Full-Text Articles in Engineering

Rapid In-Situ Load Testing, Purdue Ect Team Jan 2007

Rapid In-Situ Load Testing, Purdue Ect Team

ECT Fact Sheets

Load tests and structural monitoring are used to gain information regarding the health and performance of an existing structure. Both are more representative than analytical approaches to evaluate the structure, especially when little is known about the structure's geometry and composition. Rapid in-situ load testing is intended to be much simpler and can be carried out in a fraction of the time and at a much lower cost. The testing procedure was originally developed at Center for Infrastructure Engineering Studies, University of Missouri-Rolla to offer a non-destructive yet conclusive demonstration of the performance of new construction techniques and technologies.


Hybrid Computerized Decision Support System For Infrastructure Assessment, Purdue Ect Team Jan 2007

Hybrid Computerized Decision Support System For Infrastructure Assessment, Purdue Ect Team

ECT Fact Sheets

Currently, assessment techniques are performed subjectively, time consuming, and rely mostly on human visual inspection. Such subjective assessment methods have been identified as a critical obstacle to effective infrastructure management. The hybrid computerized decision support system for construction quality assessment applies concepts in the fields of machine learning, pattern recognition, and image processing. The system will automate the assessment process by acquiring digital images of the areas to be assessed and analyzing the images to identify and measure defects. Moreover, sample images will be used to train the system to acquire expert knowledge in identifying the defects and using this …


Site Characterization And Analysis Penetrometer System (Scaps) : Assessing Site Cotamination, Purdue Ect Team Jan 2007

Site Characterization And Analysis Penetrometer System (Scaps) : Assessing Site Cotamination, Purdue Ect Team

ECT Fact Sheets

While a number of techniques exist for the remediation of contaminated soils, one of the largest problems is often the initial site assessment. It can be a difficult, expensive and time-consuming process to determine the exact extent of site contamination. The U.S. Army Engineer Waterways Experiment Station (WES) under the sponsorship of the U.S. Army Environmental Center (AEC) initiated the development of the Site Characterization and Analysis Penetrometer System (SCAPS) Research, Development, and Technology Demonstration Program to provide the Department of Defense (DoD) with a rapid and cost-effective means to characterize soil conditions at DoD sites undergoing installation restoration (cleanup).