Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

SelectedWorks

Physical Sciences and Mathematics

Air Quality Assessment and Management

Articles 1 - 19 of 19

Full-Text Articles in Engineering

Niekontrolowane Spalanie Odpadów I Pozostałości Roślinnych Na Terenach Wiejskich – Przykład Inwentaryzacji Źródeł Emisji I Oceny Wpływu Na Jakość Powietrza, Robert Oleniacz, Barbara Bacik, Marcelina Spiszak Jun 2014

Niekontrolowane Spalanie Odpadów I Pozostałości Roślinnych Na Terenach Wiejskich – Przykład Inwentaryzacji Źródeł Emisji I Oceny Wpływu Na Jakość Powietrza, Robert Oleniacz, Barbara Bacik, Marcelina Spiszak

Robert Oleniacz

The most troublesome air pollutant emissions that occur in rural areas are associated with the operation of domestic furnaces (mainly during the heating season) and the processes of open burning of plant residues (mainly outside the heating season). The paper presents an example of emission inventory for this type of sources in two submontane villages of Małopolska Voivodeship (Poland) based on the results of the questionnaire survey and an attempt to assess the impact on air quality of these sources, including the potential uncontrolled burning of waste.The conducted questionnaire survey showed the use to home heating mainly solid fuels (first …


Zawartość Węgla I Siarki W Pyle Pm2,5 I Pm10 W Powietrzu W Centrum Krakowa, Monika Dziugieł, Marek Bogacki, Robert Oleniacz, Marian Mazur Oct 2012

Zawartość Węgla I Siarki W Pyle Pm2,5 I Pm10 W Powietrzu W Centrum Krakowa, Monika Dziugieł, Marek Bogacki, Robert Oleniacz, Marian Mazur

Robert Oleniacz

This paper presents the results of the PM2.5 and PM10 mass concentration measurements in an urban air and results obtained from the additional chemical analysis concerning carbon and sulfur content of the collected dust samples. Dust samples were collected at the measuring point located on the roof of five-storey building at the AGH University of Science and Technology in Krakow, Poland (the center of the urban area of the city). In the scope of this study the relations between the carbon and sulfur content within the collected dust samples were determined in the function of the dust fraction content and …


Pomiary Liczby I Wielkości Cząstek Aerozoli W Powietrzu Miejskim Z Wykorzystaniem Metody Optoelektronicznej, Marek Bogacki, Robert Oleniacz, Marian Mazur, Monika Dziugieł Oct 2010

Pomiary Liczby I Wielkości Cząstek Aerozoli W Powietrzu Miejskim Z Wykorzystaniem Metody Optoelektronicznej, Marek Bogacki, Robert Oleniacz, Marian Mazur, Monika Dziugieł

Robert Oleniacz

In the paper some measurement results of number and size for aerosols particles suspended in air achieved using infrared particle sizer IPS-P (Kamika Instruments) with isokinetic air sampling method were presented. In IPS-P analyzer, with measuring range from 0,4 to 300 μm, is applied optical/electronic measurement method which is determined by dimensions of measurement space by aerosols particles motions in a parallel radiation beam. The research was conducted on the roof of four-storey building in Krakow for various meteorological conditions. Results achieved for measured parameters were analysed in terms of selected meteorological factors influence.

English title: Number and size measurements …


Ocena Wielkości Emisji Do Powietrza Z Arcelormittal Poland S.A. Oddział W Krakowie W Odniesieniu Do Standardów Unii Europejskiej, Marian Mazur, Marek Bogacki, Robert Oleniacz Oct 2008

Ocena Wielkości Emisji Do Powietrza Z Arcelormittal Poland S.A. Oddział W Krakowie W Odniesieniu Do Standardów Unii Europejskiej, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The work presents emission factors of main air pollutants for installations of ArcelorMittal Poland S.A. Unit in Krakow (Poland) in comparison with analogous characteristic emissions for iron and steel industry in West Europe. In the comparison four installations (to coke, sinter, pig iron and steel production) were taken into consideration. The emission rates from ArcelorMittal Poland S.A. Unit in Krakow were estimated on the basis of the emission levels and production data from 2004, when took place the most significant production of liquid steel during last several years. As a result of the analysis, most the emission factors (with the …


Real-Time Measurement Of The Size Of Air Particulates, Marek Bogacki, Robert Oleniacz, Marian Mazur, Stanisław Kamiński Jan 2006

Real-Time Measurement Of The Size Of Air Particulates, Marek Bogacki, Robert Oleniacz, Marian Mazur, Stanisław Kamiński

Robert Oleniacz

The gravimetric method of measuring PM10 particulate concentration in air is the reference method used in Poland and in the European Union. To get information on mass fractions of lower diameter particulates (e.g. PM5, PM2,5 or PM1) one usually has to apply various pre-sorters (most often of the impact type). This paper presents a new device that measures air particulate sizes in real time. The device makes it possible to classify (sort) air particulates according to size into 256 granularity classes from about 0.4 µm up to 300 µm. Tests of a device prototype were conducted in Warsaw at the …


Porównanie Poprzedniej I Aktualnej Metodyki Modelowania Rozprzestrzeniania Się Zanieczyszczeń W Powietrzu Opartej Na Modelu Smugi Gaussa, Robert Oleniacz, Marek Bogacki Jan 2004

Porównanie Poprzedniej I Aktualnej Metodyki Modelowania Rozprzestrzeniania Się Zanieczyszczeń W Powietrzu Opartej Na Modelu Smugi Gaussa, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Necessity of adaptation the Polish law in the field of the environment protection to the European Union law caused to adopt new criterions and methods of the air quality assessment. One of the methods of the air quality assessment is modeling of the substance levels in the air based on the calculation of the air pollutant dispersion in the atmosphere. Thus necessary changes also encompassed the basic methodology applied in our country for many years that had made possible calculation of the air pollution caused by existing and new emission sources. After some modifications the computation method was adopted as …


Referencyjna Metodyka Modelowania Poziomów Substancji W Powietrzu Na Tle Innych Modeli Obliczeniowych, Marek Bogacki, Robert Oleniacz Jan 2004

Referencyjna Metodyka Modelowania Poziomów Substancji W Powietrzu Na Tle Innych Modeli Obliczeniowych, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

In the paper some differences between various computational models applied to the atmospheric dispersion modeling were presented. These models each other were compared as regards the expanse-time scale of computation, description way of the wind field and the frame of reference for the air particle moves. Particular attention was paid to the Gauss plume model that was a base for a modeling method of the pollutant levels in the air accepting in Poland as the reference methodology. A general description, applications and limitations of this methodology were presented, as well data essential to the computation, way of the data preparing …


Likwidacja Strefy Ochronnej Huty Katowice I Zakładów Koksowniczych "Przyjaźń" W Dąbrowie Górniczej, Marian Mazur, Robert Oleniacz, Marek Bogacki Oct 2002

Likwidacja Strefy Ochronnej Huty Katowice I Zakładów Koksowniczych "Przyjaźń" W Dąbrowie Górniczej, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Legislation changes in Poland concerning the protective zones (created around industrial plants particularly harmful to the environment) were presented in the paper. Conditions connected with forming, developing and partial elimination of the protective zone existing around the "Katowice" steelworks and the coke plant Przyjaźń in Dąbrowa Górnicza (Poland) since 1978 were characterized as well.

English title: Elimination of the protective zone of the Katowice steelworks and the coke plant Przyjaźń in Dąbrowa Górnicza.


Analiza Możliwości Likwidacji Stref Ochronnych Wokół Wybranych Zakładów Przemysłu Hutniczego I Koksochemicznego, Marian Mazur, Robert Oleniacz, Marek Bogacki Jun 2000

Analiza Możliwości Likwidacji Stref Ochronnych Wokół Wybranych Zakładów Przemysłu Hutniczego I Koksochemicznego, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Polish industrial plants with protective zones delimited in the past, have been faced with the necessity to liquidation of these zones before 2005. At the same time the plants must not cause any harmful influence over environment outside the area which they have title deed to. Determination of the current range of this impact is very important due to the high costs of a possible purchase of land exposed to the harmful effects. The study analyzes the possibility of verifying the course of borders two existing protective zones: around Katowice Steelworks and Coking Plant "Przyjaźń" in Dąbrowa Górnicza (the first …


Modelowanie Stężenia Ozonu W Niskiej Troposferze Na Przykładzie Nowego Sącza, Marek Bogacki, Marek Mazur, Robert Oleniacz Mar 1999

Modelowanie Stężenia Ozonu W Niskiej Troposferze Na Przykładzie Nowego Sącza, Marek Bogacki, Marek Mazur, Robert Oleniacz

Robert Oleniacz

The paper presents the results of research related to the modeling of physicochemical phenomena occurring in the ground layer of the atmosphere in terms of ozone formation. For this purpose, the box model was used, in which the computational area is defined as a space designated by a steady surface and a variable height. Conducted in Nowy Sącz (Poland) experiment confirmed the possibility of using this type of model to diagnose and possibly forecasting ozone concentrations in any area of ​​calculation. The study also showed that the quality of the results depends mainly on accuracy in preparing of input data, …


Modelowanie Imisji Ozonu W Przyziemnej Warstwie Atmosfery Na Przykładzie Nowego Sącza, Marek Bogacki, Marian Mazur, Robert Oleniacz Sep 1998

Modelowanie Imisji Ozonu W Przyziemnej Warstwie Atmosfery Na Przykładzie Nowego Sącza, Marek Bogacki, Marian Mazur, Robert Oleniacz

Robert Oleniacz

The paper presents the results of research related to the modeling of physicochemical phenomena occurring in the ground-layer of the atmosphere in terms of ozone formation. For this purpose, the box model was used, in which the computational area is defined as a space designated by a steady surface and a variable height. Conducted in Nowy Sącz (Poland) experiment confirmed the possibility of using this type of model to diagnose and possibly forecasting ozone concentrations in any area of ​​calculation. The study also showed that the quality of the results depends mainly on accuracy in preparing of input data, especially …


Koncepcja Monitoringu Zanieczyszczeń Powietrza Wokół Elektrowni “Jaworzno Iii” Mobilną Stacją Pomiarową, Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz Jun 1997

Koncepcja Monitoringu Zanieczyszczeń Powietrza Wokół Elektrowni “Jaworzno Iii” Mobilną Stacją Pomiarową, Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz

Robert Oleniacz

The paper presents the concept of air pollution monitoring around the Power Plant "Jaworzno III" (Poland) with the use of the mobile station. Aim of the new monitoring system is to provide information about the current state of air pollution and to enable an assessment of the environmental implications of the use of low-emission burners, run the installation of flue gas desulphurisation and changes in the way of releasing flue gases into the atmosphere. Due to economic, technical and practical the monitoring system was based on a single mobile station. Measurements will be carried out in a random scheme at …


Wdrażanie Monitoringu Zanieczyszczeń Powietrza Atmosferycznego W Kielcach, Marian Mazur, Robert Oleniacz, Marek Bogacki Dec 1996

Wdrażanie Monitoringu Zanieczyszczeń Powietrza Atmosferycznego W Kielcach, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Assumptions for regional environmental monitoring in the province of Kielce were developed as early as 1992. Since the beginning of particular attention were monitoring the air. The article presents the next step in the implementation of this monitoring, associated with verification of the location and the measuring range of points to measure the concentrations of air pollutants in Kielce. As a result of analysis and calculations, it was found that the original location is not always correct and does not reflect the spatial differentiation of pollutant concentrations. The proposed changes in the position of monitoring points or measurement methods were …


Zastosowanie Metody Obliczeniowo-Pomiarowej Do Oceny Stanu Zanieczyszczenia Powietrza W Nowym Sączu, Marian Mazur, Marek Bogacki, Robert Oleniacz Dec 1996

Zastosowanie Metody Obliczeniowo-Pomiarowej Do Oceny Stanu Zanieczyszczenia Powietrza W Nowym Sączu, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

Assessment of the state of air pollution in the urban area is a difficult and complex task. Depending on the method of assessment the procedure requires a comprehensive research and calculations of air emissions from all sources occurring in the area and the use of atmospheric dispersion models or large-scale implementation of direct measurements of air pollutant concentrations. Both of these methods may also be applied simultaneously to their mutual verification.

The article presents the results of such a comprehensive assessment of air pollution on the example of the city of Nowy Sacz (Poland). This involved determining the emissions of …


Monitoring Zanieczyszczeń Powietrza Wokół Elektrowni "Jaworzno Iii", Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz Sep 1996

Monitoring Zanieczyszczeń Powietrza Wokół Elektrowni "Jaworzno Iii", Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz

Robert Oleniacz

The article presents the concept of system of monitoring of air pollution around the Power Plant "Jaworzno III" in Jaworzno (Poland), whose objective is to evaluate the impact of this object on air quality. This system is based on a few measuring points and a mobile station should also allow for the assessment of ecological effects associated with the use of low-emission burners in power boilers (reduction of NOx emission) and run the wet installation of flue gas desulfurization (reduction of SO2 emission). An additional aim of the measurements is to identify the possible effects of a changes in the …


Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz Sep 1996

Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The paper presents the results of a comprehensive assessment of air pollution in the city of Nowy Sącz (Poland). This involved determining the emissions of selected pollutants from various sources with their percentages of the total emission and immission on the area under consideration. As a result of measurement of concentrations of particulate matter and benzo(a)pyrene in several parts of the city were verified results of theoretical calculations and determined the size of the inflow of pollutants from outside the area in question.

English title: A comprehensive assessment of air quality in Nowy Sącz using computational and measuring methods.


Prognozowanie Wpływu Motoryzacji Na Poziom Stężenia Ozonu W Przyziemnej Warstwie Atmosfery, Marek Bogacki, Marian Mazur, Robert Oleniacz Sep 1996

Prognozowanie Wpływu Motoryzacji Na Poziom Stężenia Ozonu W Przyziemnej Warstwie Atmosfery, Marek Bogacki, Marian Mazur, Robert Oleniacz

Robert Oleniacz

The paper presents an approach for assessing the impact of road transport on the level of ozone concentrations in the ground layer of the atmosphere. The developed method consists in emission inventory on the analyzed area for road transport and calculations using the model of chemical reactions in the troposphere.

Using this method it is possible to display waveforms daily ozone concentrations in the air, and evaluate the effectiveness of the decisions related to the prevention of occurrence of photochemical smog in urban and industrial agglomerations.

English title: Predicting the impact of motoring on the level of ozone concentration in …


Zastosowanie Modelowania Matematycznego Do Oceny Zanieczyszczenia Powietrza Powodowanego Przez Motoryzację, Marian Mazur, Robert Oleniacz, Bożena Biernat-Oleniacz Dec 1995

Zastosowanie Modelowania Matematycznego Do Oceny Zanieczyszczenia Powietrza Powodowanego Przez Motoryzację, Marian Mazur, Robert Oleniacz, Bożena Biernat-Oleniacz

Robert Oleniacz

The paper presents the results of an inventory of sources of air emissions from the city of Nowy Sacz (Poland) with regard to pollutant emissions from road transport, industrial processes, combustion plants and low-emissions from household furnaces. Particular attention has been devoted to assessing the impact of traffic on air quality in the city. Specified share of emissions from motor vehicles in the state of air pollution in the city center and its outskirts using the method of the atmospheric dispersion modeling.

English title: The use of mathematical modeling to assess air pollution caused by road transport.


Ocena I Weryfikacja Lokalizacji Stanowisk Pomiarowych Imisji Zanieczyszczeń Powietrza W Województwie Kieleckim, Marian Mazur, Robert Oleniacz Jun 1995

Ocena I Weryfikacja Lokalizacji Stanowisk Pomiarowych Imisji Zanieczyszczeń Powietrza W Województwie Kieleckim, Marian Mazur, Robert Oleniacz

Robert Oleniacz

The paper presents the implementation of air pollution monitoring in the province of Kielce (Poland), associated with verification of the location and the measuring range of points to measure the concentrations of air pollutants. For this purpose were used calculations of the pollutants dispersion and statistical analysis of measurement results obtained on existing measuring stations. In the statistical calculations were used analysis of variance homogeneity, based on Cochran, Bartlett and Hartley tests. As a result of analysis and calculations, it was found that the original location is not always correct and does not reflect the spatial differentiation of pollutant concentrations. …