous layer to which collagen fibres became anchored. Individual globules could be distinguished on the non-degrading 69 % …


Multinucleated Giant Cells-Hydroxyapatite Interactions: A Time-Related Quantitative Study In A Rat Skull Defect, J. M. Dersot, A. Llorens, J. L. Saffar Jan 1993

Multinucleated Giant Cells-Hydroxyapatite Interactions: A Time-Related Quantitative Study In A Rat Skull Defect, J. M. Dersot, A. Llorens, J. L. Saffar

Cells and Materials

The implantation of calcium phosphate ceramics in the bone environment elicits the differentiation of multinucleated giant cells (MNGCs). MNGC interactions with both crushed and standard hydroxyapatite (HA, Bioapatite ®) particles (cHA and sHA) were studied in rat skull defects. Light microscopy (LM) of undemineralized material after 21 and 42 days of implantation showed that the number of particles in the defect significantly decreased (about SO%) with the two HA forms. Concomitantly, average cHA particle size increased significantly due to the elimination of the smallest particles by the MNGCs. The number of MNGCs per mm2 of defect decreased significantly between 21 …


Immunocytochemical And Lectin-Gold Characterization Of The Interface Between Alveolar Bone And Implanted Hydroxyapatite In The Rat, H. Kawaguchi, M. D. Mckee, H. Okamoto, A. Nanci Jan 1993

Immunocytochemical And Lectin-Gold Characterization Of The Interface Between Alveolar Bone And Implanted Hydroxyapatite In The Rat, H. Kawaguchi, M. D. Mckee, H. Okamoto, A. Nanci

Cells and Materials

The tissue response to implanted hydroxyapatite (HAP) in rat alveolar bone was investigated using morphological and cytochemical approaches. High-resolution immunogold labeling was used to examine the distribution of two non-collagenous bone proteins, osteopontin and osteocalcin, and two plasma proteins, a2HSglycoprotein (fetuin) and albumin. Glycoconjugates were characterized by lectin-gold cytochemistry using Ricinus communis I agglutinin and Wheat germ agglutinin. Transmission electron microscopy demonstrated the presence of an electron-dense, lamina limitans-like layer at the HAP particle-bone interface and organic material within the micropores of the particles. Mineral was observed in relation to both these sites. The HAP particle-bone interface was strongly …


Cell-Degradation Of Calcium Phosphate Ceramics, P. Frayssinet, N. Rouquet, F. Tourenne, J. Fages, D. Hardy, G. Bonel Jan 1993

Cell-Degradation Of Calcium Phosphate Ceramics, P. Frayssinet, N. Rouquet, F. Tourenne, J. Fages, D. Hardy, G. Bonel

Cells and Materials

Calcium phosphate ceramics are used in bone surgery under different forms: dense or porous ceramic s as bone substitute, thin ceramic coatings on metallic implants as an osseointegration enhancer. Their degradation depends on their physico-chemical properties and particularly on their chemical composition. Natural calcium phosphates of bone are degraded by mononuclear or multinuclear cells and the extracellular matrix induces the differentiation of the degrading-cells. Hydroxyapatite, which is one of the most used calcium phosphates , is known as a low degradation material. However, the histological analysis of implanted HA-materials both in animals and in humans showed that a cellular degradation …


Influence Of Crystal Structure On The Establishment Of The Bone-Calcium Phosphate Interface In Vitro, J. D. De Bruijn, C. P. A. T. Klein, K. De Groot, C. A. Van Blitterswijk Jan 1993

Influence Of Crystal Structure On The Establishment Of The Bone-Calcium Phosphate Interface In Vitro, J. D. De Bruijn, C. P. A. T. Klein, K. De Groot, C. A. Van Blitterswijk

Cells and Materials

An in vitro rat bone marrow cell system was used to examine the interfacial ultrastructure established between various calcium phosphates and mineralized tissue. The investigated calcium phosphates comprised hydroxyapatite (HA), fluorapatite (FA), tricalcium phosphate (TCP), tetracalcium phosphate (TECP) and magnesium whitlockite (MWL). Both scanning and transmission electron microscopy were used to examine the elaborated interface. The time in which a mineralized extracellular matrix was formed on the various materials differed from 2 weeks on HA, TCP and TECP, to 8 weeks on FA. It was only occasionally observed in some areas on MWL, which might have been due to aluminum …