Full-Text Articles in Engineering

Feasibility Of Twisted Coiled Polymer Actuators For Use In Upper Limb Wearable Rehabilitation Devices, Brandon P.R. Edmonds Dec 2020

Feasibility Of Twisted Coiled Polymer Actuators For Use In Upper Limb Wearable Rehabilitation Devices, Brandon P.R. Edmonds

Electronic Thesis and Dissertation Repository

Throughout your lifetime, it is nearly impossible to avoid at least one musculoskeletal condition that requires rehabilitation, and for a world containing billions of people, the costs associated with these conditions have become a huge economic burden. Nevertheless, the scientific community has become increasingly aware of the growing potential for wearable mechatronic systems to assist with upper-limb musculoskeletal rehabilitation; however, one limiting factor to their clinical acceptance lies in the development of actuation solutions. Conventional actuators are rigid and cylindrical in nature, requiring additional features to provide the proper forces, torques, and motion direction, required for human interaction. Another type …


Lanthanide Nanoparticles As Contrast Agents For In Vivo Dual Energy Microcomputed Tomography Of The Mouse Vasculature, Charmainne Cruje Oct 2020

Lanthanide Nanoparticles As Contrast Agents For In Vivo Dual Energy Microcomputed Tomography Of The Mouse Vasculature, Charmainne Cruje

Electronic Thesis and Dissertation Repository

Dual energy (DE) computed tomography (CT) has the capability to influence medicine and pre-clinical research by providing quantitative information that can detect nascent lesions, identify perfusion restoration or inhomogeneities within tissues, and recognize the presence of calcium deposits. A wide variety of instrumentation techniques and scan protocols have been developed for DE CT, with a common goal of acquiring a pair of images that reports the attenuation of a given volume to two different x-ray distributions. While DE image acquisition has benefitted from technical advancements in CT, the contrast agents that are used are still predominantly composed of iodinated small …


Development Of An Active Infection Monitoring Knee Spacer For Two-Stage Revision, Michael K. Lavdas Jul 2020

Development Of An Active Infection Monitoring Knee Spacer For Two-Stage Revision, Michael K. Lavdas

Electronic Thesis and Dissertation Repository

Infections requiring surgical revision occur in ~3% of total knee arthroplasty (TKA) procedures. The standard treatment for TKA infection in North America is referred to as the two-stage revision process. Unfortunately, the success rate of the two-stage revision is low, at roughly 85%. There are indications that the two-stage revision may fail to clear the infection due to unsatisfactory diagnostic tools. This thesis depicts the development and evaluation of a novel telemetric sensing package designed for integration into the two-stage revision process. Studies within evaluate its performance through sensor validation, thermal insulation testing, radio frequency penetration evaluation, a cadaveric loading …


The Of Application Of 3d-Printing To Lumbar Spine Surgery, Andrew J. Kanawati Apr 2020

The Of Application Of 3d-Printing To Lumbar Spine Surgery, Andrew J. Kanawati

Electronic Thesis and Dissertation Repository

Rapid prototyping refers to the manufacturing process in which a three-dimensional (3D) digital model can be transformed into a physical model by layering material in the shape of successive cross sections atop of previously layers. Rapid prototyping has been increasing in popularity in the field of medicine and surgery due to the ability to personalize various aspects of patient care. The thesis will explore the use of rapid prototyping in lumbar spine surgery, aim to quantify the accuracy of medical imaging when relating to imaged structures and their corresponding models produced by rapid prototyping, and determine if complex patient-specific guides …