Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 19 of 19

Full-Text Articles in Engineering

Comparisons Of Concrete Slender Wall Software With Full-Scale Experiments, Gloriana M.L. Moua Dec 2021

Comparisons Of Concrete Slender Wall Software With Full-Scale Experiments, Gloriana M.L. Moua

Architectural Engineering

The 1980 slender wall testing was performed by the Structural Engineers Association of Southern California (SEAOSC) in efforts to analyze behavior of concrete slender walls when lateral and eccentric axial loads are applied. The testing was done with 12 tilt-up wall panels, 3 of each of the four thicknesses: 9 ½”, 7 ¼”, 5 ¾”, and 4 ¾”. What was discovered from testing was that a fixed limitation of height to thickness ratio was not a governing factor and that each case should be analyzed based off the strength and deflection of the wall. It was because of this testing …


Fire Protection System Analysis Of Air National Guard Readiness Center, Steven A. Waidelich Sep 2021

Fire Protection System Analysis Of Air National Guard Readiness Center, Steven A. Waidelich

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes the impact of a fire located in the atrium at the Air National Guard Readiness Center (ANGRC) located at Joint Base Andrews, Maryland. The fifth floor is an enclosed penthouse used to enclose mechanical and electrical equipment. International Building Code (IBC) 2006 and 2005, section 506.1, excludes elevator penthouses of this type from the height and area calculations. The four occupied floors are used for office areas with the three- story atrium opening onto the balcony of the second- and the third-floor office area, and the second-floor conference center.

The prescriptive portion of this analysis looked at …


Bonderson Engineering Center, Hannah Curry Sep 2021

Bonderson Engineering Center, Hannah Curry

Fire Protection Engineering: Culminating Experience Project Reports

As part of the requirements for receiving a Master of Science in Fire Protection Engineering from California Polytechnic State University at San Luis Obispo, a Fire and Life Safety Analysis of the Bonderson Engineering Projects Center located on the Cal Poly San Luis Obispo campus is performed. The analysis consists of both a prescriptive and a performance-based analysis.

The prescriptive analysis focuses on reviewing the as-built conditions within the Bonderson Engineering Projects Center for compliance with the current edition of applicable codes and standards. The analysis is performed using the 2018 Edition of the International Building Code (IBC) and the …


A Fire Protection Life Safety Analysis Of Multipurpose Building, Dalower Hossain Aug 2021

A Fire Protection Life Safety Analysis Of Multipurpose Building, Dalower Hossain

Fire Protection Engineering: Culminating Experience Project Reports

The following report is a fire and hazard protection analysis of a new building. This new building is a multi-purpose building called MPB locates in Gazipur, Dhaka, Bangladesh. The prescriptive requirements set by the codes and standards used at time of construction of the building have been met. The building has been properly classified with respect to occupancy as S1, Group B and F-1 and construction Type I A Sprinklered. Appropriate designs for interior partitions and exterior wall have been identified. Interior finish requirements have been analyzed for a better understanding of aesthetics guidelines. Based on the sprinkler drawing calculations, …


Construction Innovation Center At California Polytechnic State University, James Hunter Gildart Jun 2021

Construction Innovation Center At California Polytechnic State University, James Hunter Gildart

Fire Protection Engineering: Culminating Experience Project Reports

The building of interest for this project is the Construction Innovation Center (CIC) at California Polytechnic State University, San Luis Obispo. The CIC consists of 3 structures (buildings A, B, and C) equipped throughout with a wet pipe automatic sprinkler system and a fire alarm system with smoke detection. This report reviews the prescriptive and performance-based requirements along with providing a fire safety management plan. The prescriptive based portion of this report covers egress, fire alarm, automatic fire sprinklers, flammability, and structural fire protection requirements. Upon completion of the prescriptive code analysis comparing the CIC to the 2015 International Building …


College Sports Center Fire Protection Analysis, Elijah Kimmig Jun 2021

College Sports Center Fire Protection Analysis, Elijah Kimmig

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this project was to analyze and compare the existing fire protection systems in the college sports center to current applicable codes and standards. Both prescriptive based analysis and performance based analyses were performed.

The prescriptive based analyses included analyzing the structural fire protection, fire suppression, fire alarm, and egress systems. Overall, the majority of the fire protection systems appeared to meet the requirements of the current codes but there are a few items that were found that appear to not meet current code. These items are listed below along with recommendations to mitigate: (1) Placement of certain …


Fire Protection And Life Safety Analysis Of Art ‘N Motion, Jordan Albrecht Jun 2021

Fire Protection And Life Safety Analysis Of Art ‘N Motion, Jordan Albrecht

Fire Protection Engineering: Culminating Experience Project Reports

This report includes a fire protection and life safety analysis for the Art ‘n Motion building. This analysis was done to fulfill the requirement for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University. The Art ‘n Motion building is two (2) stories, approximately 17,720 sqft, and is Type III-B construction. The building’s primary use is a vehicle showroom business where multiple exotic and antique vehicles are on display, and can be bought and sold. The building is also used as a home base for a NASCAR team, that operates out of the garage area …


Husky Union Building - University Of Washington Fire And Life Safety Overview And Analysis, Dan Quatier Jun 2021

Husky Union Building - University Of Washington Fire And Life Safety Overview And Analysis, Dan Quatier

Fire Protection Engineering: Culminating Experience Project Reports

A fire and life safety analysis was performed on the Husky Union Building, which is the student union building on the campus of the University of Washington in Seattle, WA. This analysis was performed for the fulfillment of requirements for the Master of Science in Fire Protection Engineering degree from California Polytechnic State University San Luis Obispo.

The analysis includes both a prescriptive-based and a performance-based design. The prescriptive analysis includes the following elements: (1) Building Code Overview, (2) Egress Analysis and Design, (3) Fire Alarm and Detection, (4) Water-Based Suppression Systems, and (5) Structural Fire Protection

The prescriptive analysis …


California Polytechnic State University – San Luis Obispo Building 180: Baker, Kelly Kessloff Jun 2021

California Polytechnic State University – San Luis Obispo Building 180: Baker, Kelly Kessloff

Fire Protection Engineering: Culminating Experience Project Reports

This project was performed as part of the requirements for completion of the Fire Protection Engineering Master’s Program at Cal Poly. This project covers a full prescriptive and performance based analysis on the Warren J. Baker Center for Science and Mathematics. This building was constructed on Cal Poly’s campus in 2013 and serves occupancies such as classrooms, laboratories, and office space for students and professors.

The prescriptive based analysis of this report will analyze the applicable building codes and determine if this building is compliant. Relevant codes include the 2016 California Building and the 2016 California Fire Code. In addition …


Web Application For Surf Journaling, Zachary James Hislop Jun 2021

Web Application For Surf Journaling, Zachary James Hislop

Computer Engineering

Before deciding whether to surf, many surfers consult surf forecast services. Current surf forecasting offerings provide general information such as predicted surf height and a condition rating, but these predictions are often misleading, as widely varying swell conditions can receive the same forecast. Additionally, these existing services do not incorporate user feedback into their predictions, which requires users to keep a mental mapping of trends between forecast information and real-life conditions.

This report describes the design and implementation of a web application where users can record the surf conditions and assign ratings to recorded surf sessions. With historical surf conditions …


B-91 Fire Protection Analysis, Evan Phillips Jun 2021

B-91 Fire Protection Analysis, Evan Phillips

Fire Protection Engineering: Culminating Experience Project Reports

B-91 is a multiuse building on a Department of Defense installation rented out to a defense contractor consisting of laboratory, office, storage, and utility spaces. To determine the adequacy of the building’s fire protection systems as determined by the state-adopted 2015 International Building Code, a prescriptive analysis was performed with specific areas of focus on the building construction and occupancy, emergency egress capacity, fire suppression systems, and fire alarm systems. The building is compliant with code requirements in its construction and the fire alarm systems are adequately designed to provide notice, but the egress from the building’s main conference room …


Sole On The Ocean Hotel, Dale Mcdowell Jun 2021

Sole On The Ocean Hotel, Dale Mcdowell

Fire Protection Engineering: Culminating Experience Project Reports

The following is an analysis of the fire protection systems and services at the Sole On The Ocean, Hotel (pronounced So-lay), Restaurant and Parking Building, located in Sunny Isles (Miami), Florida. Sole is used for temporary sleeping accommodations, business conference and restaurant purposes. The building is considered a high-rise building and is 24 Stories tall. The building occupancy classification is mixed used for Hotel (Residential), Restaurant (Assembly) and Parking (Storage). The prescriptive analysis was based on the Florida Building Code (FBC) which is identical to the International Building Code (IBC) with a few addendums. This report will adhere to the …


Warren J. Baker Center For Science And Mathematics California Polytechnic State University, San Luis Obispo Campus, Matthew Hudson Jun 2021

Warren J. Baker Center For Science And Mathematics California Polytechnic State University, San Luis Obispo Campus, Matthew Hudson

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze the Warren J Baker Center for Science and Math on the California Polytechnic State University, San Luis Obispo campus. Baker Science is primarily used for classroom and laboratory instruction of college students, with study spaces, faculty offices, and assembly spaces. There are mechanical, electrical, and storage spaces ancillary to the main building functions. The building comprises six floors that are between 23,000 and 44,000 ft2. The first floor contains classrooms, faculty offices, mechanical/electrical spaces, and an auditorium with fixed seating. An atrium connects floors two through five. There are walkways running down …


Nursing Home Study- Culminating Project Final Report, Ed Hale Jun 2021

Nursing Home Study- Culminating Project Final Report, Ed Hale

Fire Protection Engineering: Culminating Experience Project Reports

This project report is a component of the culminating project required by the California Polytechnic State University, Master of Science, Fire Protection Engineering program. The purpose is to demonstrate the student’s comprehensive knowledge, skill, and ability to evaluate fire and life safety engineering principles utilizing both prescriptive and performance- based design as applied to the built environment. The student project building is a two-story, 78-bed, federally funded, government owned, skilled nursing facility with 90% of the occupants being mobility impaired.

The project building was designed and constructed using prescriptive codes. Fire and life safety structural components, means of egress, fire …


Fire Protection Analysis For The Tritium Engineering Building, Jack Smeck Jun 2021

Fire Protection Analysis For The Tritium Engineering Building, Jack Smeck

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzed several different aspects of the fire protection and life safety strategy for the Tritium Engineering Building (TEB) at the Savannah River Site in Aiken, SC. The TEB is a single-story, Type IIB building that primarily houses engineering and technical staff. The building is approximately 15,560 ft2 and consists of two large “open areas” enclosed by hard- wall offices. Modular workstations are located in both “open areas” and accommodate the majority of the building occupants. This analysis provided both a prescriptive and a performance-based approach for analyzing fire hazards within the building. The prescriptive- based analysis evaluated the …


Tucson Student Housing, Abraham Coria Jun 2021

Tucson Student Housing, Abraham Coria

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to perform a two-part analysis of Tucson Student Housing’s fire protection design components. The two-part analysis consists of a prescriptive analysis, and a performance-based analysis. The purpose of the prescriptive-based analysis is to verify Tucson Student Housing meets or exceeds applicable construction standards. The prescriptive based analysis reviews the fire resistance of building elements, flammability of interior finishes, wet suppression system, fire alarm system, voice evacuation system, and occupant egress requirements. The performance-based analysis evaluates the performance of Tucson Student Housing’s fire protection systems when subjected to specified design fires. The design fire scenarios …


Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag Jun 2021

Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag

Fire Protection Engineering: Culminating Experience Project Reports

The Canyon Vista Dining project is a renovation of an existing two-story dining facility located in the Warren College area of the University of California San Diego campus for the owners, Housing, Dining and Hospitality. The renovation scope of work comprised a new dining experience with a better diversity of food options and indoor and outdoor seating, which upgraded the first floor, second floor, and mechanical penthouse. In the course of the design and construction, the prescriptive, performance, wildfire, and due diligence design results were utilized during discussions with design team and building permit approval. The project construction was completed …


Fire Protection Analysis Of Johnson Controls Office Building, Derek Driscoll Jun 2021

Fire Protection Analysis Of Johnson Controls Office Building, Derek Driscoll

Fire Protection Engineering: Culminating Experience Project Reports

This project report contains a fire and life safety analysis of the Johnson Controls Office Building. The building is located in Los Angeles, California. The building is a mixed use occupancy with office spaces, meeting rooms, training rooms, and a warehouse for storing fire sprinkler and fire alarm materials. The building is one level with a mezzanine. It is attached to another building and separated by fire barrier so that they are considered separate buildings. This report contains a prescriptive analysis and a performance-based design analysis of the building.

The prescriptive code requirements were determined based on the 2019 edition …


Study Of Fragility Functions For Assessing Damage To Water Pipe Networks Caused By Earthquake Loading, Dylan Joseph Merlo Apr 2021

Study Of Fragility Functions For Assessing Damage To Water Pipe Networks Caused By Earthquake Loading, Dylan Joseph Merlo

Master's Theses

The performance of water lifelines during seismic events is an area of ongoing research. In this study we evaluate eight (8) different seismic events and the impact that ground shaking and ground deformations had on water pipeline systems. The overall goal of this work is to provide municipalities and utility providers with tools for mitigating the consequences of seismic hazards on water lifeline systems by analyzing the accuracy of damage estimation models. Three (3) different repair rate models are evaluated using data collected from the seismic events and compared to observed repair rate data. Results are analyzed to examine the …