Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Engineering

The Effects Of Cure Schedule On Properties Of Glass-Fiber Reinforced Epoxy Matrix Composites, Trevor J. Lee Jun 2011

The Effects Of Cure Schedule On Properties Of Glass-Fiber Reinforced Epoxy Matrix Composites, Trevor J. Lee

Materials Engineering

Two different two-component resin systems were cured, via Differential Scanning Calorimetry, for the times recommended by their respective manufacturers. The resin cure schedules were designed to simulate typical and attainable processing conditions; they were cured at 120°F, 140°F, and 160°F, and in-mold post-cured at 200°F, 230°F, and 260°F. The resulting scans were then compared to a baseline cure for each resin system, consisting of two heating-cooling cycles at a constant rate of temperature change. These baseline cures were then used to determine the percent cure of each sample and the shift in glass transition temperature between the baseline cure and …


The Design And Manufacture Of A Microfluidic Reactor For Synthesis Of Cadmium Selenide Quantum Dots Using Silicon And Glass Substrates, Peter Gonsalves Jun 2011

The Design And Manufacture Of A Microfluidic Reactor For Synthesis Of Cadmium Selenide Quantum Dots Using Silicon And Glass Substrates, Peter Gonsalves

Materials Engineering

A microfluidic reactor for synthesizing cadmium selenide (CdSe) quantum dots (QDs) was synthesized out of silicon and Pyrex glass. Microfabrication techniques were used to etch the channels into the silicon wafer. Holes were wet-drilled into Pyrex glass using a diamond-tip drill bit. The Pyrex wafer was aligned to the etched silicon wafer and both were anodically bonded to complete the microfluidic reactor. Conditions for anodic bonding were created by exposing the stacked substrates to 300V at ~350oC under 5.46N of force. Bulk CdSe solution was mixed at room temperature and treated as a single injection. The syringe containing …


Characterization Of The Relationship Between The Microstructure And Tensile Strength Of Annealed Ti-6al-4v, Aldo Corona Jun 2011

Characterization Of The Relationship Between The Microstructure And Tensile Strength Of Annealed Ti-6al-4v, Aldo Corona

Materials Engineering

Tensile coupons of Ti-6Al-4V were heat treated at varying annealing temperatures from 1200°F (648°C) to 1450°F (787°C) at 50°F (23°C) increments for 1 hour. The samples were air cooled to room temperature or furnace cooled to 800°F (426°C) followed by air cooling to room temperature. Four tensile coupons were treated at each annealing temperature and cooling rate. Alpha case was observed to form on the surface of the samples post heat treatment with a maximum depth of 25 µm (.001 in). Samples were tensile tested for their ultimate tensile strength, yield strength, and percent elongation. Samples across all annealing temperatures …