Behavior Of Fire-Exposed Rc Frames Before And After Jacketing, M. Monir M. Ajan Alhadid Oct 2016

Behavior Of Fire-Exposed Rc Frames Before And After Jacketing, M. Monir M. Ajan Alhadid

Electronic Thesis and Dissertation Repository

Analysis and design of fire-exposed Reinforced Concrete (RC) frames before and after jacketing with concrete layers are commonly performed using prescriptive methods that rely on the concept of fire rating. These methods were developed based on empirical results on individual RC members subjected to certain fire conditions. In typical fire scenarios, the residual capacity, stiffness and thermal deformations affects not only the local performance of each fire-exposed member, but also the load redistribution and global behavior of the entire frame. In terms of fire safety, the philosophy of the new building codes considers objective-based design as an alternative of the …


Temperature And Strain Measurements With Fiber Optic Sensors For Steel Beams Subjected To Fire, Yi Bao, Yizheng Chen, Matthew S. Hoehler, Christopher M. Smith, Matthew F. Bundy, Genda Chen Jun 2016

Temperature And Strain Measurements With Fiber Optic Sensors For Steel Beams Subjected To Fire, Yi Bao, Yizheng Chen, Matthew S. Hoehler, Christopher M. Smith, Matthew F. Bundy, Genda Chen

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

This paper presents measurements of high temperatures using a Brillouin scattering based fiber optic sensor and large strains using an extrinsic Fabry-Perot interferometric sensor for assessing the thermo-mechanical behaviors of simply supported steel beams subjected to combined thermal and mechanical loading. The distributed fiber optic sensor captures detailed, non- uniform temperature distributions that are compared with thermocouple measurements resulting in an average relative difference of less than 5 % at 95 % confidence level. The extrinsic Fabry- Perot interferometric sensor captures large strains at temperatures above 1000 C. The strain results measured from the distributed fiber optic sensors and extrinsic …