Zawartość Węgla I Siarki W Pyle Pm2,5 I Pm10 W Powietrzu W Centrum Krakowa, Monika Dziugieł, Marek Bogacki, Robert Oleniacz, Marian Mazur Oct 2012

Zawartość Węgla I Siarki W Pyle Pm2,5 I Pm10 W Powietrzu W Centrum Krakowa, Monika Dziugieł, Marek Bogacki, Robert Oleniacz, Marian Mazur

Robert Oleniacz

This paper presents the results of the PM2.5 and PM10 mass concentration measurements in an urban air and results obtained from the additional chemical analysis concerning carbon and sulfur content of the collected dust samples. Dust samples were collected at the measuring point located on the roof of five-storey building at the AGH University of Science and Technology in Krakow, Poland (the center of the urban area of the city). In the scope of this study the relations between the carbon and sulfur content within the collected dust samples were determined in the function of the dust fraction content and …


Ocena Wielkości Emisji Do Powietrza Z Arcelormittal Poland S.A. Oddział W Krakowie W Odniesieniu Do Standardów Unii Europejskiej, Marian Mazur, Marek Bogacki, Robert Oleniacz Oct 2008

Ocena Wielkości Emisji Do Powietrza Z Arcelormittal Poland S.A. Oddział W Krakowie W Odniesieniu Do Standardów Unii Europejskiej, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The work presents emission factors of main air pollutants for installations of ArcelorMittal Poland S.A. Unit in Krakow (Poland) in comparison with analogous characteristic emissions for iron and steel industry in West Europe. In the comparison four installations (to coke, sinter, pig iron and steel production) were taken into consideration. The emission rates from ArcelorMittal Poland S.A. Unit in Krakow were estimated on the basis of the emission levels and production data from 2004, when took place the most significant production of liquid steel during last several years. As a result of the analysis, most the emission factors (with the …


Porównanie Poprzedniej I Aktualnej Metodyki Modelowania Rozprzestrzeniania Się Zanieczyszczeń W Powietrzu Opartej Na Modelu Smugi Gaussa, Robert Oleniacz, Marek Bogacki Jan 2004

Porównanie Poprzedniej I Aktualnej Metodyki Modelowania Rozprzestrzeniania Się Zanieczyszczeń W Powietrzu Opartej Na Modelu Smugi Gaussa, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Necessity of adaptation the Polish law in the field of the environment protection to the European Union law caused to adopt new criterions and methods of the air quality assessment. One of the methods of the air quality assessment is modeling of the substance levels in the air based on the calculation of the air pollutant dispersion in the atmosphere. Thus necessary changes also encompassed the basic methodology applied in our country for many years that had made possible calculation of the air pollution caused by existing and new emission sources. After some modifications the computation method was adopted as …


Referencyjna Metodyka Modelowania Poziomów Substancji W Powietrzu Na Tle Innych Modeli Obliczeniowych, Marek Bogacki, Robert Oleniacz Jan 2004

Referencyjna Metodyka Modelowania Poziomów Substancji W Powietrzu Na Tle Innych Modeli Obliczeniowych, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

In the paper some differences between various computational models applied to the atmospheric dispersion modeling were presented. These models each other were compared as regards the expanse-time scale of computation, description way of the wind field and the frame of reference for the air particle moves. Particular attention was paid to the Gauss plume model that was a base for a modeling method of the pollutant levels in the air accepting in Poland as the reference methodology. A general description, applications and limitations of this methodology were presented, as well data essential to the computation, way of the data preparing …


Likwidacja Strefy Ochronnej Wokół Huty Katowice W Dąbrowie Górniczej, Marian Mazur, Robert Oleniacz, Marek Bogacki Jun 2003

Likwidacja Strefy Ochronnej Wokół Huty Katowice W Dąbrowie Górniczej, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the history of the creation, management and liquidation of the protective zone around the Katowice Steelworks and Coke "Przyjaźń" (originally belonging to the "Katowice Steelworks") in Dąbrowa Górnicza (Poland). This zone was created in 1978 on the basis of the air quality impact assessment performed for the steelworks on the assumption steel production capacity of 9 million tons/year and planned production of coke at 3.3 million tons/year. These production volumes have never been achieved. In the 80's and 90's of the 20th century were conducted studies and calculations aimed to verify the nuisance of these plants on …


Likwidacja Strefy Ochronnej Huty Katowice I Zakładów Koksowniczych "Przyjaźń" W Dąbrowie Górniczej, Marian Mazur, Robert Oleniacz, Marek Bogacki Oct 2002

Likwidacja Strefy Ochronnej Huty Katowice I Zakładów Koksowniczych "Przyjaźń" W Dąbrowie Górniczej, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Legislation changes in Poland concerning the protective zones (created around industrial plants particularly harmful to the environment) were presented in the paper. Conditions connected with forming, developing and partial elimination of the protective zone existing around the "Katowice" steelworks and the coke plant Przyjaźń in Dąbrowa Górnicza (Poland) since 1978 were characterized as well.

English title: Elimination of the protective zone of the Katowice steelworks and the coke plant Przyjaźń in Dąbrowa Górnicza.


Ocena Zasięgu Istotnego Oddziaływania Emisji Zanieczyszczeń Z Huty Katowice Pod Kątem Likwidacji Strefy Ochronnej, Marian Mazur, Robert Oleniacz, Marek Bogacki Oct 2000

Ocena Zasięgu Istotnego Oddziaływania Emisji Zanieczyszczeń Z Huty Katowice Pod Kątem Likwidacji Strefy Ochronnej, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the results of air quality impact assessment of Katowice Steelworks in Dąbrowa Górnicza (Poland) in the protective zone. On the basis of calculations, it was found that in terms of air pollution there is a reasonable possibility of complete elimination of existing protective zone around these industrial plants.

English title: Assessment of the extent of significant effects of pollutant emissions from the "Katowice" Steelworks in terms of liquidation of the environmental protection zone.


Analiza Możliwości Likwidacji Stref Ochronnych Wokół Wybranych Zakładów Przemysłu Hutniczego I Koksochemicznego, Marian Mazur, Robert Oleniacz, Marek Bogacki Jun 2000

Analiza Możliwości Likwidacji Stref Ochronnych Wokół Wybranych Zakładów Przemysłu Hutniczego I Koksochemicznego, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Polish industrial plants with protective zones delimited in the past, have been faced with the necessity to liquidation of these zones before 2005. At the same time the plants must not cause any harmful influence over environment outside the area which they have title deed to. Determination of the current range of this impact is very important due to the high costs of a possible purchase of land exposed to the harmful effects. The study analyzes the possibility of verifying the course of borders two existing protective zones: around Katowice Steelworks and Coking Plant "Przyjaźń" in Dąbrowa Górnicza (the first …


Technologia Ciągłego Odlewania Stali I Jej Wpływ Na Ograniczenie Emisji Zanieczyszczeń Z Procesów Hutniczych, Marian Mazur, Marek Bogacki, Robert Oleniacz, Agnieszka Łopata, Anita Niedojadło Jun 2000

Technologia Ciągłego Odlewania Stali I Jej Wpływ Na Ograniczenie Emisji Zanieczyszczeń Z Procesów Hutniczych, Marian Mazur, Marek Bogacki, Robert Oleniacz, Agnieszka Łopata, Anita Niedojadło

Robert Oleniacz

The paper presents a comprehensive analysis of the impact of continuous casting of steel technology on air pollutant emissions in one of the Polish steelworks - Huta Katowice S.A. in Dąbrowa Górnicza. Emission sources occurring in the production process and the levels of pollutant emissions into the air were described. Implementation of continuous casting of steel brought significant changes in the production cycle in steelworks and caused an increase in the efficiency of manufacture of products. Calculated environmental effects showed a significant reduction of all pollutant emissions in the whole plant.

English title: Technology of continuous casting of steel and …


Ocena Zasięgu Oddziaływania Emisji Zanieczyszczeń Z Huty Katowice I Zk “Przyjaźń” W Dąbrowie Górniczej W Aspekcie Weryfikacji Wielkości Strefy Ochronnej, Marian Mazur, Marek Bogacki, Robert Oleniacz Sep 1998

Ocena Zasięgu Oddziaływania Emisji Zanieczyszczeń Z Huty Katowice I Zk “Przyjaźń” W Dąbrowie Górniczej W Aspekcie Weryfikacji Wielkości Strefy Ochronnej, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The paper presents the results of an analysis of current pollutant emissions from "Katowice" Steelworks and Coke Plant "Przyjaźń" in the Dąbrowa Górnicza (Poland) and calculations of spreading of these pollutants in the atmosphere. The research have shown that there is a reasonable possibility of reducing the existing protective zone around these plants, which should significantly reduce the costs incurred for the purchase of the land and management of the zone area.

English title: Assessment of the impact extent of pollutant emissions from "Katowice" Steelworks and Coke Plant "Przyjaźń" in the Dąbrowa Górnicza in terms of verification the size of …


Zastosowanie Modelu "Skrzynki" Do Oceny Poziomu Stężeń Zanieczyszczeń Komunikacyjnych W Przyziemnej Warstwie Atmosfery, Marek Bogacki, Marian Mazur, Robert Oleniacz Dec 1997

Zastosowanie Modelu "Skrzynki" Do Oceny Poziomu Stężeń Zanieczyszczeń Komunikacyjnych W Przyziemnej Warstwie Atmosfery, Marek Bogacki, Marian Mazur, Robert Oleniacz

Robert Oleniacz

Road transport is an essential source of nitrogen oxides (NOx), carbon monoxide (CO) and reactive hydrocarbons (RHC) emissions to atmosphere. Quantity and chemical constitution of emitted substances and meteorological conditions determine the level of ozon (O3) concentration forming as a result of photochemical reactions. The method presented in the paper consists in designation of quantity and chemical constitution of substances emitted from mo-bile sources and special mathematical modeling of physical and chemical transformations that take place in the lowest atmospheric layer.

English title: The use of box model to estimate the size of traffic pollutant concentrations in the lowest atmospheric …


Wdrażanie Monitoringu Zanieczyszczeń Powietrza Atmosferycznego W Kielcach, Marian Mazur, Robert Oleniacz, Marek Bogacki Dec 1996

Wdrażanie Monitoringu Zanieczyszczeń Powietrza Atmosferycznego W Kielcach, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Assumptions for regional environmental monitoring in the province of Kielce were developed as early as 1992. Since the beginning of particular attention were monitoring the air. The article presents the next step in the implementation of this monitoring, associated with verification of the location and the measuring range of points to measure the concentrations of air pollutants in Kielce. As a result of analysis and calculations, it was found that the original location is not always correct and does not reflect the spatial differentiation of pollutant concentrations. The proposed changes in the position of monitoring points or measurement methods were …


Zastosowanie Metody Obliczeniowo-Pomiarowej Do Oceny Stanu Zanieczyszczenia Powietrza W Nowym Sączu, Marian Mazur, Marek Bogacki, Robert Oleniacz Dec 1996

Zastosowanie Metody Obliczeniowo-Pomiarowej Do Oceny Stanu Zanieczyszczenia Powietrza W Nowym Sączu, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

Assessment of the state of air pollution in the urban area is a difficult and complex task. Depending on the method of assessment the procedure requires a comprehensive research and calculations of air emissions from all sources occurring in the area and the use of atmospheric dispersion models or large-scale implementation of direct measurements of air pollutant concentrations. Both of these methods may also be applied simultaneously to their mutual verification.

The article presents the results of such a comprehensive assessment of air pollution on the example of the city of Nowy Sacz (Poland). This involved determining the emissions of …


Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz Sep 1996

Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The paper presents the results of a comprehensive assessment of air pollution in the city of Nowy Sącz (Poland). This involved determining the emissions of selected pollutants from various sources with their percentages of the total emission and immission on the area under consideration. As a result of measurement of concentrations of particulate matter and benzo(a)pyrene in several parts of the city were verified results of theoretical calculations and determined the size of the inflow of pollutants from outside the area in question.

English title: A comprehensive assessment of air quality in Nowy Sącz using computational and measuring methods.


Ocena I Weryfikacja Lokalizacji Stanowisk Pomiarowych Imisji Zanieczyszczeń Powietrza W Województwie Kieleckim, Marian Mazur, Robert Oleniacz Jun 1995

Ocena I Weryfikacja Lokalizacji Stanowisk Pomiarowych Imisji Zanieczyszczeń Powietrza W Województwie Kieleckim, Marian Mazur, Robert Oleniacz

Robert Oleniacz

The paper presents the implementation of air pollution monitoring in the province of Kielce (Poland), associated with verification of the location and the measuring range of points to measure the concentrations of air pollutants. For this purpose were used calculations of the pollutants dispersion and statistical analysis of measurement results obtained on existing measuring stations. In the statistical calculations were used analysis of variance homogeneity, based on Cochran, Bartlett and Hartley tests. As a result of analysis and calculations, it was found that the original location is not always correct and does not reflect the spatial differentiation of pollutant concentrations. …