Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Electronic Theses and Dissertations

Center for Orthopaedic Biomechanics

Articles 1 - 7 of 7

Full-Text Articles in Engineering

Laxity Of The Hip Capsule In Natural And Posteriorly Implanted Specimens, Luke Storer Jan 2019

Laxity Of The Hip Capsule In Natural And Posteriorly Implanted Specimens, Luke Storer

Electronic Theses and Dissertations

The hip capsule consists of ligament tissue that surrounds the hip joint, providing stability to ensure proper alignment, prevent dislocation, and facilitate proper joint function. The objective of this study was to characterize the torque-rotation response of the natural and posteriorly implanted hip capsule in healthy cadaveric specimens in multiple degrees-of-freedom (DOF) and under combined loading scenarios using the AMTI VIVO, a robotic joint simulator. The anterior portion of the hip capsule was stained with Methylene Blue and virtual extensometers were calculated by Digital Image Correlation (DIC) software for Finite Element Analysis (FEA) model validation. The range of motion (ROM) …


3d Bioprinting Hydrogel For Tissue Engineering An Ascending Aortic Scaffold, Benjamin Stewart Jan 2017

3d Bioprinting Hydrogel For Tissue Engineering An Ascending Aortic Scaffold, Benjamin Stewart

Electronic Theses and Dissertations

The gold standard in 2016 for thoracic aortic grafts is Dacron®, polyethylene terephthalate, due to the durability over time, the low immune response elicited and the propensity for endothelialization of the graft lumen over time. These synthetic grafts provide reliable materials that show remarkable long term patency. Despite the acceptable performance of Dacron® grafts, it is noted that autographs still outperform other types of vascular grafts when available due to recognition of the host's cells and adaptive mechanical properties of a living graft. 3-D bioprinting patient-specific scaffolds for tissue engineering (TE) brings the benefits of non-degrading synthetic …


Mechanical Effects Of Surgical Adhesives On Ascending Thoracic Aortic Aneurysm Replacement, Dong Qiu Jan 2017

Mechanical Effects Of Surgical Adhesives On Ascending Thoracic Aortic Aneurysm Replacement, Dong Qiu

Electronic Theses and Dissertations

Ascending thoracic aortic aneurysm (aTAA) is a potentially lethal disease which grows gradually over time and may lead to aortic dissection and rupture. Currently, aTAA surgical repair using Dacron graft is a well-established treatment. In addition, surgical adhesives are frequently used in the surgeries to seal the anastomotic site. This study aims to investigate mechanical effects of four commonly used surgical adhesives, namely BioGlue, CoSeal, Crosseal, and Tisseel, on the suture site using in-vitro digital image correlation (DIC) method and finite element (FE) simulations in an ovine model. In this study, first, mechanical properties of ovine ascending aorta were obtained …


Statistical Shape And Intensity Modeling Of The Shoulder, Irene Sintini Jan 2017

Statistical Shape And Intensity Modeling Of The Shoulder, Irene Sintini

Electronic Theses and Dissertations

Anatomical variability in the shoulder is inherently present and can influence healthy and pathologic biomechanics and ultimately clinical decision-making. Characterizing variation in bony morphology and material properties in the population can support treatment and specifically the design, via shape and sizing, of shoulder implants. Total Shoulder Arthroplasty (TSA) is the treatment of choice for glenohumeral osteoarthritis as well as bone fracture. Complications and poor outcomes in TSA are generally influenced by the inability of the implant to replicate the natural joint biomechanics and by the bone quality around the fixation features. For this reason, knowledge of bony morphology and mechanical …


Ex-Vivo Slaughterhouse Porcine Crystalloid-Perfused Beating Heart Via Langendorff Method, Rahiemin Talukder Jan 2016

Ex-Vivo Slaughterhouse Porcine Crystalloid-Perfused Beating Heart Via Langendorff Method, Rahiemin Talukder

Electronic Theses and Dissertations

The objective of this study was to resuscitate isolated beating porcine hearts obtained from slaughterhouse swine for a minimum of 1 hour with a crystalloid buffer reperfusion instead of blood via an extracorporeal Langendorff apparatus. The isolated beating heart functions outside of the body under simulated physiologic conditions. Live functional anatomy was controlled under benchtop experimental settings. Porcine hearts (26 total) were topically cooled with saline. 300mL of 25°C cardioplegia with 20KU Streptokinase was preflushed via aortic root. WIT was less than 5 minutes. 1L 4°C cardioplegia was flushed antegrade with aortic cannula (Group 1) or coronary catheterization (Group 2). …


The Neuromuscular Response To Spinal Manipulation: Quantifying The Effect Of Pain With Electromyography, Stuart James Currie Jan 2015

The Neuromuscular Response To Spinal Manipulation: Quantifying The Effect Of Pain With Electromyography, Stuart James Currie

Electronic Theses and Dissertations

Objective

To establish a methodology to quantify the neuromuscular response to spinal manipulation, develop a comprehensive date set including factors that affect the response, and compare the responses in both healthy participants and participants with acute and chronic low back pain.

Methods

Surface and indwelling electromyography at eight muscle locations were recorded during lumbar side-lying manipulations in 20 asymptomatic participants, 20 acute pain participants, and 20 chronic pain participants. Onset delay detection was optimized for signal detection failures and methodological comparisons were performed using a generalized linear model. The number of muscle responses and muscle activity onset delays in relation …


Electrohydrodynamic Atomization For Improved Macromolecular Drug Delivery, Michelle Zeles-Hahn Jan 2010

Electrohydrodynamic Atomization For Improved Macromolecular Drug Delivery, Michelle Zeles-Hahn

Electronic Theses and Dissertations

With advances in drug research, the use of biological therapeutics is becoming a reality. Unfortunately, methods for processing and delivering these fragile macromolecules often limit their therapeutic potential. For this dissertation, we explore the aerosolization of macromolecules by way of electrohydrodynamic atomization (EHDA) and how this method can be used to process and deliver therapeutics. EHDA employs a high voltage to break a column of liquid into drops. It was unknown if or how the residual charge left of the resulting droplets would affect lung cells. An in vitro experiment was conducted to spray aerosolized DNA, by way of EHDA, …