Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 28 of 28

Full-Text Articles in Engineering

Obliczenia Rozprzestrzeniania Się Pyłu Drobnego W Powietrzu Atmosferycznym Z Wykorzystaniem Dyfuzyjnych Modeli Gaussa, Robert Oleniacz, Mateusz Rzeszutek Jun 2015

Obliczenia Rozprzestrzeniania Się Pyłu Drobnego W Powietrzu Atmosferycznym Z Wykorzystaniem Dyfuzyjnych Modeli Gaussa, Robert Oleniacz, Mateusz Rzeszutek

Robert Oleniacz

The chapter presents a comparison of results of modelling concentrations of fine dust (suspended dust PM10) in the air with the use of two diffusion models: the Gaussian plume model (used commonly in Poland), and the Gaussian puff model CALPUFF (used significantly less frequently). It indicates discrepancies in obtained results of calculations for point emitters taking into consideration three dimensional options (with the following heights: 20, 40 and 60 m and diameters of respectively: 1.0, 1.5 and 2.0 m). For particular variants, errors were visualised, resulting from use of the simple Gaussian plume model in place of the advanced CALPUFF …


Zastosowanie Systemu Modeli Calmet/Calpuff O Wysokiej Rozdzielczości Do Oceny Wpływu Na Jakość Powietrza Spalarni Odpadów Komunalnych W Krakowie, Mateusz Rzeszutek, Robert Oleniacz Mar 2015

Zastosowanie Systemu Modeli Calmet/Calpuff O Wysokiej Rozdzielczości Do Oceny Wpływu Na Jakość Powietrza Spalarni Odpadów Komunalnych W Krakowie, Mateusz Rzeszutek, Robert Oleniacz

Robert Oleniacz

In this paper there was presented a comprehensive assessment of the impact on air for the Municipal Solid Waste Incineration (MSWI) plant in Krakow with the planned start of operation by the end of 2015. Construction of the plant started in autumn 2013 in the district of Nowa Huta in Krakow. Modeling of the spread of pollutants in ambient air was conducted using an advanced multi-layer cloud CALPUFF Gaussian model, whose algorithms include, among other things, diversity of terrain. Spatial data of land area in the admitted computational domain are obtained from digital terrain model Shuttle Radar Topography Mission (SRTM3) …


Ocena Wpływu Na Jakość Powietrza Procesu Przygotowania Obszaru Wiertni Przy Poszukiwaniach Gazu Z Łupków, Marek Bogacki, Robert Oleniacz, Monika Janicka Oct 2014

Ocena Wpływu Na Jakość Powietrza Procesu Przygotowania Obszaru Wiertni Przy Poszukiwaniach Gazu Z Łupków, Marek Bogacki, Robert Oleniacz, Monika Janicka

Robert Oleniacz

This chapter presents the model calculation results of the level of concentration of air pollutants emitted during works related to the preparation of the drilling pad for the shale gas exploration. The most significant emission sources located in the drilling pad, including rig access roads, paved and unpaved, were analyzed. The emission field was defined by the parameterization of various sources/processes, taking into account the technical, technological, organizational and environmental conditions. The calculations of the pollutants dispersion in the air were carried out using the Gaussian reference model. The results of numerical calculations showed that the only substance likely to …


Ocena Wpływu Rozdzielczości Siatki Obliczeniowej Na Wyniki Modelowania Rozprzestrzeniania Się Zanieczyszczeń W Powietrzu, Mateusz Rzeszutek, Robert Oleniacz, Marian Mazur Oct 2014

Ocena Wpływu Rozdzielczości Siatki Obliczeniowej Na Wyniki Modelowania Rozprzestrzeniania Się Zanieczyszczeń W Powietrzu, Mateusz Rzeszutek, Robert Oleniacz, Marian Mazur

Robert Oleniacz

In this study are presented the results of the assessment of the impact of grid resolution on the results of computational modeling of the dispersion of air pollutants. Calculations were performed using Gaussian, non-stationary puff model CALPUFF. Four different grids resolution were analyzed. Networks were established on the basis of SRTM3 terrain and land cover classes of CLC, 2006. Analysis of results of spatial distribution of concentrations of air pollutants obtained in a regular computing grid was performed using statistical indicators recommended by the U.S. EPA. The study shows the applicability of particular computational grids in the system modeling transport …


Determination Of Optimal Spatial Databases For The Area Of Poland To The Calculation Of Air Pollutant Dispersion Using The Calmet/Calpuff Model, Robert Oleniacz, Mateusz Rzeszutek Jun 2014

Determination Of Optimal Spatial Databases For The Area Of Poland To The Calculation Of Air Pollutant Dispersion Using The Calmet/Calpuff Model, Robert Oleniacz, Mateusz Rzeszutek

Robert Oleniacz

The paper presents a methodology for the preparation of three-dimensional spatial data and land use data for the purpose of modeling pollutant dispersion in the ambient air using a group of geophysical preprocessors of the CALMET/CALPUFF modeling system and the GIS software. Some space information data sources available to Poland were specified and their characteristics and availability were discussed. Particular attention was turned to the SRTM3 and GTOPO30 elevation data as well as the CLC2006 and GLCC land use data, for the preparation of computational grids of different resolutions. Groups of programs which can be used in order to form …


Ocena Wpływu Nowo Budowanej Spalarni Odpadów Komunalnych W Krakowie Na Jakość Powietrza Z Wykorzystaniem Modelu Calmet/Calpuff, Mateusz Rzeszutek, Robert Oleniacz Jun 2014

Ocena Wpływu Nowo Budowanej Spalarni Odpadów Komunalnych W Krakowie Na Jakość Powietrza Z Wykorzystaniem Modelu Calmet/Calpuff, Mateusz Rzeszutek, Robert Oleniacz

Robert Oleniacz

The chapter presents the results of the evaluation the impact on air quality for the newly built Municipal Solid Waste Thermal Treatment Plant in Krakow (Poland) whose construction started in autumn 2013. Air pollution impact assessment was performed for air emissions adopted at the levels of emission limit values applicable for waste incineration. Modeling of air pollutant dispersion was carried out using the system of CALMET/CALPUFF models. For this purpose, the terrain elevation data from Shuttle Radar Topography Mission (SRTM3) and data of land use from Corine Land Cover 2006 (CLC 2006) were adopted with a resolution of about 100 …


Niekontrolowane Spalanie Odpadów I Pozostałości Roślinnych Na Terenach Wiejskich – Przykład Inwentaryzacji Źródeł Emisji I Oceny Wpływu Na Jakość Powietrza, Robert Oleniacz, Barbara Bacik, Marcelina Spiszak Jun 2014

Niekontrolowane Spalanie Odpadów I Pozostałości Roślinnych Na Terenach Wiejskich – Przykład Inwentaryzacji Źródeł Emisji I Oceny Wpływu Na Jakość Powietrza, Robert Oleniacz, Barbara Bacik, Marcelina Spiszak

Robert Oleniacz

The most troublesome air pollutant emissions that occur in rural areas are associated with the operation of domestic furnaces (mainly during the heating season) and the processes of open burning of plant residues (mainly outside the heating season). The paper presents an example of emission inventory for this type of sources in two submontane villages of Małopolska Voivodeship (Poland) based on the results of the questionnaire survey and an attempt to assess the impact on air quality of these sources, including the potential uncontrolled burning of waste.The conducted questionnaire survey showed the use to home heating mainly solid fuels (first …


Wykorzystanie Atmosferycznego Modelu Dyspersji Calpuff Do Oceny Oddziaływania Na Jakość Powietrza Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych W Krakowie, Mateusz Rzeszutek, Robert Oleniacz Apr 2014

Wykorzystanie Atmosferycznego Modelu Dyspersji Calpuff Do Oceny Oddziaływania Na Jakość Powietrza Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych W Krakowie, Mateusz Rzeszutek, Robert Oleniacz

Robert Oleniacz

The aim of this study was to determine the influence of the planned Municipal Waste Thermal Treatment Plant in Krakow on air pollution. Air quality impact assessment was based on the current state of the legal formalities (including emission limit values for waste incineration plants) and the results of the air pollutant atmospheric dispersion modeling for one month period. In this study to calculate of air pollutant dispersion was used model system CALMET/CALPUFF. Using the CALMET model variables in time and space weather condition were calculated. CALPUFF model were performed to computing of propagation of air pollution. Analysis of the …


Zawartość Węgla I Siarki W Pyle Pm2,5 I Pm10 W Powietrzu W Centrum Krakowa, Monika Dziugieł, Marek Bogacki, Robert Oleniacz, Marian Mazur Oct 2012

Zawartość Węgla I Siarki W Pyle Pm2,5 I Pm10 W Powietrzu W Centrum Krakowa, Monika Dziugieł, Marek Bogacki, Robert Oleniacz, Marian Mazur

Robert Oleniacz

This paper presents the results of the PM2.5 and PM10 mass concentration measurements in an urban air and results obtained from the additional chemical analysis concerning carbon and sulfur content of the collected dust samples. Dust samples were collected at the measuring point located on the roof of five-storey building at the AGH University of Science and Technology in Krakow, Poland (the center of the urban area of the city). In the scope of this study the relations between the carbon and sulfur content within the collected dust samples were determined in the function of the dust fraction content and …


Study Of Nano Structure Mn/Alumina Catalyst Deactivation Through Catalytic Oxidation Of O-Vocs, Hosein Afshary May 2010

Study Of Nano Structure Mn/Alumina Catalyst Deactivation Through Catalytic Oxidation Of O-Vocs, Hosein Afshary

Hosein Afshary

the deactivation and selectivity behavior of nanostructure Mn/γ-Al2O3 catalyst in catalytic oxidation of an O-VOC (isopropanol) was studied. The polluted air was simulated and the catalyst was tested in the course of 50-h time-on-stream. Characterization of fresh and used catalysts was done using FT-IR, XRD, SEM and EDS methods. Comparing the testing results of this catalyst and that of the industrial Pt/Al2O3 catalyst showed that prepared catalyst can be suitable for substitution with the expensive pt/Al2O3 catalyst in environmental applications.


Ocena Wpływu Arcelormittal Poland S.A. Oddział W Krakowie Na Jakość Powietrza, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski Oct 2008

Ocena Wpływu Arcelormittal Poland S.A. Oddział W Krakowie Na Jakość Powietrza, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski

Robert Oleniacz

The work presents selected results of atmospheric dispersion modeling and air quality impact assessment for pollutant emissions from installations of ArcelorMittal Poland S.A. Unit in Krakow (Poland). The assessment was carried out for the most unfavourable emission variant probable to take place in the period 2007-2016. In the calculations were taken into consideration typical for steelworks particle matter pollutants (total dust, heavy metals, tar substances and PAHs including benzo-a-piren) and gaseous substances (SO2, NO2, CO, HC, HCl, HF, NH3, HCN, H2S, CS2, H2SO4, BTX, phenol and pyridine). As the result of estimations, carried out according to the Polish reference method …


Wpływ Dużej Spalarni Odpadów Przemysłowych I Niebezpiecznych Na Jakość Powietrza, Robert Oleniacz, Lidia Rusztowicz Jan 2007

Wpływ Dużej Spalarni Odpadów Przemysłowych I Niebezpiecznych Na Jakość Powietrza, Robert Oleniacz, Lidia Rusztowicz

Robert Oleniacz

Waste incineration causes unavoidable pollutant emissions to atmosphere and thus negative impact on air quality, but scale of the influence is often exaggerated. In the paper computation results of the atmospheric dispersion of pollutants were presented for one of the largest industrial and hazardous waste incineration plant existing in Poland (processing capacity: 3 ton per hour). These results confirm the fact that the incinerator meets the requirements of best available techniques (BAT) for the waste incineration and its impact on air quality is relatively small. This effect is caused mainly by proper operation of the rotary kiln incinerator, high efficiency …


Analiza Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch Jan 2007

Analiza Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch

Robert Oleniacz

Construction of the Municipal Solid Waste Incineration (MSWI) plant is considered optimal in the Programme of Management of Solid Waste in Krakow as well as in proposed scenarios of Municipal Waste Management. Evaluation of impact of the incineration plant with a capacity of 255000 tons per year on air quality in Krakow is presented in this work. The evaluation is based on assumption that air pollutant emissions from the incinerator will be at the highest allowed level resulting from emission limit values for waste incineration plants with operation time each of two planned lines 7500 hours per year. Calculation results …


Ocena Oddziaływania Na Środowisko Instalacji Spalania Odpadów – Wybrane Problemy, Robert Oleniacz Oct 2005

Ocena Oddziaływania Na Środowisko Instalacji Spalania Odpadów – Wybrane Problemy, Robert Oleniacz

Robert Oleniacz

The paper presents some problems related to the environmental impact of waste incineration plants with particular emphasis on the impact on air quality and the assessment of this impact carried out for newly built incinerators. Methodology for the calculation of emissions for new plants based on emission standards was proposed. It has been shown that waste incineration plants complying with emission limit values to a negligible extent affect the air quality, especially in the case of units with small capacity.

In the case of polychlorinated dibenzo-p-dioxins and dibenzofurans, due to lack of permissible levels in the air, it was found …


Ocena Oddziaływania Mittal Steel Poland S.A. Oddział W Krakowie Na Jakość Powietrza W Aspekcie Likwidacji Strefy Ochronnej, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski Oct 2005

Ocena Oddziaływania Mittal Steel Poland S.A. Oddział W Krakowie Na Jakość Powietrza W Aspekcie Likwidacji Strefy Ochronnej, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski

Robert Oleniacz

The paper presents results of the air quality impact assessment for Mittal Steel Poland S.A. unit in Krakow (Poland). The assessment included all emission sources working in the unit in 2003 as well as emission sources belonging to companies separated from the steelworks in the past. A special attention was taken to comply of air quality standards in area of the protective zone in connection with their planned liquidation by the end of 2005 (the requirement of the new environmental law).

English title: Evaluation of impact of Mittal Steel Poland S.A. unit in Krakow on air quality in connection with …


Zmiany W Metodyce Modelowania Rozprzestrzeniania Się Zanieczyszczeń W Powietrzu Opartej Na Modelu Gaussa, Robert Oleniacz, Marek Bogacki Oct 2003

Zmiany W Metodyce Modelowania Rozprzestrzeniania Się Zanieczyszczeń W Powietrzu Opartej Na Modelu Gaussa, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the changes that have occurred in December 2002 in the Polish reference modeling methodology (based on the stationary Gaussian atmospheric dispersion model) used for the air quality impact assessment in Poland since the 60s of the 20th century. Discusses the changes that have occurred in the preparation of data for the simulation, the procedure used in shortened and full range of calculation, the algorithms of initial computations and the results of calculations.

English Title: Changes in the methodology of modeling the pollutant dispersion in the air based on the Gaussian model.


Weryfikacja Emisji Pyłowej Z Huty Katowice I Zasięgu Jej Oddziaływania, Marian Mazur, Robert Oleniacz, Marek Bogacki, Agnieszka Łopata Jun 2002

Weryfikacja Emisji Pyłowej Z Huty Katowice I Zasięgu Jej Oddziaływania, Marian Mazur, Robert Oleniacz, Marek Bogacki, Agnieszka Łopata

Robert Oleniacz

Preliminary analysis of the results of atmospheric dispersion modeling for dust emission from the Katowice Steelworks (Poland) showed necessity of verification the particulate matter, lead and cadmium emission from the plant. The verification was limited to the substance emission sources influencing air pollution to the largest extent. Both scale of dust emission and its granulometric and chemical composition were re-evaluated. Further calculations of the air propagation for the pollutants were carried out and calculation results were compared with direct measurements. Thus the Katowice Steelworks impact on air quality and the level of total dust, lead and cadmium ground deposition was …


Ocena Udziału Huty Katowice W Poziomie Opadu Pyłu, Ołowiu I Kadmu Na Powierzchnię Terenu Wokół Zakładu, Marian Mazur, Robert Oleniacz, Marek Bogacki Sep 2001

Ocena Udziału Huty Katowice W Poziomie Opadu Pyłu, Ołowiu I Kadmu Na Powierzchnię Terenu Wokół Zakładu, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the results of modeling of deposition on the land surface of dust, lead and cadmium emitted from the "Katowice" Steelworks. The calculations were carried out in the vicinity of the location of the dust deposition measuring points existing around the plant. Computational data were compared with the results obtained from direct measurements for the same calendar year. The responsibility of this plant in shaping the level of dust and heavy metal deposition in the region of the protective zone was determined.

English title: Participation of the "Katowice" Steelworks in the level of dust, lead and cadmium deposition …


Ocena Zasięgu Istotnego Oddziaływania Emisji Zanieczyszczeń Z Huty Katowice Pod Kątem Likwidacji Strefy Ochronnej, Marian Mazur, Robert Oleniacz, Marek Bogacki Oct 2000

Ocena Zasięgu Istotnego Oddziaływania Emisji Zanieczyszczeń Z Huty Katowice Pod Kątem Likwidacji Strefy Ochronnej, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the results of air quality impact assessment of Katowice Steelworks in Dąbrowa Górnicza (Poland) in the protective zone. On the basis of calculations, it was found that in terms of air pollution there is a reasonable possibility of complete elimination of existing protective zone around these industrial plants.

English title: Assessment of the extent of significant effects of pollutant emissions from the "Katowice" Steelworks in terms of liquidation of the environmental protection zone.


Analiza Możliwości Likwidacji Stref Ochronnych Wokół Wybranych Zakładów Przemysłu Hutniczego I Koksochemicznego, Marian Mazur, Robert Oleniacz, Marek Bogacki Jun 2000

Analiza Możliwości Likwidacji Stref Ochronnych Wokół Wybranych Zakładów Przemysłu Hutniczego I Koksochemicznego, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Polish industrial plants with protective zones delimited in the past, have been faced with the necessity to liquidation of these zones before 2005. At the same time the plants must not cause any harmful influence over environment outside the area which they have title deed to. Determination of the current range of this impact is very important due to the high costs of a possible purchase of land exposed to the harmful effects. The study analyzes the possibility of verifying the course of borders two existing protective zones: around Katowice Steelworks and Coking Plant "Przyjaźń" in Dąbrowa Górnicza (the first …


Ocena Zasięgu Oddziaływania Emisji Zanieczyszczeń Z Huty Katowice I Zk “Przyjaźń” W Dąbrowie Górniczej W Aspekcie Weryfikacji Wielkości Strefy Ochronnej, Marian Mazur, Marek Bogacki, Robert Oleniacz Sep 1998

Ocena Zasięgu Oddziaływania Emisji Zanieczyszczeń Z Huty Katowice I Zk “Przyjaźń” W Dąbrowie Górniczej W Aspekcie Weryfikacji Wielkości Strefy Ochronnej, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The paper presents the results of an analysis of current pollutant emissions from "Katowice" Steelworks and Coke Plant "Przyjaźń" in the Dąbrowa Górnicza (Poland) and calculations of spreading of these pollutants in the atmosphere. The research have shown that there is a reasonable possibility of reducing the existing protective zone around these plants, which should significantly reduce the costs incurred for the purchase of the land and management of the zone area.

English title: Assessment of the impact extent of pollutant emissions from "Katowice" Steelworks and Coke Plant "Przyjaźń" in the Dąbrowa Górnicza in terms of verification the size of …


Koncepcja Monitoringu Zanieczyszczeń Powietrza Wokół Elektrowni “Jaworzno Iii” Mobilną Stacją Pomiarową, Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz Jun 1997

Koncepcja Monitoringu Zanieczyszczeń Powietrza Wokół Elektrowni “Jaworzno Iii” Mobilną Stacją Pomiarową, Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz

Robert Oleniacz

The paper presents the concept of air pollution monitoring around the Power Plant "Jaworzno III" (Poland) with the use of the mobile station. Aim of the new monitoring system is to provide information about the current state of air pollution and to enable an assessment of the environmental implications of the use of low-emission burners, run the installation of flue gas desulphurisation and changes in the way of releasing flue gases into the atmosphere. Due to economic, technical and practical the monitoring system was based on a single mobile station. Measurements will be carried out in a random scheme at …


Wdrażanie Monitoringu Zanieczyszczeń Powietrza Atmosferycznego W Kielcach, Marian Mazur, Robert Oleniacz, Marek Bogacki Dec 1996

Wdrażanie Monitoringu Zanieczyszczeń Powietrza Atmosferycznego W Kielcach, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Assumptions for regional environmental monitoring in the province of Kielce were developed as early as 1992. Since the beginning of particular attention were monitoring the air. The article presents the next step in the implementation of this monitoring, associated with verification of the location and the measuring range of points to measure the concentrations of air pollutants in Kielce. As a result of analysis and calculations, it was found that the original location is not always correct and does not reflect the spatial differentiation of pollutant concentrations. The proposed changes in the position of monitoring points or measurement methods were …


Zastosowanie Metody Obliczeniowo-Pomiarowej Do Oceny Stanu Zanieczyszczenia Powietrza W Nowym Sączu, Marian Mazur, Marek Bogacki, Robert Oleniacz Dec 1996

Zastosowanie Metody Obliczeniowo-Pomiarowej Do Oceny Stanu Zanieczyszczenia Powietrza W Nowym Sączu, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

Assessment of the state of air pollution in the urban area is a difficult and complex task. Depending on the method of assessment the procedure requires a comprehensive research and calculations of air emissions from all sources occurring in the area and the use of atmospheric dispersion models or large-scale implementation of direct measurements of air pollutant concentrations. Both of these methods may also be applied simultaneously to their mutual verification.

The article presents the results of such a comprehensive assessment of air pollution on the example of the city of Nowy Sacz (Poland). This involved determining the emissions of …


Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz Sep 1996

Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The paper presents the results of a comprehensive assessment of air pollution in the city of Nowy Sącz (Poland). This involved determining the emissions of selected pollutants from various sources with their percentages of the total emission and immission on the area under consideration. As a result of measurement of concentrations of particulate matter and benzo(a)pyrene in several parts of the city were verified results of theoretical calculations and determined the size of the inflow of pollutants from outside the area in question.

English title: A comprehensive assessment of air quality in Nowy Sącz using computational and measuring methods.


Zanieczyszczenie Powietrza Kotliny Sądeckiej Przez Przemysł Elektrodowy, Marian Mazur, Marek Bogacki, Robert Oleniacz Feb 1996

Zanieczyszczenie Powietrza Kotliny Sądeckiej Przez Przemysł Elektrodowy, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The article evaluates the impact of electrode industry (production of carbon and graphite electrodes in the plant Polgraph SA) on air quality in the Kotlina Sądecka valley and the city Nowy Sącz (Poland). The work presents completed so far environmental investments and the level of emissions of selected air pollutants characteristic of the analyzed facility, including PAHs emissions. Based on the modeling of the dispersion of pollutants in ambient air was determined the levels of pollutant concentrations in the air and location of most affected areas. The calculation results were compared with the results of direct measurements. Particular attention was …


Zastosowanie Modelowania Matematycznego Do Oceny Zanieczyszczenia Powietrza Powodowanego Przez Motoryzację, Marian Mazur, Robert Oleniacz, Bożena Biernat-Oleniacz Dec 1995

Zastosowanie Modelowania Matematycznego Do Oceny Zanieczyszczenia Powietrza Powodowanego Przez Motoryzację, Marian Mazur, Robert Oleniacz, Bożena Biernat-Oleniacz

Robert Oleniacz

The paper presents the results of an inventory of sources of air emissions from the city of Nowy Sacz (Poland) with regard to pollutant emissions from road transport, industrial processes, combustion plants and low-emissions from household furnaces. Particular attention has been devoted to assessing the impact of traffic on air quality in the city. Specified share of emissions from motor vehicles in the state of air pollution in the city center and its outskirts using the method of the atmospheric dispersion modeling.

English title: The use of mathematical modeling to assess air pollution caused by road transport.


Ocena I Weryfikacja Lokalizacji Stanowisk Pomiarowych Imisji Zanieczyszczeń Powietrza W Województwie Kieleckim, Marian Mazur, Robert Oleniacz Jun 1995

Ocena I Weryfikacja Lokalizacji Stanowisk Pomiarowych Imisji Zanieczyszczeń Powietrza W Województwie Kieleckim, Marian Mazur, Robert Oleniacz

Robert Oleniacz

The paper presents the implementation of air pollution monitoring in the province of Kielce (Poland), associated with verification of the location and the measuring range of points to measure the concentrations of air pollutants. For this purpose were used calculations of the pollutants dispersion and statistical analysis of measurement results obtained on existing measuring stations. In the statistical calculations were used analysis of variance homogeneity, based on Cochran, Bartlett and Hartley tests. As a result of analysis and calculations, it was found that the original location is not always correct and does not reflect the spatial differentiation of pollutant concentrations. …