(Bi0.51 Na0.47)Tio3 Based Lead Free Ceramics With High Energy Density And Efficiency, Yu Huang, Fei Li, Hua Hao, Fangquan Xia, Hanxing Liu, Shujun Zhang Jan 2019

(Bi0.51 Na0.47)Tio3 Based Lead Free Ceramics With High Energy Density And Efficiency, Yu Huang, Fei Li, Hua Hao, Fangquan Xia, Hanxing Liu, Shujun Zhang

Australian Institute for Innovative Materials - Papers

Dielectric ceramics with high energy storage density and energy efficiency play an important role in high power energy storage applications. In this work, lead free relaxor ferroelectric ceramics in (1-x)Bi 0.51 Na 0.47 TiO 3 - xBa(Zr 0.3 Ti 0.7 )O 3 (BNT-BZT100x: x = 0.20, 0.30, 0.40 and 0.50) system are fabricated by conventional solid-state sintering method. The BNT-BZT100x ceramics are sintered dense with minimal pores, exhibiting pseudocubic symmetry and strong relaxor characteristic. A high energy storage density of 3.1 J/cm 3 and high energy efficiency of 91% are simultaneously achieved in BNT-BZT40 ceramic with 0.1 mm in thickness, …


Ultrasonic Spray Deposition Of Tio2 Electron Transport Layers For Reproducible And High Efficiency Hybrid Perovskite Solar Cells, Jingsong Sun, Alexander Pascoe, Steffen Meyer, Qijie Wu, Enrico Della Gaspera, Sonia Raga, Tian Zhang, Andrew Nattestad, Udo Bach, Yi-Bing Cheng, Jacek Jasieniak Jan 2019

Ultrasonic Spray Deposition Of Tio2 Electron Transport Layers For Reproducible And High Efficiency Hybrid Perovskite Solar Cells, Jingsong Sun, Alexander Pascoe, Steffen Meyer, Qijie Wu, Enrico Della Gaspera, Sonia Raga, Tian Zhang, Andrew Nattestad, Udo Bach, Yi-Bing Cheng, Jacek Jasieniak

Australian Institute for Innovative Materials - Papers

The fabrication of high efficiency perovskite solar cells at larger scales will rely on the optimized deposition conditions of every layer using scalable methodologies. Most current perovskite devices that employ the archetypal TiO2 hole blocking layer utilise a simple air-brush approach. This approach is not scalable as it results in significant layer inhomogeneity across larger devices areas. To overcome this inherent limitation, in this work we use ultrasonic spray deposition as an alternative approach for the TiO2 deposition. Focusing on identical reaction chemistries as for air-brush, namely bis(isopropoxide)-bis(acetylacetonate) titanium (IV) based solutions, we find that under optimized conditions smooth TiO2 …


Flexible And Free-Standing Siox/Cnt Compositefilms For High Capacityand Durable Lithium Ion Batteries, Wenlei Guo, Xiao Yan, Feng Hou, Lei Wen, Yejing Dai, Deming Yang, Xiaotong Jiang, Jian Liu, Ji Liang, Shi Xue Dou Jan 2019

Flexible And Free-Standing Siox/Cnt Compositefilms For High Capacityand Durable Lithium Ion Batteries, Wenlei Guo, Xiao Yan, Feng Hou, Lei Wen, Yejing Dai, Deming Yang, Xiaotong Jiang, Jian Liu, Ji Liang, Shi Xue Dou

Australian Institute for Innovative Materials - Papers

Flexible and free-standing electrode materials are prerequisite and key components for next-generation flexible energy storage and conversion devices. However, it is still a chanllenge to fabricate these materials from a continuous, straightforward, and facile method. Herein, we report a flexible composite film with silicon oxides decorated on few-walled carbon nanotubes, which can be continuously fabricated and directly drawn from the hot zone of the reactor. The composite film can be readily used for electrochemical lithium ion storage with high and reversible specific capacity, good rate capability, and excellent cycling performance. These exceptional characteristics make it very promising for flexible energy …


Local-Global Interaction Buckling Of Square High Strength Concrete-Filled Double Steel Tubular Slender Beam-Columns, Mizen Ahmed, Qing Quan Liang, Vipulkumar I. Patel, Muhammad N. S Hadi Jan 2019

Local-Global Interaction Buckling Of Square High Strength Concrete-Filled Double Steel Tubular Slender Beam-Columns, Mizen Ahmed, Qing Quan Liang, Vipulkumar I. Patel, Muhammad N. S Hadi

Faculty of Engineering and Information Sciences - Papers: Part B

High-strength square concrete-filled double steel tubular (CFDST) slender beam-columns with a circular internal steel tube subjected to eccentric loads may undergo interaction local-global buckling. No computational studies on the interaction local-global buckling of slender square CFDST beam-columns have been reported and their behavior has not been fully understood. This paper describes a mathematical model for the simulation of the interaction local-global buckling behavior of square high-strength CFDST slender beam-columns under axial compression in combination with uniaxial bending. The mathematical model is formulated by the fiber approach, accounting for confinement provided by the internal circular steel tube, and geometric and material …


Investigation Of Engineering Properties Of Normal And High Strength Fly Ash Based Geopolymer And Alkali-Activated Slag Concrete Compared To Ordinary Portland Cement Concrete, Nabeel Farhan, M Neaz Sheikh, Muhammad N. S Hadi Jan 2019

Investigation Of Engineering Properties Of Normal And High Strength Fly Ash Based Geopolymer And Alkali-Activated Slag Concrete Compared To Ordinary Portland Cement Concrete, Nabeel Farhan, M Neaz Sheikh, Muhammad N. S Hadi

Faculty of Engineering and Information Sciences - Papers: Part B

Fly ash-based geopolymer (FAGP) and alkali-activated slag (AAS) concrete are produced by mixing alkaline solutions with aluminosilicate materials. As the FAGP and AAS concrete are free of Portland cement, they have a low carbon footprint and consume low energy during the production process. This paper compares the engineering properties of normal strength and high strength FAGP and AAS concrete with OPC concrete. The engineering properties considered in this study included workability, dry density, ultrasonic pulse velocity (UPV), compressive strength, indirect tensile strength, flexural strength, direct tensile strength, and stress-strain behaviour in compression and direct tension. Microstructural observations using scanning electronic …


Numerical Analysis Of Axially Loaded Circular High Strength Concrete-Filled Double Steel Tubular Short Columns, Mizen Ahmed, Qing Quan Liang, Vipulkumar I. Patel, Muhammad N. S Hadi Jan 2019

Numerical Analysis Of Axially Loaded Circular High Strength Concrete-Filled Double Steel Tubular Short Columns, Mizen Ahmed, Qing Quan Liang, Vipulkumar I. Patel, Muhammad N. S Hadi

Faculty of Engineering and Information Sciences - Papers: Part B

Circular high-strength concrete-filled double steel tubular (CFDST) columns are high performance members where the internal and external steel tubes offer significant confinement to the concrete infill. The confinement remarkably improves the concrete compressive strength and ductility. However, no fiber element models have been formulated for computing the responses of CFDST columns with circular steel tubes filled with high-strength concrete incorporating accurate confinement to the core and sandwiched concrete. In this paper, a new fiber-based numerical model is developed that computes the axial load-strain responses of circular high-strength CFDST short columns under axial loading. Based on existing experimental results, a new …


The Rapid Chemically Induced Corrosion Of Concrete Sewers At High H2s Concentration, Xuan Li, Liza O'Moore, Yarong Song, Philp Bond, Zhiguo Yuan, Simeon Wilkie, Lucija Hanzic, Guangming Jiang Jan 2019

The Rapid Chemically Induced Corrosion Of Concrete Sewers At High H2s Concentration, Xuan Li, Liza O'Moore, Yarong Song, Philp Bond, Zhiguo Yuan, Simeon Wilkie, Lucija Hanzic, Guangming Jiang

Faculty of Engineering and Information Sciences - Papers: Part B

Concrete corrosion in sewers is primarily caused by H2S in sewer atmosphere. H2S concentration can vary from several ppm to hundreds of ppm in real sewers. Our understanding of sewer corrosion has increased dramatically in recent years, however, there is limited knowledge of the concrete corrosion at high H2S levels. This study examined the corrosion development in sewers with high H2S concentrations. Fresh concrete coupons, manufactured according to sewer pipe standards, were exposed to corrosive conditions in a pilot-scale gravity sewer system with gaseous H2S at 1100 ± 100 ppm. The corrosion process was continuously monitored by measuring the surface …