Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 14 of 14

Full-Text Articles in Engineering

Electropermeabilization Does Not Correlate With Plasma Membrane Lipid Oxidation, Olga Michel, Andrei G. Pakhomov, Maura Casciola, Jolanta Saczko, Julita Kulbacka, Olga N. Pakhomova Dec 2019

Electropermeabilization Does Not Correlate With Plasma Membrane Lipid Oxidation, Olga Michel, Andrei G. Pakhomov, Maura Casciola, Jolanta Saczko, Julita Kulbacka, Olga N. Pakhomova

Bioelectrics Publications

The permeabilized condition of the cell membrane after electroporation can last minutes but the underlying mechanisms remain elusive. Previous studies suggest that lipid peroxidation could be responsible for the lasting leaky state of the membrane. The present study aims to link oxidation within the plasma membrane of live cells to permeabilization by electric pulses. We have introduced a method for the detection of oxidation by ratiometric fluorescence measurements of BODIPY-C11 dye using total internal reflection fluorescence (TIRF) microscopy, limiting the signal to the cell membrane. CHO-K1 cells were cultured on glass coverslips coated with an electroconductive indium tin oxide (ITO) …


Label-Free Microrna Optical Biosensors, Meimei Lai, Gymama Slaughter Nov 2019

Label-Free Microrna Optical Biosensors, Meimei Lai, Gymama Slaughter

Bioelectrics Publications

MicroRNAs (miRNAs) play crucial roles in regulating gene expression. Many studies show that miRNAs have been linked to almost all kinds of disease. In addition, miRNAs are well preserved in a variety of specimens, thereby making them ideal biomarkers for biosensing applications when compared to traditional protein biomarkers. Conventional biosensors for miRNA require fluorescent labeling, which is complicated, time-consuming, laborious, costly, and exhibits low sensitivity. The detection of miRNA remains a big challenge due to their intrinsic properties such as small sizes, low abundance, and high sequence similarity. A label-free biosensor can simplify the assay and enable the direct detection …


Paper-Based Flexible Electrode Using Chemically-Modified Graphene And Functionalized Multiwalled Carbon Nanotube Composites For Electrophysiological Signal Sensing, Md Faruk Hossain, Jae Sang Heo, John Nelson, Insoo Kim Oct 2019

Paper-Based Flexible Electrode Using Chemically-Modified Graphene And Functionalized Multiwalled Carbon Nanotube Composites For Electrophysiological Signal Sensing, Md Faruk Hossain, Jae Sang Heo, John Nelson, Insoo Kim

Bioelectrics Publications

Flexible paper-based physiological sensor electrodes were developed using chemically-modified graphene (CG) and carboxylic-functionalized multiwalled carbon nanotube composites (f@MWCNTs). A solvothermal process with additional treatment was conducted to synthesize CG and f@MWCNTs to make CG-f@MWCNT composites. The composite was sonicated in an appropriate solvent to make a uniform suspension, and then it was drop cast on a nylon membrane in a vacuum filter. A number of batches (0%~35% f@MWCNTs) were prepared to investigate the performance of the physical characteristics. The 25% f@MWCNT-loaded composite showed the best adhesion on the paper substrate. The surface topography and chemical bonding of the proposed CG-f@MWCNT …


Effects Of Pulse Width On He Plasma Jets In Contact With Water Evaluated By Oh(A-X) Emission And Ohaq Production, Shutong Song, Esin B. Sözer, Chunqi Jiang Jun 2019

Effects Of Pulse Width On He Plasma Jets In Contact With Water Evaluated By Oh(A-X) Emission And Ohaq Production, Shutong Song, Esin B. Sözer, Chunqi Jiang

Bioelectrics Publications

Nanosecond pulsed helium plasma jets impinging on water produce hydroxyl radicals both in gas- and liquid-phase. In this study, the effects of pulse width on a repetitively pulsed plasma jet in contact with water are evaluated via OH(A-X) emission and OHaq production in water for various pulse widths ranging from 200 to 5000 ns. The maximal energy efficiency of OH(A-X) emission is obtained for pulse widths of 600-800 ns whereas the maximal efficiency of OHaq production is at 200 ns. Temporally-resolved emission spectroscopy shows that more than 40% of OH(A-X) emission is produced during the first 200 ns …


Modulation Of Biological Responses To 2 Ns Electrical Stimuli By Field Reversal, Esin B. Sözer, P. Thomas Vernier Jun 2019

Modulation Of Biological Responses To 2 Ns Electrical Stimuli By Field Reversal, Esin B. Sözer, P. Thomas Vernier

Bioelectrics Publications

Nanosecond bipolar pulse cancellation, a recently discovered Phenomenon, is modulation of the effects of a unipolar electric pulse exposure by a second pulse of opposite polarity. This attenuation of biological response by reversal of the electric field direction has been reported with pulse durations from 60 ns to 900 ns for a wide range of endpoints, and it is not observed with conventional electroporation pulses of much longer duration (> 100 mu s) where pulses are additive regardless of polarity. The most plausible proposed mechanisms involve the field-driven migration of ions to and from the membrane interface (accelerated membrane discharge). …


A Fully-Flexible Solution-Processed Autonomous Glucose Indicator, Jonathan D. Yuen, Ankit Baingane, Qumrul Hasan, Lisa C. Shriver-Lake, Scott A. Walper, Daniel Zabetakis, Joyce C. Breger, David A. Stenger, Gymama Slaughter Jan 2019

A Fully-Flexible Solution-Processed Autonomous Glucose Indicator, Jonathan D. Yuen, Ankit Baingane, Qumrul Hasan, Lisa C. Shriver-Lake, Scott A. Walper, Daniel Zabetakis, Joyce C. Breger, David A. Stenger, Gymama Slaughter

Bioelectrics Publications

We present the first demonstration of a fully-flexible, self-powered glucose indicator system that synergizes two flexible electronic technologies: a flexible self-powering unit in the form of a biofuel cell, with a flexible electronic device - a circuit-board decal fabricated with biocompatible microbial nanocellulose. Our proof-of-concept device, comprising an enzymatic glucose fuel cell, glucose sensor and a LED indicator, does not require additional electronic equipment for detection or verification; and the entire structure collapses into a microns-thin, self-adhering, single-centimeter-square decal, weighing less than 40 mg. The flexible glucose indicator system continuously operates a light emitting diode (LED) through a capacitive charge/discharge …


Effect Of Cold Atmospheric Plasma Treatment On The Metabolites Of Human Leukemia Cells, Dehui Xu, Ning Ning, Yujing Xu, Bingchuan Wang, Qingjie Cui, Zhijie Liu, Xiaohua Wang, Dingxin Liu, Hailan Chen, Michael G. Kong Jan 2019

Effect Of Cold Atmospheric Plasma Treatment On The Metabolites Of Human Leukemia Cells, Dehui Xu, Ning Ning, Yujing Xu, Bingchuan Wang, Qingjie Cui, Zhijie Liu, Xiaohua Wang, Dingxin Liu, Hailan Chen, Michael G. Kong

Bioelectrics Publications

Background

Acute myeloid leukemia (AML) is a typically fatal malignancy and new drug and treatment need to be developed for a better survival outcome. Cold atmospheric plasma (CAP) is a novel technology, which has been widely applied in biomedicine, especially in various of cancer treatment. However, the changes in cell metabolism after CAP treatment of leukemia cells have been rarely studied.

Methods

In this study, we investigated the metabolite profiling of plasma treatment on leukemia cells based on Gas Chromatography Tandem Time-of-Flight Mass Spectrometry (GC-TOFMS). Simultaneously, we conducted a series of bioinformatics analysis of metabolites and metabolic pathways with significant …


Intratumoral Delivery Of Plasmid Il12 Via Electroporation Leads To Regression Of Injected And Noninjected Tumors In Merkel Cell Carcinoma, Shailender Bhatia, Natalie V. Longino, Natalie J. Miller, Rima Kulikauskas, Jayasri G. Iyer, Dafina Ibrani, Astrid Blom, David R. Byrd, Upendra Parvathaneni, Christopher Twitty, Jean S. Campbell, Mai H. Le, Sharron Gargosky, Robert H. Pierce, Richard Heller, Adil Daud, Paul Nghiem Jan 2019

Intratumoral Delivery Of Plasmid Il12 Via Electroporation Leads To Regression Of Injected And Noninjected Tumors In Merkel Cell Carcinoma, Shailender Bhatia, Natalie V. Longino, Natalie J. Miller, Rima Kulikauskas, Jayasri G. Iyer, Dafina Ibrani, Astrid Blom, David R. Byrd, Upendra Parvathaneni, Christopher Twitty, Jean S. Campbell, Mai H. Le, Sharron Gargosky, Robert H. Pierce, Richard Heller, Adil Daud, Paul Nghiem

Bioelectrics Publications

Purpose: Interleukin-12 (IL12) promotes adaptive type I immunity and has demonstrated antitumor efficacy, but systemic administration leads to severe adverse events (AE), including death. This pilot trial investigated safety, efficacy, and immunologic activity of intratumoral delivery of IL12 plasmid DNA (tavo) via in vivo electroporation (i.t.-tavo-EP) in patients with Merkel cell carcinoma (MCC), an aggressive virus-associated skin cancer.

Experimental Design: Fifteen patients with MCC with superficial injectable tumor(s) received i.t.-tavo-EP on days 1, 5, and 8 of each cycle. Patients with locoregional MCC (cohort A, N = 3) received one cycle before definitive surgery in week 4. …


Special Collection On Electroporation-Based Therapies: A Selection Of Papers From The Second World Congress On Electroporation, Richard Heller, Rafael V. Davalos Jan 2019

Special Collection On Electroporation-Based Therapies: A Selection Of Papers From The Second World Congress On Electroporation, Richard Heller, Rafael V. Davalos

Bioelectrics Publications

No abstract provided.


Quantifying The Concentration And Penetration Depth Of Long-Lived Rons In Plasma Activated Water By Uv Absorption Spectroscopy, Zhijie Liu, Chunxi Zhou, Dingxin Liu, Tongtong He, Li Guo, Dehui Xu, Michael G. Kong Jan 2019

Quantifying The Concentration And Penetration Depth Of Long-Lived Rons In Plasma Activated Water By Uv Absorption Spectroscopy, Zhijie Liu, Chunxi Zhou, Dingxin Liu, Tongtong He, Li Guo, Dehui Xu, Michael G. Kong

Bioelectrics Publications

Reactive oxygen and reactive nitrogen species (RONS) are believed to play a key role in biomedical applications, which means that RONS must reach the target tissue to produce a therapeutic effect. Existing methods (electron spin spectrometry and microplate reading) to determine the RONS concentration are not suitable for experimental real-time measurements because they require adding an indicating reagent to the plasma-treated medium, which may alter the chemical composition of the medium. In this paper, we propose a method to measure the long-lived RONS concentration in plasma-activated water (PAW) by using UV absorption spectroscopy. Based on an analysis and fit of …


Selective Distant Electrostimulation By Synchronized Bipolar Nanosecond Pulses, Elena C. Gianulis, Maura Casciola, Carol Zhou, Enbo Yang, Shu Xiao, Andrei G. Pakhomov Jan 2019

Selective Distant Electrostimulation By Synchronized Bipolar Nanosecond Pulses, Elena C. Gianulis, Maura Casciola, Carol Zhou, Enbo Yang, Shu Xiao, Andrei G. Pakhomov

Bioelectrics Publications

A unique aspect of electrostimulation (ES) with nanosecond electric pulses (nsEP) is the inhibition of effects when the polarity is reversed. This bipolar cancellation feature makes bipolar nsEP less efficient at biostimulation than unipolar nsEP. We propose to minimize stimulation near pulse-delivering electrodes by applying bipolar nsEP, whereas the superposition of two phase-shifted bipolar nsEP from two independent sources yields a biologically-effective unipolar pulse remotely. This is accomplished by electrical compensation of all nsEP phases except the first one, resulting in the restoration of stimulation efficiency due to cancellation of bipolar cancellation (CANCAN-ES). We experimentally proved the CANCAN-ES paradigm by …


Nanosecond Pulsed Electric Signals Can Affect Electrostatic Environment Of Protiens Below The Threshold Of Conformational Effects: The Case Study Of Sod1 With A Molecular Simulation Study, Elena Della Valle, Paolo Marracino, Olga Pakhomova, Micaela Liberti, Francesca Apollonio Jan 2019

Nanosecond Pulsed Electric Signals Can Affect Electrostatic Environment Of Protiens Below The Threshold Of Conformational Effects: The Case Study Of Sod1 With A Molecular Simulation Study, Elena Della Valle, Paolo Marracino, Olga Pakhomova, Micaela Liberti, Francesca Apollonio

Bioelectrics Publications

Electric fields can be a powerful tool to interact with enzymes or proteins, with an intriguing perspective to allow protein manipulation. Recently, researchers have focused the interest on intracellular enzyme modifications triggered by the application of nanosecond pulsed electric fields. These findings were also supported by theoretical predictions from molecular dynamics simulations focussing on significant variations in protein secondary structures. In this work, a theoretical study utilizing molecular dynamics simulations is proposed to explore effects of electric fields of high intensity and very short nanosecond duration applied to the superoxide dismutase (Cu/Zn-SOD or SOD-1), an important enzyme involved in the …


Nanosecond Pulsed Electric Fields Induce Endoplasmic Reticulum Stress Accompanied By Immunogenic Cell Death In Murine Models Of Lymphoma And Colorectal Cancer, Alessandra Rossi, Olga N. Pakhomova, Peter A. Mollica, Maura Casciola, Uma Mangalanathan, Andrei G. Pakhomov, Claudia Muratori Jan 2019

Nanosecond Pulsed Electric Fields Induce Endoplasmic Reticulum Stress Accompanied By Immunogenic Cell Death In Murine Models Of Lymphoma And Colorectal Cancer, Alessandra Rossi, Olga N. Pakhomova, Peter A. Mollica, Maura Casciola, Uma Mangalanathan, Andrei G. Pakhomov, Claudia Muratori

Bioelectrics Publications

Depending on the initiating stimulus, cancer cell death can be immunogenic or non-immunogenic. Inducers of immunogenic cell death (ICD) rely on endoplasmic reticulum (ER) stress for the trafficking of danger signals such as calreticulin (CRT) and ATP. We found that nanosecond pulsed electric fields (nsPEF), an emerging new modality for tumor ablation, cause the activation of the ER-resident stress sensor PERK in both CT-26 colon carcinoma and EL-4 lymphoma cells. PERK activation correlates with sustained CRT exposure on the cell plasma membrane and apoptosis induction in both nsPEF-treated cell lines. Our results show that, in CT-26 cells, the activity of …


Mechanisms And Immunogenicity Of Nspef-Induced Cell Death In B16f10 Melanoma Tumors, Alessandra Rossi, Olga N. Pakhomova, Andrei G. Pakhomov, Samantha Weygandt, Anna A. Bulysheva, Len E. Murray, Peter A. Mollica, Claudia Muratori Jan 2019

Mechanisms And Immunogenicity Of Nspef-Induced Cell Death In B16f10 Melanoma Tumors, Alessandra Rossi, Olga N. Pakhomova, Andrei G. Pakhomov, Samantha Weygandt, Anna A. Bulysheva, Len E. Murray, Peter A. Mollica, Claudia Muratori

Bioelectrics Publications

Accumulating data indicates that some cancer treatments can restore anticancer immunosurveillance through the induction of tumor immunogenic cell death (ICD). Nanosecond pulsed electric fields (nsPEF) have been shown to efficiently ablate melanoma tumors. In this study we investigated the mechanisms and immunogenicity of nsPEF-induced cell death in B16F10 melanoma tumors. Our data show that in vitro nsPEF (20-200, 200-ns pulses, 7 kV/cm, 2 Hz) caused a rapid dose-dependent cell death which was not accompanied by caspase activation or PARP cleavage. The lack of nsPEF-induced apoptosis was confirmed in vivo in B16F10 tumors. NsPEF also failed to trigger ICD-linked responses such …