Automated Fault Detection In An Upflow Anaerobic Sludge Blanket Reactor: Comparisons Of Biogas Production And Physicochemical Quantities, Alexandra Maria Almeida Carvalho Pinto Dec 2001

Automated Fault Detection In An Upflow Anaerobic Sludge Blanket Reactor: Comparisons Of Biogas Production And Physicochemical Quantities, Alexandra Maria Almeida Carvalho Pinto

Doctoral Dissertations

A system capable of rapidly detecting toxic loads entering high-rate anaerobic reactors would greatly enhance their reliability, and could thereby increase their commercial acceptance. A high-rate anaerobic wastewater treatment process, called the failure-causing load detector (FCLD), consisting of a small (4-liter) upflow anaerobic sludge blanket (UASB) reactor having a short (10-min) hydraulic retention time (HRT), was used as a biosensor to rapidly detect potential problems with the influent wastewater. Sensors were used to monitor biogas production in the reactor, as well as pH, conductivity, and turbidity in the effluent from the reactor. The FCLD system was tested using the following …