Mechanical Evaluation Of Gyroid Structures To Combat Orthopaedic Implant Infections, Sydney Hitchon
Mechanical Evaluation Of Gyroid Structures To Combat Orthopaedic Implant Infections, Sydney Hitchon
Electronic Thesis and Dissertation Repository
Treatment of infected orthopaedic implants often require two separate surgeries to clear the infection and install a replacement implant. Current antimicrobial drug delivery methods are inefficient, and each additional surgery increases the physiologic burden on patients, with an increased risk of infection, decreased range of motion and longer recovery times. Porous orthopaedic implants, with adequate strength for permanent implantation and the ability to house and elude more efficient antibiotic delivery systems, could result in a single surgery to treat orthopaedic infections. Therefore, finite element models of porous gyroid structures at different porosities were developed and compared with experimental results. Discrepancies …