Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 2 of 2
Full-Text Articles in Engineering
The Effects Of Heat Treatment On Area Percent Porosity And Corrosion Behavior Of High-Nickel Thermal Spray Coatings, Travis Crowe, Alec Guraydin
The Effects Of Heat Treatment On Area Percent Porosity And Corrosion Behavior Of High-Nickel Thermal Spray Coatings, Travis Crowe, Alec Guraydin
Materials Engineering
Samples of two Thermal Spray Coating (TSC) alloys on a low carbon steel substrate were obtained: alloy C276 and Nicko-Shield 200. Specimens of each alloy were subjected to heat treatments at temperatures at 1100° for 60 minutes and 1200° for 10 minutes, with some specimens left in the as-sprayed condition. Three replicates were prepared for each condition. Thin 1” strips were cut using a diamond wafering blade for porosity measurements and 2” x 1” specimens were cut for corrosion testing using a SiC abrasive saw. The porosity specimens were mounted in acrylic resin, polished, and examined using SEM. From these …
Characterization Of The Relationship Between The Microstructure And Tensile Strength Of Annealed Ti-6al-4v, Aldo Corona
Characterization Of The Relationship Between The Microstructure And Tensile Strength Of Annealed Ti-6al-4v, Aldo Corona
Materials Engineering
Tensile coupons of Ti-6Al-4V were heat treated at varying annealing temperatures from 1200°F (648°C) to 1450°F (787°C) at 50°F (23°C) increments for 1 hour. The samples were air cooled to room temperature or furnace cooled to 800°F (426°C) followed by air cooling to room temperature. Four tensile coupons were treated at each annealing temperature and cooling rate. Alpha case was observed to form on the surface of the samples post heat treatment with a maximum depth of 25 µm (.001 in). Samples were tensile tested for their ultimate tensile strength, yield strength, and percent elongation. Samples across all annealing temperatures …