Safe Haptics-Enabled Patient-Robot Interaction For Robotic And Telerobotic Rehabilitation Of Neuromuscular Disorders: Control Design And Analysis, Seyed Farokh Atashzar Dec 2016

Safe Haptics-Enabled Patient-Robot Interaction For Robotic And Telerobotic Rehabilitation Of Neuromuscular Disorders: Control Design And Analysis, Seyed Farokh Atashzar

Electronic Thesis and Dissertation Repository

Motivation: Current statistics show that the population of seniors and the incidence rate of age-related neuromuscular disorders are rapidly increasing worldwide. Improving medical care is likely to increase the survival rate but will result in even more patients in need of Assistive, Rehabilitation and Assessment (ARA) services for extended periods which will place a significant burden on the world's healthcare systems. In many cases, the only alternative is limited and often delayed outpatient therapy. The situation will be worse for patients in remote areas. One potential solution is to develop technologies that provide efficient and safe means of in-hospital and …


Controlling And Processing Core For Wireless Implantable Telemetry System, Naeeme Modir Oct 2016

Controlling And Processing Core For Wireless Implantable Telemetry System, Naeeme Modir

Electronic Thesis and Dissertation Repository

Wireless implantable telemetry systems are suitable choices for monitoring various physiological parameters such as blood pressure and volume. These systems typically compose of an internal device implanted into a living body captures the physiological data and sends them to an external base station located outside of the body for further processing. The internal device usually consists of a sensor interface to convert the collected data to electrical signals; a digital core to digitize the analog signals, process them and prepare them for transmission; an RF front-end to transmit the data outside the body and to receive the required commands from …


Shape Memory Alloy Actuators And Sensors For Applications In Minimally Invasive Interventions, Amit Srivastava Sep 2016

Shape Memory Alloy Actuators And Sensors For Applications In Minimally Invasive Interventions, Amit Srivastava

Electronic Thesis and Dissertation Repository

Reduced access size in minimally invasive surgery and therapy (MIST) poses several restriction on the design of the dexterous robotic instruments. The instruments should be developed that are slender enough to pass through the small sized incisions and able to effectively operate in a compact workspace. Most existing robotic instruments are operated by big actuators, located outside the patient’s body, that transfer forces to the end effector via cables or magnetically controlled actuation mechanism. These instruments are certainly far from optimal in terms of their cost and the space they require in operating room. The lack of adequate sensing technologies …