Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 11 of 11

Full-Text Articles in Engineering

A Comparative Study Of Magnetic Behaviors In Tbni2, Tbmn2 And Tbni2mn, Jianli Wang, M F. Md Din, Shane Kennedy, F Hong, Stewart J. Campbell, A J. Studer, G H. Wu, Zhenxiang Cheng, S X. Dou Oct 2014

A Comparative Study Of Magnetic Behaviors In Tbni2, Tbmn2 And Tbni2mn, Jianli Wang, M F. Md Din, Shane Kennedy, F Hong, Stewart J. Campbell, A J. Studer, G H. Wu, Zhenxiang Cheng, S X. Dou

Shi Xue Dou

All TbNi2, TbMn2, and TbNi2Mn compounds exhibit the cubic Laves phase with AB2-type structure in spite of the fact that the ratio of the Tb to transition-metal components in TbNi2Mn is 1:3. Rietveld refinement indicates that in TbNi2Mn the Mn atoms are distributed on both the A (8a) and B (16d) sites. The values of the lattice constants were measured to be a = 14.348 Å (space group F-43 m), 7.618 Å, and 7.158 Å (space group Fd-3 m) for TbNi2, TbMn2, and TbNi2Mn, respectively. The magnetic transition temperatures TC were found to be TC = 38 K and TC …


A Laboratory Study Of Railway Ballast Behaviour Under Various Fouling Degree, Cholachat Rujikiatkamjorn, Buddhima Indraratna, Ngoc Trung Ngo, Matthew Coop Mar 2014

A Laboratory Study Of Railway Ballast Behaviour Under Various Fouling Degree, Cholachat Rujikiatkamjorn, Buddhima Indraratna, Ngoc Trung Ngo, Matthew Coop

Cholachat Rujikiatkamjorn

This paper presents a laboratory study of interface behavior between ballast and geogrid under various degree of fouling by coal fines. The stress-displacement behaviour of fresh and fouled ballast with geogrid was investigated through a series of large-scale direct shear tests where the fouling degree varied from 0% to 95% Void Contamination Index (VCI), at normal stresses ranging from 15kPa to 75kPa. The results showed that geogrid enhances the shear strength and increases apparent angle of shearing resistance, while only slightly reduces the vertical displacement of the composite geogrid-ballast system. However, when ballast was contaminated by coal fines, the influences …


Laboratory Study Of Small-Strain Behavior Of A Compacted Silty Sand, Ana Heitor, Buddhima Indraratna, Cholachat Rujikiatkamjorn Mar 2014

Laboratory Study Of Small-Strain Behavior Of A Compacted Silty Sand, Ana Heitor, Buddhima Indraratna, Cholachat Rujikiatkamjorn

Cholachat Rujikiatkamjorn

Small-strain behavior is a key indicator for assessing the performance of compacted fills. Compaction conditions, i.e., initial moisture content and applied energy, govern compaction effectiveness and thus, the structure and matric suction of compacted soil. This paper presents an experimental study of the small-strain behavior of compacted silty sand prepared with different compaction conditions. Specimens with varying initial moisture contents and compaction energies were tested with bender elements to determine the small-strain shear modulus (G0), while the post-compaction matric suction was measured using the filter paper method and tensiometer. The experimental data suggest a pronounced relationship between G0 and the …


A Laboratory Study Of Railway Ballast Behaviour Under Various Fouling Degree, Cholachat Rujikiatkamjorn, Buddhima Indraratna, Ngoc Trung Ngo, Matthew Coop Mar 2014

A Laboratory Study Of Railway Ballast Behaviour Under Various Fouling Degree, Cholachat Rujikiatkamjorn, Buddhima Indraratna, Ngoc Trung Ngo, Matthew Coop

Buddhima Indraratna

This paper presents a laboratory study of interface behavior between ballast and geogrid under various degree of fouling by coal fines. The stress-displacement behaviour of fresh and fouled ballast with geogrid was investigated through a series of large-scale direct shear tests where the fouling degree varied from 0% to 95% Void Contamination Index (VCI), at normal stresses ranging from 15kPa to 75kPa. The results showed that geogrid enhances the shear strength and increases apparent angle of shearing resistance, while only slightly reduces the vertical displacement of the composite geogrid-ballast system. However, when ballast was contaminated by coal fines, the influences …


Experimental Study On The Effectiveness Of Prefabricated Vertical Drains Under Cyclic Loading, Cholachat Rujikiatkamjorn, Buddhima Indraratna, Guanghui Meng Mar 2014

Experimental Study On The Effectiveness Of Prefabricated Vertical Drains Under Cyclic Loading, Cholachat Rujikiatkamjorn, Buddhima Indraratna, Guanghui Meng

Buddhima Indraratna

This study is an attempt to investigate the effectiveness of a prefabricated vertical drain (PVD) installed in remoulded soft clay, where a large-scale cyclic triaxial process simulation rig was employed to simulate cyclic loading representing a track environment. The experimental data show that PVD successfully prevents excessive accumulation of pore water pressure during cyclic loading, and their dissipation continues to occur after the load is removed. The findings of this study have direct significance to rail track environments, e.g. in coastal Australia, where PVD installation beneath rail tracks constructed on low-lying estuarine soils has been recently adopted.


Laboratory Study Of Small-Strain Behavior Of A Compacted Silty Sand, Ana Heitor, Buddhima Indraratna, Cholachat Rujikiatkamjorn Mar 2014

Laboratory Study Of Small-Strain Behavior Of A Compacted Silty Sand, Ana Heitor, Buddhima Indraratna, Cholachat Rujikiatkamjorn

Buddhima Indraratna

Small-strain behavior is a key indicator for assessing the performance of compacted fills. Compaction conditions, i.e., initial moisture content and applied energy, govern compaction effectiveness and thus, the structure and matric suction of compacted soil. This paper presents an experimental study of the small-strain behavior of compacted silty sand prepared with different compaction conditions. Specimens with varying initial moisture contents and compaction energies were tested with bender elements to determine the small-strain shear modulus (G0), while the post-compaction matric suction was measured using the filter paper method and tensiometer. The experimental data suggest a pronounced relationship between G0 and the …


Microstructures Of Conducting Polymers: Patterning And Actuation Study, Babita Gaihre, Bo Weng, Syed A. Ashraf, Geoffrey M. Spinks, Peter C. Innis, Gordon G. Wallace Mar 2014

Microstructures Of Conducting Polymers: Patterning And Actuation Study, Babita Gaihre, Bo Weng, Syed A. Ashraf, Geoffrey M. Spinks, Peter C. Innis, Gordon G. Wallace

Gordon Wallace

The conducting polymers exhibit electrochemically driven expansion and shrinkage due to ingress and egress of dopant ions in response to potential applied. In this paper, we report on patterning of microdots and microsquares of polypyrrole (PPy), poly(3,4-ethylenedioxythiophene) (PEDOT) and poly(3,3-dihexyl-3-4-dihydro-2H-thieno[3,4b][1,4]-dioxepine PProDOT(Hx) 2 and their behaviour under voltage change. Stainless steel mesh was used to deposit microdots and inkjet-printed cellulose girds were used to deposit microsqures of the conducting polymers on the ITO surface. It was found that PPy showed distinct actuation in the z direction while colour change was prominent in the case of PEDOT and PProDOT(Hx)2.


Aging Effect Evolution During Ferroelectric-Ferroelectric Phase Transition: A Mechanism Study, Zuyong Feng, Zhenxiang Cheng, Dongqi Shi, S X. Dou Mar 2014

Aging Effect Evolution During Ferroelectric-Ferroelectric Phase Transition: A Mechanism Study, Zuyong Feng, Zhenxiang Cheng, Dongqi Shi, S X. Dou

Shi Xue Dou

Aging can significantly modify the dielectric, piezoelectric, and ferroelectric performance of ferroelectrics. However, little attention has been paid to the aging effect during ferroelectric-ferroelectric phase transitions that is essentially correlated with real applications. In this letter, the authors report the aging effect evolution between two ferroelectric phases in an acceptor-doped piezoceramics. The results show that aging-induced double hysteresis loops were exhibited in different ferroelectric phases, but disappeared during ferroelectric-ferroelectric phase transitions, suggesting the mechanism that the intrinsic restoring force for the reversible switching of domains caused by the alignment of defect dipoles was weakened due to ferroelectric dipole reorientation.


Neutron Diffraction Study Of Mnniga2 - Structural And Magnetic Behaviour, Jianli Wang, L Ma, M Hofmann, M Avdeev, S J. Kennedy, S J. Campbell, M F. Md Din, M Hoelzel, G H. Wu, S X. Dou Mar 2014

Neutron Diffraction Study Of Mnniga2 - Structural And Magnetic Behaviour, Jianli Wang, L Ma, M Hofmann, M Avdeev, S J. Kennedy, S J. Campbell, M F. Md Din, M Hoelzel, G H. Wu, S X. Dou

Shi Xue Dou

MnNiGa2 crystallizes in the L21 (Heusler) structure and has a ferromagnetic ordering temperature TC ∼ 192 K. Rietveld refinement of the neutron diffraction patterns indicates that the Ga atoms occupy the equivalent 8c position, while Mn and Ni share the 4a (0, 0, 0) and 4b (0.5, 0.5, 0.5) sites with a mixed occupancy of Mn and Ni atoms. It is found that that ∼83% of Mn and ∼17% Ni are located at the 4a site while ∼83% of Ni and ∼17% Mn occupy the 4b site. There is no evidence of a magneto-volume effect around TC. In agreement with …


The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld Feb 2014

The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld

Stéphanie Corde

High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly 192Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 uGy m2/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the …


Similarity-Based Search For Model Checking: A Pilot Study With Java Pathfinder, Elmin Ibrahimov, Jixing Wang, Zhiquan Zhou Jan 2014

Similarity-Based Search For Model Checking: A Pilot Study With Java Pathfinder, Elmin Ibrahimov, Jixing Wang, Zhiquan Zhou

Dr Zhiquan Zhou

When a model checker cannot explore the entire state space because of limited resources, model checking becomes a kind of testing with an attempt to find a failure (violation of properties) quickly. We consider two state sequences in model checking: (i) the sequence in which new states are generated, and (ii) the sequence in which the states generated in sequence (i) are checked for property violation. We observe that neighboring states in sequence (i) often have similarities in certain ways. Based on this observation we propose a search strategy, which generates sequence (ii) in such a way that similar states …