Correlation Of Weir Crest Depth, Froude Number, H/P Ratio, Weir Thickness, Paul Harrawood Jan 1956

Correlation Of Weir Crest Depth, Froude Number, H/P Ratio, Weir Thickness, Paul Harrawood

Masters Theses

"1. The Froude number criterion for weir flow was shown to be sound and accurate by experimental verification of the theoretical correlation of Froude number and critical depth. It was proved that sub-critical, critical and super-critical flows are correctly identified by the Froude number.

2. In order to accurately determine the Froude number, the actual flow section at the weir crest must be known. Because of end contractions, it does not have the same dimensions as the weir opening. For the Cipoletti weir, it is the product of the length of the crest and the crest depth, i.e., A= by. …