Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- <p>Electrolytic reduction<br />Bromate -- Analysis<br />Reaction mechanisms (Chemistry) -- Design</p> (1)
- <p>Film boiling -- Mathematical models<br />Nucleate boiling<br />Heat -- Transmission</p> (1)
- <p>Film boiling<br />Heat-transfer media<br />Heat -- Transmission</p> (1)
- <p>Hydrocarbon reservoirs -- Mathematical models<br />Oil saturation in reservoirs<br />Oil fields -- Production methods</p> (1)
- <p>Hydrocarbon reservoirs -- Mathematical models<br />Residual stresses -- Mathematical models<br />Stress relaxation -- Mathematical models</p> (1)
Articles 1 - 7 of 7
Full-Text Articles in Engineering
Numerical Simulation Of Individual Wells In A Field Simulation Model, Ali Mohammed Akbar
Numerical Simulation Of Individual Wells In A Field Simulation Model, Ali Mohammed Akbar
Doctoral Dissertations
"Conventional numerical simulation of hydrocarbon reservoirs is inadequate for the prediction of bottom-hole pressures at production wells. This problem can be overcome by using a special mathematical model which combines individual well simulation with reservoir simulation. Severe computational instability is commonly encountered in the radial models due to the relatively small grid-blocks and high fluid velocities in the vicinity of the well bore. This instability is found to be more pronounced during depletion of the reservoir when the pressure near the well bore is below bubble-point pressure. A new technique is introduced here for saturation calculations in the critical region …
Convergence Of Material Balance In Mathematical Simulation Of Petroleum Reservoirs, Abdul Rashid Merchant
Convergence Of Material Balance In Mathematical Simulation Of Petroleum Reservoirs, Abdul Rashid Merchant
Doctoral Dissertations
One criterion for determining the precision of pressures calculated by a simulation model is the accuracy of the material balance. A high degree of precision in the calculated pressures is a necessary condition for elimination of error in prediction of fluid migration in the reservoir. However, this condition is not sufficient to guarantee accuracy of the simulation, since inaccuracies are introduced by truncation errors, machine round-off errors, and by the use of finite difference approximations to represent nonlinear partial differential equations.
A new procedure called Error Matrix Technique has been developed for reduction of material balance errors. This reduction is …
Electro-Reduction Of Bromate On Mercury, Jaw-Shin Chang
Electro-Reduction Of Bromate On Mercury, Jaw-Shin Chang
Doctoral Dissertations
"The electrochemical reduction of BrO⁻₃ was studied on a stationary Hg electrode in neutral and basic solutions containing K⁺, Na⁺, and L⁺. Coulombic efficiency studies showed Br⁻ to be the predominant reduction product. The steady state kinetic parameters include Tafel slopes of ca. -0.120 V, approximate first order activity dependences for both BrO⁻₃ and the accompanying cation, and no pH dependence. A reaction scheme is proposed which involves BrO⁻₃ "bridged" to the electrode by the accompanying cation. It is suggested that the "bridging" is a result of ion-pairing in the electrical double-layer"--Abstract, page 1.
Film Boiling Of Benzene, Freon 113, Freon 11, And Normal Pentane From Horizontal Surfaces At Atmospheric Pressure, Richard Stanley Kistler
Film Boiling Of Benzene, Freon 113, Freon 11, And Normal Pentane From Horizontal Surfaces At Atmospheric Pressure, Richard Stanley Kistler
Doctoral Dissertations
"A film boiling study was conducted with five different area flat plates at atmospheric pressure for benzene, Freon 113, Freon 11, and n-pentane. The heat transfer surface was horizontal for all tests.
The data were compared to the correlations commonly used for heat transfer. The common correlations were found to be in error for small surface sizes, but adequate for all fluids except benzene for the largest surface, a semi-empirical equation which correlates the available data as a function of surface diameter was derived and discussed"--Abstract, page iii.
An Application Of Residual Relaxation To Mathematical Simulation Of Petroleum Reservoirs, Grufron Achmad
An Application Of Residual Relaxation To Mathematical Simulation Of Petroleum Reservoirs, Grufron Achmad
Doctoral Dissertations
"Stability and convergence have long been primary concerns in the application of numerical techniques to the simulation of petroleum reservoir performance. An iterative method based on sequentially reducing the residual to zero at each grid point has been developed. It has been shown analytically that this residual relaxation method is stable, convergent, and consistent.
A three-phase areal model was developed to simulate a hypothetical homogeneous petroleum reservoir, and various computational methods were tested with this model. The residual relaxation method developed in this study (RELAX) was found to converge as rapidly as SIP, and much faster than either LSOR or …
Film Boiling Of Freon 113, Normal Pentane, Cyclopentane, And Benzene From Cylindrical Surfaces At Moderate Pressures, Gary Joseph Capone
Film Boiling Of Freon 113, Normal Pentane, Cyclopentane, And Benzene From Cylindrical Surfaces At Moderate Pressures, Gary Joseph Capone
Doctoral Dissertations
"An investigation of film boiling heat transfer in saturated pools of liquid Freon 113, Normal Pentane, Cyclopentane, and Benzene was made. The fluids were boiled from copper, cylindrical heat transfer surfaces, 3 inches long, and 0.55, 0.75, and 1.00 inch in diameter. The heat transfer elements were positioned horizontally in an autoclave and tested at moderate pressures of up to a pressure of 242.5 psia for Normal Pentane.
The experimental data are discussed and compared with known film boiling correlations. The known correlations were found to be inadequate in predicting heat transfer coefficients as a function of pressure, temperature difference …
Measurement Of Molecular Diffusivities Of Liquid Alkane Systems, James W. Moore
Measurement Of Molecular Diffusivities Of Liquid Alkane Systems, James W. Moore
Doctoral Dissertations
"An unsteady-state porous frit method of diffusion coefficient measurement, recently developed in this laboratory, was improved and expanded upon. The experimental technique has been refined and documented. The unsteady-state diffusion of an initially 0.5 N NaCl solution into pure water (effective diffusivity -1.480 x 10-5 cm2/sec) was employed as the calibration standard. An overall calibration precision of ±4% was obtained. Diffusion times of two hours or less were used for the non-aqueous diffusivity measurements. The validity of this measurement technique was confirmed by the agreement of the measured self-diffusion coefficient of n-heptane (25⁰C) with literature values.
A …