Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 1 of 1
Full-Text Articles in Engineering
Water Hammer Dissipation In Pneumatic Slug Tests, Don Degroot, David W. Ostendorf, Philip J. Dunaj
Water Hammer Dissipation In Pneumatic Slug Tests, Don Degroot, David W. Ostendorf, Philip J. Dunaj
Don DeGroot
We model and measure the dissipation of water hammer induced by well casing and water elasticity with rapid valve opening at the start of a pneumatic slug test. The higher-frequency water hammer can obscure slower, aquifer-controlled, underdamped oscillations of the rigid water column, so a quantitative description of the elastic motion improves the ability of a slug test to calibrate the aquifer permeability k. Internal friction attenuates the water hammer, subject to a known headspace pressure at the air/water interface and equilibrium pressure at the top of the well screen. An analytical elastic solution is presented and matched to an …