Power Quality Emission Assessment Of Photovoltaic Inverters Based On Iec Technical Report 61000-3-15:2011, Devinda Perera, Philip Ciufo, Lasantha G. Meegahapola, Sarath Perera Apr 2015

Power Quality Emission Assessment Of Photovoltaic Inverters Based On Iec Technical Report 61000-3-15:2011, Devinda Perera, Philip Ciufo, Lasantha G. Meegahapola, Sarath Perera

Dr Philip Ciufo

The International Electrotechnical Committee Technical Report IEC 61000-3-15:2011 provides electromagnetic compatibility requirements and test conditions for distributed generators up to 75 A per phase. In the current research, two commercially available photovoltaic (PV) inverters up to the capacity of 3600 W were tested following the guidelines proposed in IEC 61000-3-15 in relation to low order harmonic emission and flicker emission. In addition, the harmonic and flicker emission behaviour of the PV inverters were investigated under varying irradiation conditions. Both PV inverters were observed to comply with the emission requirements prescribed by the technical report under most conditions except for even …


Voltage Unbalance Emission Assessment: Sources Of Contribution And Their Ranking, U Jayatunga, Sarath Perera, P Ciufo, A P. Agalgaonkar Apr 2015

Voltage Unbalance Emission Assessment: Sources Of Contribution And Their Ranking, U Jayatunga, Sarath Perera, P Ciufo, A P. Agalgaonkar

Dr Philip Ciufo

etermining sources of voltage unbalance (VU) and quantifying their individual contributions in an interconnected network is a complex task due to multiple interactions that take place between them. Post-connection VU emission assessment techniques in relation to customer installations are important not only in compliance assessment according to IEC/TR 61000-3- 13:2008 Limits - Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems, but also in determining the various emission contributors in the power system being considered. This paper presents a case study on the application of a recently developed post-connection VU emission assessment …


A Phantom Assessment Of Achievable Contouring Concordance Across Multiple Treatment Planning Systems, Elise M. Pogson, Jarrad Begg, Michael Jameson, Claire Dempsey, Drew Latty, Vikneswary Batumalai, Andrew Lim, Kankean Kandasamy, Peter E. Metcalfe, Lois C. Holloway Jan 2015

A Phantom Assessment Of Achievable Contouring Concordance Across Multiple Treatment Planning Systems, Elise M. Pogson, Jarrad Begg, Michael Jameson, Claire Dempsey, Drew Latty, Vikneswary Batumalai, Andrew Lim, Kankean Kandasamy, Peter E. Metcalfe, Lois C. Holloway

Faculty of Engineering and Information Sciences - Papers: Part A

In this paper, the highest level of inter- and intra-observer conformity achievable with different treatment planning systems (TPSs), contouring tools, shapes, and sites have been established for metrics including the Dice similarity coefficient (DICE) and Hausdorff Distance. High conformity values, e.g. DICEBreast_Shape = 0.99 ± 0.01, were achieved. Decreasing image resolution decreased contouring conformity.


Urinary Continence Care In Australian Nursing Homes, Ping Yu, Victoria Traynor, David Hailey Jan 2015

Urinary Continence Care In Australian Nursing Homes, Ping Yu, Victoria Traynor, David Hailey

Faculty of Engineering and Information Sciences - Papers: Part A

Objective Exploring urinary continence (UC) assessment and management practices in Australian nursing homes. Design Mixed method using a questionnaire and interviews. Setting Five nursing homes in Australian metropolitan cities. Subjects Participants 121 staff: mostly female (91%) with a range of roles including personal care assistants (PCAs) (63%), enrolled nurses (ENs) (11%), registered nurses (RNs) (20%) and managers (4%). Main outcomes measure(s) Compliance with and perceptions about UC assessment and management. Results 77% (n=71) of care staff (PCAs, ENs and RNs) were compliant with the UC management protocol of checking for wetness every 2 to 2.5 hours. Toileting time and frequency …


An Assessment Of Image Distortion And Ct Number Accuracy Within A Wide-Bore Ct Extended Field Of View, Bradley Beeksma, D Truant, Lois C. Holloway, Sankar Arumugam Jan 2015

An Assessment Of Image Distortion And Ct Number Accuracy Within A Wide-Bore Ct Extended Field Of View, Bradley Beeksma, D Truant, Lois C. Holloway, Sankar Arumugam

Faculty of Engineering and Information Sciences - Papers: Part A

Although wide bore computed tomography (CT) scanners provide increased space for patients, the scan field of view (sFOV) remains considerably smaller than the bore size. Consequently, patient anatomy which spans beyond the sFOV is truncated and the information is lost. As a solution, some manufacturers provide the capacity to reconstruct CT images from a partial dataset at an extended field of view (eFOV). To assess spatial distortion within this eFOV three phantoms were considered a 30 x 30 x 20 cm3 slab of solid water, the Gammex electron density CT phantom and a female anthropomorphic phantom. For each phantom, …


A Refined General Summation Law For Vu Emission Assessment In Radial Networks, Jayatunga Vitharanage Upuli Priyadarshani Jayatunga, Sarath Perera, Philip Ciufo, Ashish P. Agalgaonkar Jan 2015

A Refined General Summation Law For Vu Emission Assessment In Radial Networks, Jayatunga Vitharanage Upuli Priyadarshani Jayatunga, Sarath Perera, Philip Ciufo, Ashish P. Agalgaonkar

Faculty of Engineering and Information Sciences - Papers: Part A

Voltage unbalance (VU) management of power systems requires the development of well researched engineering practices to maintain acceptable VU levels while utilising the total VU absorption capacity of the power system. In this regard, IEC/TR 61000-3-13:2008 prescribes a VU emission allocation methodology based on a stochastic approach which uses a general summation law in order to aggregate numerous sources of unbalance to take into account their random variations. On the other hand, recent deterministic studies on VU emission assessment at the post-connection stage of unbalanced installations present a complex VU factor based approach to determine constituent components of the post-connection …


Dce-Mri For Pre-Treatment Prediction And Post-Treatment Assessment Of Treatment Response In Sites Of Squamous Cell Carcinoma In The Head And Neck, Ann D. King, Steven Kwok Keung Chow, Kwok-Hung Yu, Frankie Kwok Fai Mo, David K. W. Yeung, Jing Yuan, Benjamin King Hong Law, Kunwar S. Bhatia, Alexander C. Vlantis, Anil T. Ahuja Jan 2015

Dce-Mri For Pre-Treatment Prediction And Post-Treatment Assessment Of Treatment Response In Sites Of Squamous Cell Carcinoma In The Head And Neck, Ann D. King, Steven Kwok Keung Chow, Kwok-Hung Yu, Frankie Kwok Fai Mo, David K. W. Yeung, Jing Yuan, Benjamin King Hong Law, Kunwar S. Bhatia, Alexander C. Vlantis, Anil T. Ahuja

Faculty of Engineering and Information Sciences - Papers: Part A

Background and Purpose It is important to identify patients with head and neck squamous cell carcinoma (SCC) who fail to respond to chemoradiotherapy so that they can undergo post-treatment salvage surgery while the disease is still operable. This study aimed to determine the diagnostic performance of dynamic contrast enhanced (DCE)-MRI using a pharmacokinetic model for pre-treatment predictive imaging, as well as post-treatment diagnosis, of residual SCC at primary and nodal sites in the head and neck. Material and Methods Forty-nine patients with 83 SCC sites (primary and/or nodal) underwent pre-treatment DCEMRI, and 43 patients underwent post-treatment DCE-MRI, of which 33 …