Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 8 of 8

Full-Text Articles in Engineering

City Of New Smyrna Beach Solar Feasibility Assessment, Florida Solar Energy Center, Charles Withers, Jr. Dec 2019

City Of New Smyrna Beach Solar Feasibility Assessment, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

At the request of the City of New Smyrna Beach, the Florida Solar Energy Center (FSEC) assessed rooftop solar and building energy efficiency improvement potential for 17 city-owned facilities. The intent has been to assist City leaders in identifying opportunities to reduce the City's overall electricity consumption and increase its use of renewable energy.

The FSEC team conducted Level 1 energy audit activities and site assessments including:

On-site assessment

  • Solar feasibility measurements and characterization including orientation, roof shading (adjacent structures, encroaching trees, etc.), available roof area, system output, annualized savings
  • HVAC characterization
  • Lighting survey
  • Occupancy density, schedule, thermostat settings

Post …


Environmental And Economic Implications Of Energy Efficiency In New Residential Buildings: A Multi-Criteria Selection Approach, Florida Solar Energy Center, Delia D'Agostino Sep 2019

Environmental And Economic Implications Of Energy Efficiency In New Residential Buildings: A Multi-Criteria Selection Approach, Florida Solar Energy Center, Delia D'Agostino

FSEC Energy Research Center®

The choice of the most appropriate technologies in buildings is often a challenge at the design stage, especially when many different criteria are taken into account. Consequently, the decision process relies often on one criterion only, such as costs or energy savings. We propose a multi-criteria approach based on multi-attribute utility theory to assess alternative energy efficiency measures, explicitly considering both environmental and economic criteria. We apply it to the design of a new residential building in Milan (Italy), with the aim to maximize CO2 emission savings related to electricity and gas consumption, and to minimize embodied energy and …


How Will Climate Alter Efficiency Objectives? Simulated Impact Of Using Recent Versus Historic European Weather Data For The Cost-Optimal Design Of Nearly Zero Energy Buildings (Nzebs), Florida Solar Energy Center, Delia D'Agostino Aug 2019

How Will Climate Alter Efficiency Objectives? Simulated Impact Of Using Recent Versus Historic European Weather Data For The Cost-Optimal Design Of Nearly Zero Energy Buildings (Nzebs), Florida Solar Energy Center, Delia D'Agostino

FSEC Energy Research Center®

Achieving "nearly zero energy buildings" (NZEB) has been established as a vital objective over the next decade within the European Union (EU) [1,2]. Previous work has shown that a series of very cost-effective thermal efficiency measures, equipment, appliance and renewable energy choices are available across climates to reach the NZEB objective. Resulting detailed energy and economic optimization findings have been obtained and published. One area that has just begun to be explored, however, is how selection of weather files and their application against coming climate change can influence outcomes from energy optimization procedures.

Presented at: CLIMA 2019, REHVA 13th HVAC …


Maximizing The Effectiveness Of Ductless Heat Pumps In Existing Homes By Demonstrating Integrated Controls: Measurement And Verification Plan, Florida Solar Energy Center, Eric Martin Jul 2019

Maximizing The Effectiveness Of Ductless Heat Pumps In Existing Homes By Demonstrating Integrated Controls: Measurement And Verification Plan, Florida Solar Energy Center, Eric Martin

FSEC Energy Research Center®

There is a trend for homeowners to install efficient ductless air-source heat pumps (ASHP) as a supplement to less efficient existing space conditioning systems, with most homeowners adding one unit in a central living area. Because of the potential for ASHPs to save energy by providing a large portion of the space conditioning, utilities have incentivized this strategy. However, post installation evaluations suggest ASHPs are not reaching their full potential because the existing heating system continues to operate more than necessary. This report describes a measurement and verifications strategy for a research project that aims to maximize savings from supplemental …


City Of New Smyrna Beach Solar Feasibility Assessment -- City Hall Annex, Florida Solar Energy Center, Charles Withers, Jr. Jul 2019

City Of New Smyrna Beach Solar Feasibility Assessment -- City Hall Annex, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

This review and solar assessment is organized by component with brief description of intended details, challenges and recommendations.

Building: City of New Smyrna Beach, City Hall Annex (Renovation of a portion of the Historic First Baptist Church of New Smyrna Beach) Year of Construction: 1920's[1] Building Use: Renovation will create spaces for City workers and a new City Council Chambers Conditioned area: 1st floor = 7856 ft2 2nd floor = 3,967 ft2 Total = 11,823 ft2[2]

[1] New Smyrna Beach Property Appraiser's website states 1920, historic marker states circa 1929. [2] New Smyrna …


Further Investigation Of Energy And Performance Impacts Of Whole-House Dehumidifier Duct Configurations, Florida Solar Energy Center, Charles Withers, Jr. Jun 2019

Further Investigation Of Energy And Performance Impacts Of Whole-House Dehumidifier Duct Configurations, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

This research project evaluated the energy impacts and dehumidification performance related to how ducted dehumidifiers (DHU) ducts were configured. Lab controlled testing over a variety of weather and latent loads evaluated five-different ducted DHU configurations as follows: Test 1 DHU air ducted from/to the central main body of building. Test 2 DHU air ducted from/to return side of central air conditioner (AC). Test 3 DHU air ducted from/to supply side of AC. Test 4 DHU air ducted from central main body and ducted to supply side of AC. Test 5 DHU air ducted from outdoors and indoors mixed before DHU …


Residential Attic Performance Comparison Research, Florida Solar Energy Center, Charles Withers, Jr. Jun 2019

Residential Attic Performance Comparison Research, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

This research project evaluated cooling energy and moisture-related impacts between conventional attic venting and sealed attic vents in a lab home located in central Florida. All tests had R30 insulation on the ceiling and the roof deck uninsulated. A total of four different test configurations were tested. The four tested configurations were: Attic Vented with Attic Ducts, Attic Vents Sealed with Attic Ducts, Attic Vented with Indoor Ducts, and Attic Vents Sealed with Indoor Ducts. On average the impact from sealing attic vents will increase annual cooling energy use in a Florida home between 5%-10%. For a 1620 square foot …


Evaluating Moisture Control Of Variable-Capacity Heat Pumps In Mechanically Ventilated, Low-Load Homes In Climate Zone 2a, Florida Solar Energy Center, Eric Martin Feb 2019

Evaluating Moisture Control Of Variable-Capacity Heat Pumps In Mechanically Ventilated, Low-Load Homes In Climate Zone 2a, Florida Solar Energy Center, Eric Martin

FSEC Energy Research Center®

The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. The …