Full-Text Articles in Engineering

Improving The Reliability And Accessibility Of Ct Perfusion Imaging In Acute Ischemic Stroke, Kevin J. Chung Feb 2023

Improving The Reliability And Accessibility Of Ct Perfusion Imaging In Acute Ischemic Stroke, Kevin J. Chung

Electronic Thesis and Dissertation Repository

CT perfusion (CTP) imaging is a validated treatment decision support tool in acute ischemic stroke. Automated analysis of CTP cerebral blood flow (CBF) and Tmax maps produces estimates of ischemic core and penumbra volumes used to determine target mismatch profiles for treatment. However, availability and utilization of CTP is low due to diagnostic variability between CTP software and technical, logistical, and radiation dose considerations that may limit its routine adoption. The objective of this doctoral research was to improve the reliability and accessibility of CTP by (1) improving diagnostic agreement between CTP software, (2) enabling perfusion imaging with standard acute …


The Use Of Ct To Assess Shoulder Kinematics And Measure Glenohumeral Arthrokinematics, Baraa Daher Dec 2021

The Use Of Ct To Assess Shoulder Kinematics And Measure Glenohumeral Arthrokinematics, Baraa Daher

Electronic Thesis and Dissertation Repository

Recently, studies have started employing dynamic four-dimensional computed tomography (4DCT) imaging as a biomechanical assessment tool. These studies would benefit from the valuable work that has been done in the past using three-dimensional computed tomography (3DCT). Thus, a structured review was conducted to examine the extent and range of methods employing CT imaging to measure shoulder kinematics. The findings of the review were utilized to conduct a study that employed 4DCT imaging to measure glenohumeral joint congruency and arthrokinematics during internal rotation to the back in a population of healthy individuals. The results of this work show the importance of …


Evaluating And Improving Cochlear Length Measurements On Clinical Computed Tomography Images, John E. Iyaniwura Aug 2017

Evaluating And Improving Cochlear Length Measurements On Clinical Computed Tomography Images, John E. Iyaniwura

Electronic Thesis and Dissertation Repository

Cochlear implants provide the sensation of sound to deaf individuals. An accurate estimate of cochlear duct length (CDL) is required for pre-operative implant electrode selection and can be obtained from clinical computed tomography (CT) by measuring the “A-value”.

The objectives of this work were to estimate the accuracy and variability in manual A-value measurements, and to automate measurements.

Four specialists repeatedly measured the A-value on clinical CT images from which the inter- and intra-observer variability were calculated. Accuracy was assessed by comparison to measurements on higher resolution micro-CT images. Motivated by this study, software was developed to automate the A-value …


Investigation Of In-Vivo Hindfoot And Orthotic Interactions Using Bi-Planar X-Ray Fluoroscopy, Kristen M. Bushey Jun 2012

Investigation Of In-Vivo Hindfoot And Orthotic Interactions Using Bi-Planar X-Ray Fluoroscopy, Kristen M. Bushey

Electronic Thesis and Dissertation Repository

A markerless RSA method was used to determine the effect of orthotics on the normal, pes planus and pes cavus populations. Computed tomography (CT) was used to create bone models that were imported into the virtual environment. Joint coordinate systems were developed to measure kinematic changes in the hindfoot during weight-bearing gait and quiet standing. The objectives of this thesis were to (1) implement a fluoroscopy-based markerless RSA system on the foot, (2) determine the effect of various orthotics at midstance of fully weight-bearing dynamic gait, and (3) determine the effect of orthotics as measured using three different techniques. Every …