Fire Protection Engineering: Culminating Experience Project Reports

Fire Alarm

Articles 1 - 11 of 11

Full-Text Articles in Engineering

Fire Protection Engineering For Building A, Ai Choong Loh Jun 2023

Fire Protection Engineering For Building A, Ai Choong Loh

Fire Protection Engineering: Culminating Experience Project Reports

Building A is a 9-storey mixed used development in Singapore to be completed in 2028. Fire safety provisions of Building A shall be in accordance with Singapore Fire Code 2018.

The report has analyzed the fire safety provisions in the area of structural fire protection provision, means of escape provision, automatic water suppression system provision, automatic fire detection and alarm system provision, engineering smoke control system provision, flammability assessment as well as performance based assessment.

Generally, building A complied to the prescriptive requirements of automatic water suppression system provision, automatic fire detection and alarm system, structural fire provision and means …


Analysis Of Scramento State University Union, Zachary Schuler Jun 2023

Analysis Of Scramento State University Union, Zachary Schuler

Fire Protection Engineering: Culminating Experience Project Reports

Sacramento State Union is a centrally located building with a large occupant load during the school year. This building is a 239,000-square-foot three-story structure built originally back in 1975. This original building was constructed using waffle slab construction. Additions in 1996 and 2016 were built using steel beam and girder construction to meet the total square footage we have today. This mixed-use occupancy is not only a congregation point, but many events are held in this building as well.

In this analysis of the building, fire life safety systems are reviewed and determined if they not only meet the minimum …


A Fire Protection And Life Safety Analysis Of An Oupatient Healthcare System Building, Conrad Chandler Jun 2023

A Fire Protection And Life Safety Analysis Of An Oupatient Healthcare System Building, Conrad Chandler

Fire Protection Engineering: Culminating Experience Project Reports

The subject building of the report is an outpatient healthcare system building that is a two stories in height and 184,670 SF building. This building offers primary, specialty, and mental health outpatient care to patients throughout its state of location.

The facility is a mixed occupancy building with business as the primary occupancy, a surgery suite that classifies as an ambulatory health care occupancy, and assembly uses in the conference rooms, kitchen, and canteen. The Authority Having Jurisdiction (AHJ) has adopted the National Fire Codes (NFC) published by the National Fire Protection Association (NFPA), and throughout this report, the life …


Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger Jun 2023

Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger

Fire Protection Engineering: Culminating Experience Project Reports

Enclosed in this report is a comprehensive analysis of the fire protection and life safety components of the Illinois Department of Transportation (IDOT) District Six Headquarters building. The original building was constructed in 1972 and renovation operations were recently completed in 2022. The building is four stories in height with an aggregate floor area of approximately 69,300 square feet. The building functions as an office space for IDOT staff, therefore the majority of floor space is used as open office and private office space. The business spaces are supported by assembly spaces such as conference and break rooms on each …


Fire Protection And Life Safety Analysis Of A University Conference Center, Amanda Beck Larkin Jun 2022

Fire Protection And Life Safety Analysis Of A University Conference Center, Amanda Beck Larkin

Fire Protection Engineering: Culminating Experience Project Reports

This project report analyzes various aspects of fire protection and life safety design for a University Conference Center, for both prescriptive and performance-based designs. The University Conference Center is a ten-story, high-rise building comprised of various gathering spaces, ranging from small conference rooms to large assembly spaces with auditorium-style seating. The building has a large two-story podium with basement below, with a smaller floor plate, ten-story tower offset to one side.

In the prescriptive analysis, no deficiencies were noted in the water-based suppression or fire resistance analysis. The building construction type, height, area, number of stories, wall and structural ratings, …


Prescriptive And Performance-Based Analysis Of Colorado Liberal Arts College, Victor Wight Jun 2022

Prescriptive And Performance-Based Analysis Of Colorado Liberal Arts College, Victor Wight

Fire Protection Engineering: Culminating Experience Project Reports

This project consists of a prescriptive and performance-based analysis of an existing two-story college building. The building is located in downtown Colorado Springs, Colorado. Colorado Liberal Arts College is used for general education courses with the focus on creative fields such as dance, graphic design, and art. The building consists of classrooms, offices, an art gallery, dance studio, and a bookstore.

A prescriptive based design was completed using the code requirements laid out in the International Building Code (IBC) 2015 Edition and applicable National Fire Protection Association (NFPA) Codes. The prescriptive based analysis consisted of analyzing life safety and egress, …


Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal Jun 2022

Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal

Fire Protection Engineering: Culminating Experience Project Reports

This report contains an analysis of the life safety and fire protection features of a four-story apartment building in Maple Grove, Minnesota. The report is a part of the final project intended to meet the requirements for the Culminating Experience of the California Polytechnic Master of Science Fire Protection Engineering Program.

The apartment building chosen for the analysis is a mixed-use four-story wood-framed structure. The first floor of this structure includes office space for building management, a meeting space, and various electrical and mechanical spaces as well as apartments. There are exit stairways on each end of the structure extending …


The Spheres, Justin Milne Jun 2019

The Spheres, Justin Milne

Fire Protection Engineering: Culminating Experience Project Reports

The Spheres, an architectural masterpiece surrounded by a high-rise building complex, is in the heart of South Lake Union in Seattle, Washington. The Spheres building pushes limitations in building design on all levels. With hexecontahedron panels tessellated over the façade of its three spherical glass glaze greenhouse globes, the design affords futuristic personality, alongside energy efficacy while sustaining life within the building. While building innovations within The Spheres are certainly notable within all disciplines of Architecture, Engineering, and Construction, the contents of this report refer to fire protection engineering and code consulting elements.

In meeting The Spheres' required fire safety …


Centennial Station- Evaluation, Brandon Huffman Jun 2016

Centennial Station- Evaluation, Brandon Huffman

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this analysis is for completion of FPE 596 Culminating Experience in Fire Protection Engineering course in the Fire Protection Engineering Program at California Polytechnic State University. This analysis has been compiled using previous design courses evaluating the egress analysis, suppression design, alarm and detection design, smoke control system design, and structural fire protection. The context of the courses studied both prescriptive and performance based design approaches.

The building chosen for the analysis is Centennial Station located approximately 15 miles south of Denver, Colorado at 12154 East Easter Avenue, Englewood, CO 80112. The facility was designed specifically for …


Westside Christian High School, Michael Stewart Jun 2014

Westside Christian High School, Michael Stewart

Fire Protection Engineering: Culminating Experience Project Reports

The building I have chosen to use as the model for exemplifying the components of a wet fire suppression system is Westside Christian High School (WCHS). This building completed construction in January of 2014 and is located at: 8200 SW Pfaffle Street Tigard, Oregon 97223. The existing structure was previously owned and occupied by City Bible Church who will now lease space from the High school during and after construction. The renovations include the addition of space for music, art classes, fitness center, gym, science labs, and others. The renovations will also be widening existing rooms and hallways. The core …


Life Safety Report Xyz Office Building Denver Colorado, Keith Dix Jun 2013

Life Safety Report Xyz Office Building Denver Colorado, Keith Dix

Fire Protection Engineering: Culminating Experience Project Reports

This report is a Life Safety Analysis of the XYZ building in Colorado. It is a government contract facility and as such prefers that its real name and location not be utilized for this report. The building was assessed prescriptively using the 2009 International Building Code (IBC) and was found to be predominantly compliant with the code and the relevant referenced standards. The building was then assessed using a Performance Based Design in accordance with methodologies found and addressed in common fire protection literature. The Design Criteria chosen to determine tenability for the Required Safe Egress Time (RSET) were Carbon …