Full-Text Articles in Engineering

Seismic Design Coefficients For Speedcore Or Composite Plate Shear Walls - Concrete Filled (C-Psw/Cf), Shubham Agrawal, Morgan Broberg, Amit H. Varma Aug 2020

Seismic Design Coefficients For Speedcore Or Composite Plate Shear Walls - Concrete Filled (C-Psw/Cf), Shubham Agrawal, Morgan Broberg, Amit H. Varma

Bowen Laboratory Research Reports

This report summarizes the results from FEMA P695 analytical studies conducted to verify the seismic design factors for composite plate shear walls – concrete filled (C-PSW/CF), also referred to as Speedcore. ASCE 7-16 provides the seismic design factors, which include the seismic response modification factor, R, deflection amplification factor, Cd, and overstrength factor, Ωo, for various approved seismic systems. C-PSW/CFs are assigned a response modification factor of 6.5, a deflection amplification factor of 5.5, and an overstrength factor of 2.5 for C-PSW/CFs. These seismic design factors were selected based on the seismic performance of similar structural …