Empirical Evaluation Of The Eccentric Orifice In Small Diameter Pipes, Gary A. Hinz Jan 1966

Empirical Evaluation Of The Eccentric Orifice In Small Diameter Pipes, Gary A. Hinz

Masters Theses

"This investigation has taken different orifice sizes (0.3005", 0.4000", 0.5045", 0.6015") and tested their flow characteristics when used in a 1" diameter pipe. Each orifice was initially placed in a fully eccentric position, that is the circumference of the orifice was placed tangent to the inside circumference of the pipe. Data was taken with the orifice eccentric to concentric in increments of 0.050".

Plots of flow coefficient versus Reynold's number were made for each position of the four orifices tested.

Empirical equations were developed for determining the flow coefficient of the various orifice sizes placed in any eccentric position.

It …