Articles 1 - 15 of 15

Full-Text Articles in Engineering

Fire Protection Analysis Of Warren J. Baker Center For Science, Aric E. Carracino Jun 2015

Fire Protection Analysis Of Warren J. Baker Center For Science, Aric E. Carracino

Fire Protection Engineering: Culminating Experience Project Reports

A prescriptive and performance based analysis was performed on the Warren J Baker Center for Science on the California Polytechnic San Luis Obispo campus. The code based analysis included reviewing the building’s egress components, structural fire protection, fire sprinkler system, and fire alarm system. This included the requirements of the California Building Code, as well as applicable NFPA codes. Analysis of the egress components of the building revealed several dead end corridors within the building that exceed the maximum allowed length of 50 feet. In addition, the student workspace areas on Level 3 require two exits, but are only provided …


Comprehensive Fire And Life Safety Analysis Of Building 186, Construction Innovation Center, At California Polytechnic State University, San Luis Obispo, Chris Torres Jun 2015

Comprehensive Fire And Life Safety Analysis Of Building 186, Construction Innovation Center, At California Polytechnic State University, San Luis Obispo, Chris Torres

Fire Protection Engineering: Culminating Experience Project Reports

The report summarizes the analysis of the existing fire protection features and systems installed in the Construction Innovation Center at California Polytechnic State University, San Luis Obispo. The center is divided into three individual buildings (Buildings A, B and C) and are connected at each floor by an exterior balcony. The analysis includes two different approaches. A prescriptive analysis approach has been used to examine if the installed fire protection features and systems compliance with the latest edition of the codes and standards in California. This approach includes an evaluation of the fire structure protection, means of egress, fire alarm …


Fire Protection Analysis Cotchett Education Building, Building 002, Cal Poly San Luis Obispo, William J. Beasland Jun 2015

Fire Protection Analysis Cotchett Education Building, Building 002, Cal Poly San Luis Obispo, William J. Beasland

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes the Cotchett Education Building on the Cal Poly, San Luis Obispo College campus. Since this is an existing building, with various modifications made during the life of the building, it was analyzed as an existing building. NFPA 101, Life Safety Code, 2012 edition (LSC) contains requirements for existing buildings, and was the primary code used in this analysis. Other codes used in analysis were referenced in each section. The Cotchett Education Building meets most requirements of NFPA 101, Life Safety Code, 2012 edition. However, there are recommendations regarding exiting and the alarm system. See section 7 of …


Fire Protection Engineering Analysis For Building 910 - Sandia National Labs/Ca, Mo Mosallaei Jun 2015

Fire Protection Engineering Analysis For Building 910 - Sandia National Labs/Ca, Mo Mosallaei

Fire Protection Engineering: Culminating Experience Project Reports

This Fire Protection Engineering analysis was performed on Building 910 in Sandia National Laboratories in Livermore, CA to examine the building’s fire safety and fire protection criteria which originally adhered to the 1985 Uniform Building Code. The object of this analysis is to determine the degree of compliance with the prescriptive codes in place today as well compliance with performance based analysis. For the prescriptive analysis consisted of evaluating the buildings occupancy classification, type of construction, egress design, fire detection and alarm systems, fire sprinkler system, Halon System, and structural fire protection are evaluated in terms of the life safety …


Fire Protection And Life Safety Analysis Of A Modern Distributon Facility, Nolan Mccarthy Jun 2015

Fire Protection And Life Safety Analysis Of A Modern Distributon Facility, Nolan Mccarthy

Fire Protection Engineering: Culminating Experience Project Reports

Warehouse facilities are part of the backbone of American industry. The vast amounts of varying goods stored and distributed as part of American business has always driven the need for large, voluminous warehouses. And the increasing size of these facilities over the decades is very closely linked to the capabilities of and advances in fire protection knowledge and technology. Today’s modern distribution centers easily and often exceed one million square feet in area, and the heights are ever increasing. In the 1970’s and early 1980’s, most warehouse facilities were built to an approximate height of 30 feet; this, at the …


Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes Jun 2015

Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes

Fire Protection Engineering: Culminating Experience Project Reports

This is an analysis of a 1970’s vintage building as it is compared to current building codes and standards. The purpose of this document is to assess if the current, as found construction of an existing building could achieve the sometimes more restrictive modern building codes. Both a prescriptive analysis and a performance-based analysis were completed to verify life-safety concerns and criteria as well as construction criteria. The prescriptive analysis compared existing, as found construction to current codes and standards while the prescriptive analysis used modern fire modeling techniques to see how likely fire scenarios would challenge the structure, if …


Comprehensive Fire Protection And Life Safety Evaluation Of The Robotic Manufacturing Science And Engineering Laboratories (Rmsel) Facility, Tomas M. Sanchez Jun 2015

Comprehensive Fire Protection And Life Safety Evaluation Of The Robotic Manufacturing Science And Engineering Laboratories (Rmsel) Facility, Tomas M. Sanchez

Fire Protection Engineering: Culminating Experience Project Reports

A comprehensive fire protection and life safety evaluation has been performed for the Robotic Manufacturing Science and Engineering Laboratory (RMSEL) at Sandia National Laboratories (SNL). The evaluation considered both prescriptive and performance based aspects. Current codes, such as the 2012 International Building Code and the 2013 version of NFPA 13 – Standard for the Installation of Sprinkler Systems, are generally the basis for the prescriptive evaluation even though they are not the code of record for the building. Use of current codes for this evaluation is mostly for academic reasons. Nevertheless, the facility is generally compliant with the provisions of …


Fire And Life Safety Analysis Bonderson Engineering Projets Center, Gary Dominguez Jun 2015

Fire And Life Safety Analysis Bonderson Engineering Projets Center, Gary Dominguez

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety Analysis was performed as one of the requirements for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University San Luis Obispo. The Fire and Life Safety Analysis consists of a prescriptive analysis as well as a performance based analysis. These analyses were performed on the Bonderson Engineering Projects Center which is part of Cal Poly San Luis Obispo. The prescriptive analysis consisted of the four following parts: Egress Analysis and Design, Fire Detection and Alarm Systems, Water-based Fire Suppression, and Structural Fire Protection. The purpose of the prescriptive analysis was …


Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer Jun 2015

Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer

Fire Protection Engineering: Culminating Experience Project Reports

This fire and life safety report covers a Battalion Headquarters Complex that is used for housing military troops. This is a complete review of the building with prescriptive based fire protection along with performance base review of the building. The prescriptive fire protection covers egress analysis of the space, passive fire protection (i.e. fire walls and doors) and active fire protection (i.e. fire alarm and fire sprinklers). The performance based section looks at the prescriptive requirements and sees if these would be enough for the application at hand. The building fire protection and life safety are covered by three different …


Fire And Life Safety Evaluation & Analysis- Bonderson Engineering Projects Center, Garrett Brown Mar 2015

Fire And Life Safety Evaluation & Analysis- Bonderson Engineering Projects Center, Garrett Brown

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety Analysis of the Bonderson Engineering Projects Center, (BEPC) Building 197 on the California Polytechnic State University, San Luis Obispo (Cal Poly) Campus is performed. Both prescriptive and performance based methods and metrics are utilized to evaluate the facility with respect to current fire and building standards and codes. Prescriptive fire protection features and systems analyzed include: building construction type and design, structural fire protection features and requirements, occupancy classification and egress analysis, fire detection, alarm, and communication systems, and fire suppression systems The prescriptive based design requirements largely met the code and installation requirements with …


Laboratory Building- Sandia National Laboratories, Albuquerque, Nm, Joshua Herrera Mar 2015

Laboratory Building- Sandia National Laboratories, Albuquerque, Nm, Joshua Herrera

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of the culminating report was to perform a prescriptive-based and performance-based analysis on the fire and life safety systems in the laboratory building at Sandia National Laboratories (SNL). The prescriptive-based analysis determined if the laboratory building met applicable code requirements for life safety systems. The performance-based analysis conducted a series of fire scenarios to ensure the fire and life safety systems provided adequate egress time for occupants in the event of a fire. The prescriptive-based analysis was based on the Life Safety Code (LSC) and International Building Code (IBC). The laboratory building is a mixed occupancy building. The …


Culminating Project Report- Warren J. Baker Center For Science And Mathematics, Blake Johnson Mar 2015

Culminating Project Report- Warren J. Baker Center For Science And Mathematics, Blake Johnson

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes the fire protection features of the Warren J. Baker Center for Science and Mathematics on the Cal Poly San Luis Obispo campus in San Luis Obispo, CA. The prescriptive analysis of the structural fire protection, egress, fire suppression, and fire alarm, detection, and communication systems shows that the building meets the requirements of current codes and standards. The performance based analysis includes simulating design fire scenarios in the atrium using computer modeling (CFAST, FDS) and the results of these models show that the atrium meets the tenability criterion for the calculated evacuation time of occupants.


Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller Mar 2015

Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze Building 310 with regards to fire and life safety. Analysis was done both prescriptively and from a performance based design standpoint. The prescriptive based analysis includes review of the building’s design with regards to egress, fire alarm systems, suppression systems, and structural fire protection. The building was reviewed against current NFPA codes and the International Building Code to examine compliance. The performance-based analysis consists of two different fire scenarios that were examined. The goal was to show that the building met safety criteria and does not pose undue risk to occupants. This …


Fire Protection And Life Safety Engineering Analysis- Center For Science And Mathematics, Orelvis Gonzalez Cruz Mar 2015

Fire Protection And Life Safety Engineering Analysis- Center For Science And Mathematics, Orelvis Gonzalez Cruz

Fire Protection Engineering: Culminating Experience Project Reports

The Life Safety and Fire Protection systems in Cal Poly’s Center for Science and Mathematics (CSM) were analyzed and evaluated in this project, according to the requirements of the applicable codes and pertinent standards. The evaluation was conducted through a prescriptive-based approach, in conjunction with a performance-based approach. On one hand, the prescriptive-based approach considered the analysis of the Structural Fire Protection and Means of Egress in the building and the existing Fire Detection/Alarm and Fire Suppression Systems. On the other hand, the performance-based approach included an Egress Analysis, which assessed the Required Safe Egress Time (RSET) and the Available …


Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott Mar 2015

Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott

Fire Protection Engineering: Culminating Experience Project Reports

This report covers both a prescriptive and performance-based review of fire and life safety systems for the Solar Energy Research Center at the Lawrence Berkeley National Laboratory. The primary subjects covered are egress, fire alarm systems, and sprinkler systems. A unique feature and focal point for this report is the SERC east exit stair. This stair was originally designed as a glass atrium, but for various reasons cannot be utilized as an atrium. The east exit stair has a special VESDA detection system, is the most remote location for the sprinkler system, and is a primary exit for all three …